PercepxiON · Studies

Sixteen buildings, studied

Sixteen real public buildings, read from their published plans with the studio's own tools. Each was chosen because it was never designed to pass the method, which makes it the fairest test of where the method holds.

Why read them

A model tested only on its own clients agrees with itself. Buildings that were never designed to pass it show where it holds and where it breaks.

← All sixteen buildings

01 · INDEPENDENT STUDYSagrada Família

A basilica built around coloured light. Read side by side, its two halves differ in winter sun, not in colour: the warm side keeps its daylight, the cool side barely gets enough.

Antoni Gaudí1882 ONWARDS · NAVE CONSECRATED 2010
Barcelona · 41.40°NCATALONIA · OPEN, TICKETED
WorshipBUILDING TYPE · SETS THE WEIGHTS
Built, and still buildingREAD AS BUILT · NOTHING PROPOSED
4 zonesTHE NAVE TWICE, FOR ITS TWO GLASSES

Open the basilica in the reading tool →Loads the four zones as read here. The colour reading will not move; finding 1 is why. · See the building → · Wikipedia →

The nave vault: branching columns opening into the star-shaped ceilingimages/research-sagrada-vault.jpg · 1920 × 1080Credit: Julian Lupyan, CC0
Photograph: Julian Lupyan, CC0, via Wikimedia Commons
The vault the columns branch into, lit through the coloured glass, cool on the Nativity side and warm on the Passion side. This is the condition the colour model does not read yet.

What the numbers stand on

The geometry is published to the metre and the glass is published as a scheme, not as a spectrum, which is the gap finding 1 sits in.

KNOWN · PUBLISHED

  • Nave about 90 m long and 45 m across five aisles; central nave 45 m high, side aisles 30 m, the crossing vault 60 m
  • Capacity about 9,000; columns of granite, basalt, porphyry and Montjuïc sandstone, graded by the load each carries
  • Stained glass by Joan Vila-Grau, 1999 onwards: greens and blues on the Nativity side, east; reds and oranges on the Passion side, west
  • Stone floor; hyperboloid vaults pierced with lit crowns; Gaudí's crypt of 1882 to 1891 beneath the apse

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The nave read as two halves of 22.5 × 45 m, entrance to crossing, so each half faces one glass, which is the only way to get two colour readings out of one room
  • Glazed fraction of the aisle wall taken as 0.45, from elevations; 0.25 at the crossing
  • Occupancy: 800 a side at a normal visiting hour, 600 at the crossing, 40 in the crypt
  • The crypt taken as 25 × 25 × 9 with a tenth of one wall to its light moat

MAPPED · AND WHAT THE TOOL LACKS

  • Stone vault → concrete for absorption; Montjuïc stone → lime, and cream for colour; pews → oak at the hand
  • Coloured light. There is no term for it. The colour model multiplies a wall pigment by a lamp, and this building colours the light before it lands. Finding 1
  • The vault as a box. Volume is read as 22.5 × 45 × 45, well over the true hyperboloid, so the sound reading is a ceiling and not a measurement
  • Lit crowns. The vault crowns are rooflights, and the tool cannot see one. It is the first of four buildings on this page where that matters

Research card

Study 01 · Read

Problem
Vila-Grau's glass is cool on the Nativity side and warm on the Passion side, and visitors describe the two halves as different rooms.
Question

Does the coloured glass make the two halves of the nave measurably different rooms?

Method and analysis
Method
The nave split down its axis into two identical halves, one facing each glass, plus the crossing and the crypt. Six models, weighted for worship.
Analysis
Compared: Orientation and glass colour. Stone, height, pews and crowd held identical. Measured: Circadian dose by side, reverberation, ceiling-to-body ratio, colour, material and view.
Finding
Colour reads 44 on both sides: the model multiplies a pigment by a lamp and cannot see coloured daylight. The difference a body can measure is the sun: the warm side holds its winter daylight, the cool side is marginal.
Design implication
Glass colour and orientation have to be read together. The next model to build is a seventh input: the spectrum of the light arriving.

THE ZONESOne nave, read twice

The reading splits the nave down its axis so that each half faces one glass. Everything else about the two halves is identical: same stone, same floor, same height, same pews, same crowd. Any difference the tool returns between them is a difference the glass made, and that is the experiment. The section is drawn to scale across the nave; the plan is schematic, turned so that it reads the same way round.

The nave cut across, looking towards the Glory façade, to scale. Tree columns fork to carry the side vaults at 30 m and the central vault at 45 m, each bay with a lit crown. Cool glass on the Nativity side, warm on the Passion side, both falling on the same stone, and the tool gives both halves the same colour reading. The figure is the median adult, 1.685 m.
Schematic plan, south-east at the top of the page so the Nativity side is on the left, as in the section. Dashed boxes are the zones as read. The side walls face north-east and south-west, on the boundary between two of the tool's cardinals, which is why finding 4 is a range.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Nave, Nativity sideGather22.5 × 45 × 45north-east, read as east, 45% · citystone vault · stone · stoneoak pewcream · 3000 K
Nave, Passion sideGather22.5 × 45 × 45south-west, read as west, 45% · citystone vault · stone · stoneoak pewcream · 3000 K
The crossingGather45 × 30 × 60south, 25% · skystone vault · stone · stoneoak pewcream · 3000 K
Gaudí's cryptRest25 × 25 × 9south, 10% · blankstone vault · stone · stoneoak pewbeige · 2700 K

Heights are taken at the crown, which the Kimbell reading shows to be the wrong line for a body. Sagrada Família has the same two-height problem at nine times the size. The Eixample grid sits about 45° off north, so the aisle walls face north-east and south-west, exactly between two of the tool's four cardinals; finding 4 reads them both ways.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for worship. The two nave halves come back identical on five of six, and the one that moves is not the one you would expect.

WHAT THE READING FOUNDFive things about a building made of coloured light

144 · 44colour reading, Nativity side · Passion side
6–96 scale · identical
the open case

The building's colour lives in its light, and that writes the brief for the next colour model.

Vila-Grau's glass is cool on the east and warm on the west, and every visitor who has walked from one side to the other in an afternoon can tell you the two halves are different rooms. The tool returns 44 for both. It is not a rounding. The colour model multiplies a wall pigment by a lamp temperature, which is the right arithmetic for a painted room under a bulb, and this building colours the light before it reaches any pigment at all. The term does not exist to be wrong.

This is the most useful result in the set, because it is specific enough to build. A seventh input, the spectrum of the light arriving rather than the temperature of the lamp emitting, would read stained glass, coloured film, a green courtyard and a red brick lightwell with the same model. Until it exists, the studio's rule is to say so on the face of the reading rather than publish 44 as though it meant something.

GENERATED FROM pigment × illuminant · affect model fitted to two studies · dimension 06 · the coloured-light case is not in the tool
210.55sreverberation in half the nave, 800 people
17.15 s at the crossing · target 0.6–0.9 s
upper bound

Ten and a half seconds in the nave, seventeen at the crossing, and both are ceilings.

Sabine on 45,600 m³ of stone gives ten and a half seconds for each half of the nave; the crossing, read as a 60 m box, gives seventeen. The real figures should sit lower, for three reasons that all run the same way: the hyperboloid vaults scatter where a box reflects, the columns break the field, and the tool counts the crowd only as bodies in a number rather than as the largest absorber in the room. So the figure is an upper bound and is labelled one.

What the number does say honestly is the shape of the problem. A basilica is the one building type where a very long reverberation is part of the brief for one use, singing, and fatal to another, speech, and the tool has a single target for both. That is the second specification this building writes.

GENERATED FROM Sabine T60 on the stated finishes and volume · dimension 02
326.7 · 35.6nave height ÷ body · crossing ÷ body
comfortable ratio 1.55
72 · 72

Above about four body-heights, every vault reads as the same generous hall.

Forty-five metres is 26.7 median bodies stacked; the crossing is 35.6. Both come back 72, scored as a hall with an abstract prime. So does the Kimbell vault, at 3.6 bodies. The scale model stops distinguishing somewhere around four and returns the same figure for a gallery vault, a cathedral nave and a crossing eight storeys taller than the nave.

That is defensible as far as it goes, since the research the model rests on measured rooms, not cathedrals, and refusing to extrapolate is the honest move. It is worth saying out loud rather than leaving in the number: 72 here does not mean the crossing is as generous as a museum vault, it means the model declined to have an opinion and said so in the only vocabulary it has.

GENERATED FROM body-scaled ratio swept over 64 adult statures · cathedral-effect prime · dimension 09
40.17–0.32 · 0.42–0.63December circadian dose, Nativity side · Passion side
read both ways at the 45° boundary · threshold 0.30
one side holds

The warm side has daylight enough. The cool side is marginal in December.

The Eixample grid runs about 45° off north, so the nave's side walls face north-east and south-west, exactly on the boundary between two of the tool's four cardinals. Its own notes say to read a wall like that both ways, and this is what comes back for December, averaged across the working day: the Passion side reaches 0.42 read as west and 0.63 read as south, clear of the 0.30 a body needs either way. The Nativity side reaches 0.32 read as east and 0.17 read as north. That is the difference between just clearing the threshold and the same winter shortfall the demonstration library has.

So the honest reading is that the cool side is marginal and the warm side is not, and the gap between them is the sun, not the glass. South-west takes the afternoon, and in December the afternoon carries the dose. The one measurable difference the tool found between the two sides of the nave has nothing to do with the colour everyone comes for.

GENERATED FROM solar geometry for 41.40°N, both cardinals either side of the wall's true bearing · circadian stimulus 09:00 to 17:00 · dimension 03
535Gaudí's crypt, total reading
the lowest zone in the basilica
scale 0

The crypt shows why a total should never be read on its own.

The crypt is nine metres high rather than forty-five, and it comes back 35, the lowest of the four. Scale 0 at a ratio of 5.34, sound 10.34 s in a room a tenth the volume of half the nave, view 19 because there is almost nothing to see out of. Every zone above it scores 55 on the strength of a daylight dose and a scale reading that the model admits it cannot resolve.

Read that as a warning about ranking rather than about the crypt. Three of the four zones share a total to within a point because two of their six readings are pinned at their ceilings and two are pinned at zero. When half a reading is at a limit, the total stops being a comparison and becomes an artefact, and this building produces that artefact four times.

GENERATED FROM the four zone readings as run · not adjusted

WHAT I WOULD CHANGENothing, and the refusal is the point

Run the sweep and it proposes 6500 K lamps, heavy planting and textile walls, for a gain of fourteen points. In a UNESCO basilica under a continuing works programme those are not moves, they would harm the building, and the studio refuses them in the same terms it refuses the Kimbell's. The table is printed anyway, because a reading that only shows the moves it likes is not a reading.

ZoneWhat the sweep proposesNowAfter
Nave, either side6500 K lamps · heavy planting · textile walls5567
The crossing6500 K lamps · heavy planting5561
Gaudí's crypt6500 K · planting · slatted ceiling · textile walls3558

Refused, all of it. The one move worth even a conversation is the crypt's lamp temperature, which is reversible and invisible by day, and the studio would want to stand in the room at dusk before saying so. Everything the sweep offers above the crypt line is a generic move, and a protected basilica is exactly where a reading has to know when to stop.

THE LIMITSWhere this reading stops, and what comes next

  • The colour. Finding 1 is not a caveat, it is the headline: on the one thing this building is famous for, the reading has no instrument.
  • The studio has stood in it, but did not measure it. The zones are dimensioned from published figures, and the glass fractions from elevations.
  • The volume. A hyperboloid vault read as a box overstates the air by a long way, and every sound figure moves with it.
  • The crowd. Four and a half million visitors a year are the real absorber and the real noise source, and the tool holds them as a single occupancy number.
  • The building is unfinished. Zone dimensions are as consecrated in 2010; the central towers change the crossing, and this reading predates them.

What it can show is what an instrument does when it meets a building outside its range. It does not fail loudly, it returns a plausible number. Four of these six models returned plausible numbers about the wrong thing, and the only reason you can tell is that the two nave halves came back identical when everyone who has stood in them knows they are not.

16 · INDEPENDENT STUDYThe Barcelona Pavilion

The quietest-looking building in modern architecture. It scores well on light and scale, badly on sound, and the sound problem turns out to be about a curtain.

Mies van der Rohe · Lilly Reich1929 · REBUILT 1986 BY SOLÀ-MORALES, CIRICI, RAMOS
Montjuïc · 41.37°NBARCELONA, OPEN TO THE PUBLIC
GalleryBUILDING TYPE · SETS THE WEIGHTS
BuiltNOTHING CAN MOVE EXCEPT FURNISHINGS
4 zones · 1 routeUNDER A 3.1 M ROOF

Open the pavilion in the reading tool →Loads the four zones exactly as read here. Draw the curtain yourself. · See the building →

The pavilion from the pool, under the 3.1 m roofCredit: buztanki, via Wikimedia Commons (CC BY-SA 3.0)
Photograph: buztanki, via Wikimedia Commons (CC BY-SA 3.0)

What the numbers stand on

A real building read from published sources is only as honest as its inputs, so they are sorted here before anything is computed.

KNOWN · PUBLISHED

  • Plinth 53 × 17 m of Roman travertine, 1.3 m above the street
  • Ceiling 3.1 m, set by the onyx block, split twice and stacked
  • Travertine paving on a 1.1 m module; eight chrome-clad cruciform columns
  • Golden onyx (Atlas), Tinos verde antico, green Alpine marble; grey, green, white and clear glass
  • Red velvet curtain along the glass and a black carpet, both Reich's, recorded in 1929; the curtain is hung in the reconstruction

SCALED · FROM THE PLAN, ±1 M

  • Roofed enclosure about 19 × 12 m
  • Zones: onyx hall 12 × 8, green room 8 × 6, glass passage 3 × 12, annex 4 × 8
  • Large pool about 16 × 9 m; Kolbe court about 11 × 14 m
  • Front glazing faces the avenue, taken as east; the court opening as west

MAPPED · THE TOOL'S VOCABULARY

  • Polished marble → the tool's hardest wall (absorption 0.02, cold surround)
  • Onyx → warm oak; Tinos → deep teal; travertine → beige; white plaster ceiling as itself
  • Daylight-lit → 6500 K; annex electric → 4000 K
  • Chrome and glass at the hand → steel
  • Water has no term in any model here, see the limits

Research card

Study 16 · Read

Problem
Polished marble, onyx, glass and chrome under a 3.1 m roof. Lilly Reich's red velvet curtain and a black carpet were recorded in 1929.
Question

Why does the quietest-looking building in modern architecture sound the way it does?

Method and analysis
Method
Four zones from the published plan on its 1.1 m module. 720 sightlines per point along a 51 m route; image-source reflections in section. Six models, weighted for a gallery.
Analysis
Compared: Curtain open or drawn, carpet laid or not, occupancy. Measured: Reverberation time, early reflections within 10 dB, the onyx in sight along the route, ceiling-to-body ratio.
Finding
5.07 s empty, 3.43 s with twelve people. The curtain and carpet of 1929 bring it to 0.84 s, inside the band.
Design implication
The soft furnishings were part of the acoustic design. A reconstruction without them is a different room.

THE PLANFour zones, one roof, one route

Redrawn from the published plan on the 1.1 m module. The building has no rooms, only planes, so the plan is read the way a visitor reads it: by what is in sight. From any point on the route, 720 sightlines are cast against the stone and the onyx; glass is seen through. Zones are the rectangles the reading tool needs.

Walk the route
Move the walker with the slider, or drag along the strip. Sightlines are cast in plan at eye level, so a stone plane blocks sight and glass does not; the columns are left out. Computed: some part of the onyx is in sight at every half metre of the 51 m walk, from 0.7% of the horizon at the top of the steps to 34% beside it, which is the landmark finding 5 reads by hand. The area in sight falls from about 650 m² on the terrace to 188 m² in the Kolbe court, where green marble fills 62% of the horizon. North is approximate.
Furnish the hall
Section A from the plan, to scale: the onyx on one side, the east glass on the other, a voice and a listener 4.1 m apart. Each line is one reflection path in the plane of the section, found by image sources and drawn as strong as the surfaces it met allow; spreading is left out, so the surfaces are the only variable. The absorption is the reading's own: its Sabine figures imply α 0.03 for the polished surfaces, 0.47 for the drawn velvet and 0.31 for the carpet. As found, 587 arrivals in the first 200 ms are within 10 dB of the voice; in the 1929 state, 159. The T60 is the whole hall's, with twelve people. Figures are the median adult, 1.685 m.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Onyx hallGather12 × 8 × 3.1east, 85%, groundplaster · polished marble · travertinechrome, glassgolden onyx · daylight
Green roomGather8 × 6 × 3.1west to the court, 70%plaster · Tinos marble · travertinechrome, glassdeep green · daylight
Glass passageMove through3 × 12 × 3.1east, 85%plaster · marble · travertinechrome, glasstravertine · daylight
AnnexFocus4 × 8 × 3.1west, 30% · a wallplaster · plaster · travertinesteelwhite · 4000 K

Occupancy for the acoustic reading: twelve in the hall, six in the green room, four in the passage, two in the annex, a quiet afternoon. Empty figures are given where they matter.

THE READINGZone by zone

Six models per zone, weighted for a gallery. The ring is the overall; the bars are light across the year, sound, scale, material, colour under light, and view.

Three readings the tool cannot give, wayfinding, circulation rhythm, the emotional map, are taken from the plan by hand in finding 5, and said to be.

WHAT THE READING FOUNDFive things about a building everyone has seen

15.07sreverberation in the onyx hall, empty
3.43 s with twelve people · target 0.6–0.9 s
0 → 100

It photographs as silence and rings like a swimming pool.

Every surface in the hall is polished stone, glass or chrome; the plaster ceiling is the softest thing in it. Sabine's formula on 298 m³ with fourteen square metres of absorption, most of it people, gives five seconds of tail on every footstep and a clarity index of 8, the one number on this page most visitors would confirm from memory.

Then the curtain. Lilly Reich's red velvet along the east glass is 37 m² of the only absorbent material in the building; drawn, it takes the occupied room to 1.58 s. The black carpet recorded in 1929 takes it to 1.17 s on its own. Together they give 0.84 s, inside the band for a room people gather in. In 1929, with the King in it, the room was acoustically right. What the reconstruction shows with the curtain open is the photograph.

GENERATED FROM Sabine T60 on the stated finishes · curtain and carpet added as 37 m² of velvet and 96 m² of carpet · dimension 02
Onyx hall, twelve peopleT600 – 6 s · the black bracket is the gathering bandSound
As found, curtain open3.430
Curtain drawn1.5859
Carpet laid1.1784
Curtain and carpet · 19290.84100
21.84ceiling ÷ median body
comfortable ratio 1.55 · comfortable for 100% of adults
100

The onyx block set the ceiling; the ceiling sets the mind.

Mies took the height from the stone: one block, split twice, stacked. 3.1 m is above the body-scaled comfortable ratio for every stature in the population sweep, the tallest adult in the model has 1.1 m of air over the head, and it sits at the ratio the ceiling studies associate with abstract rather than concrete thinking. For a room built for a ceremony and now used for looking, that is the right prime, and the model says so without help.

The one place it argues is the annex: the same 3.1 m over a 4 m wide room for focused work reads as a mismatch, because a small room wants a lower sky. Nobody photographs the annex; that is where the mismatch is.

GENERATED FROM population sweep over 64 statures · cathedral-effect prime · dimension 09
368%of the material cost is at the hand
chrome, glass · material 45 · view 34
45

A building for the eye, and it says so to the skin.

Everything the hand can meet in the pavilion is chrome or glass: the columns, the door, the Barcelona chair's frame. On the skin-response integral those are the coldest contacts in the tool, and because the hand returns to them far more often than the eye rests on any one wall, they carry two-thirds of the modelled cost, the same contact-frequency finding as dimension 07, on a building that has no handrail because it needs none.

The eye does no better than 46 on the restorative scale: the surround is polished stone on every side, and the view is the pool and the travertine wall, no plant, no tree, no sky to speak of. The most evidenced move in the whole literature, greenery in the sightline, is structurally absent. The pavilion replaces it with water, and no model here has a term for water. That is in the limits.

GENERATED FROM raycast view fractions · skin-response integral per contact · Ulrich 1984, Dematté 2022 · dimension 07
441 · 54modelled negative affect, onyx hall · green room
6–96 scale
61 · 47

The gold room is the calm one. The green room is the tense one.

Both are lit by the same daylight. The onyx is warm under cool light, a true mismatch, which both colour studies found to be the comfortable corner. The Tinos marble is cool under cool light, a matched pairing, which they found raises tension. Same ceiling, same floor, same glass; the wall colour alone moves the reading by thirteen points, and against the intuition that the green room, facing the court and the sculpture, is the restful one.

This is a prediction, not a measurement. It is exactly the kind of prediction the pilot protocol exists to test, and finding 5 says where.

GENERATED FROM pigment × illuminant · affect model fitted to two studies · dimension 06
50signs in the building
3 right-angle turns in 51 m of route
by hand

Three readings from the plan, by hand, and a pilot site.

Wayfinding. There are no signs and there is no need for one. Every freestanding plane is placed so that the next destination is partly visible past its edge, the onyx shows the court opening, the glass shows the pool, which is Lynch's edge and landmark doing the entire job. The one decision the plan makes hard is the branch behind the onyx: from the door, the green room does not exist. Read from the plan; the dimension 08 tool is built around its own hospital plan and was not run here.

Circulation. Three right-angle turns between the steps and the court, none of them a corridor. The corridor study measured the pace drop at exactly this angle. A pavilion that makes you turn every fifteen metres is a pavilion that makes you walk slowly, which is what it was for.

The emotional map. Nobody has walked this building with sensors on, and the studio proposes to. It is open to the public, small enough for the dimension 01 protocol's eight zones, and the reading above makes two testable predictions: the sharpest settle at the door when the curtain is drawn, and the green room reading tenser than the gold one. The route and zones are the ones drawn here.

GENERATED FROM the plan, read with the methods of dimensions 08, 04 and 01 · not computed

WHAT I WOULD CHANGENothing that is not already in the building

It is a monument; the finishes are the point. The two reversible moves it already owns take the hall from 61 to 77 for a gallery weighting, and cost a curtain-pull and a carpet. Everything else the tool would suggest, timber, textile, planting, would be a different building.

ZoneMoveNowAfter
Onyx hallCurtain drawn, carpet laid, as 19296177
Green roomLeft as built · the carpet does not reach it5858
Glass passageCurtain drawn along its length6272
AnnexLeft as built5454

The passage figure is the hall's method on the passage's volume: 37 m² of velvet is most of its east wall too. The green room is behind the onyx and gets none of either, which is why the tense room stays the tense room.

THE LIMITSWhere this reading stops, and what comes next

  • Water. Two pools, one of them most of what the eye sees from the hall, and no model on this site has a term for the sight or sound of still water. The view reading of 34 is a floor, not a verdict.
  • Reflection. Polished marble, chrome and glass turn the hall into a hall of partial mirrors; the raycast census counts each surface once. The material reading is probably harsher than the room.
  • The zones. The building has no rooms; the rectangles are the tool's, and the ±1 m on each edge moves the sound readings by a tenth of a second and nothing else.
  • Whether the carpet is laid today, and how often the curtain is drawn. Recorded in 1929; to be checked on site, which is the next thing the studio does.

What it can show is the method holding on a building it was not designed for: every published fact used, every scaled one labelled, and one finding, the curtain, that the plans contain and the photographs hide.

05 · INDEPENDENT STUDYBiblioteca Sant Antoni – Joan Oliver

A library that is also a passage, from the street to a garden, with glass reading rooms bridged above it. Each room feels different depending on which glass wall you sit by.

RCR ArquitectesARANDA · PIGEM · VILALTA · 2002–2007
Comte Borrell 44 · 41.38°NEIXAMPLE, BARCELONA · OPEN DAILY
LibraryBUILDING TYPE · SETS THE WEIGHTS
BuiltFINISHES AND FURNITURE ONLY
4 zones · 2 routesONE THROUGH, ONE UP

Open the library in the reading tool →Loads the four zones as read here. Change the ceiling and see finding 2 settle. · See the building →

The garden walk along the glass, behind the slatted screenCredit: David Cardelús, via Arquitectura Catalana
Photograph: David Cardelús, via Arquitectura Catalana

What the numbers stand on

Less is published about this building than about the pavilion, and the reading says so. The finishes inside the boxes are the weakest input; finding 2 is built around that.

KNOWN · PUBLISHED

  • Library 1,723 m², senior centre 1,048 m², garden 1,400 m²; on the last free plot of the Eixample block
  • Two side volumes against the party walls; reading rooms in glass boxes bridged between them on the three upper floors, organised by subject and reading age; the top two linked by steps
  • Ground floor is a passage from the street to the garden, with the magazines; basement holds a small assembly hall and a gallery
  • Cortén and steel-slat enclosures; the boxes filter light between street and garden

SCALED · FROM PLANS AND PHOTOGRAPHS, ±1.5 M

  • Reading box about 14 × 8 m, 3.0 m clear
  • The door about 8 × 20 m, 5.5 m clear
  • Slats taken as halving the glass: 50% effective on both faces
  • Street face taken as south-west (even side of a NW–SE street), rounded to south; garden face to north

MAPPED · AND ONE THING UNKNOWN

  • Dark steel in the door → the tool's hardest surfaces; charcoal under 4000 K
  • Box interiors as photographed: white ceiling and walls, resin floor → vinyl; steel tables at the hand
  • Whether the box ceilings are absorbent is not in any source. Both states are read; a visit settles it
  • The tool has no open ends. The door's sound is corrected by hand in finding 4

Research card

Study 05 · Read

Problem
RCR's glass reading boxes bridge over a passage between the street and the garden, behind steel slats.
Question

In a reading box with the garden on one glass wall and the street on the other, which desk serves the reader?

Method and analysis
Method
One box read from a desk at each glass wall. The year's sun on both faces; the street canyon modelled for December. Six models, weighted for a library.
Analysis
Compared: Facing (garden north, street south-west), the slats, and a ceiling that is either hard or absorbent: both are read. Measured: Winter circadian dose against 0.30, view, hours of direct sun, reverberation.
Finding
Garden desk: view 80, winter dose 0.23. Street desk: view 34, dose 0.63. One box, two glass walls, and they do not agree.
Design implication
Put the long-stay desks on the street side in winter and the garden side in summer. The slats are what take the north desks under the line.

THE PLANA door on the ground, a bridge on each floor above

The building's argument is that every reading room has the street on one glass wall and the garden on the other. The two drawings test what that means for light: the year's sun on each face, and the winter sun at the street glass once the building across the street is in the way.

The year's sun around the reading box, true to north, from the same solar geometry the tool uses at 41.38°N. Amber is sun on the street glass (south-west), lilac is sun on the garden glass (north-east); the dashed lines are where one face hands the sun to the other. Computed: on 21 December the street glass has 7.8 hours of direct sun and the garden glass 1.2, all of it low, just after sunrise. In June the gap closes to 8.7 and 6.3. The slats are left out of the hours; they halve what each hour delivers. This is finding 1, drawn as a year.
Street to garden, scaled. The street is taken as the Eixample's 20 m and the building across it as 21 m; neither is in the sources, so both are labelled. Hour by hour on 21 December, a box's street glass counts as sunlit when the sun clears that building at desk height. Computed: box 3 gets 5.6 hours, box 2 4.5 and box 1 3.5, against 7.8 under open sky. The reading's 0.63 for the street desk assumes open sky, so on the lowest box it is an upper bound. The garden trees are drawn, not measured. Figures are the median adult, 1.685 m.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
The door (ground)Move through8 × 20 × 5.5open both ends · gardensteel · steel · stonesteelcharcoal · 4000 K
Reading box, garden sideFocus14 × 8 × 3.0north, 50% through slats · treesplaster · plaster · resinsteelwhite · 4000 K
Reading box, street sideFocus14 × 8 × 3.0south, 50% through slats · streetplaster · plaster · resinsteelwhite · 4000 K
Children's box (top)Create14 × 8 × 3.0north, 50% · trees, upper floorplaster · plaster · resinlaminatewhite · 4000 K

The garden-side and street-side readings are the same box, read from a desk at each glass wall, the tool reads one window at a time, so a room with two is read twice and said to be. Occupancy: six passing through, twenty-four in a box, twenty children.

THE READINGZone by zone, ceilings as photographed

Six models per zone, weighted for a library. Sound is read with the hard white ceiling the photographs show; finding 2 reads it again with an absorbent one.

WHAT THE READING FOUNDFive things about a building with two faces

10.23 · 0.63winter circadian dose, garden desk · street desk
threshold 0.30 · view 80 · 34
56 · 51

The garden desk has the view. The street desk has the winter.

One box, two glass walls, and they do not agree. Facing the garden, a reader has trees filling the sightline, the strongest restorative factor in the literature, and the view reads 80. Facing the street, the reading drops to 34. But the garden face looks north through steel slats, and from October to March the desk there gets 0.23 of a circadian dose against a threshold of 0.30. The street face, south-west through the same slats, gets 0.63. The room that restores the eye under-doses the body clock; the room that doses the clock has nothing to look at.

Without the slats the garden desk would read 0.32, just over the line. The screen that makes the façade is the thing that takes the north desks under it, if it wraps the garden face as the photographs suggest. That is a question for the visit, and the cheapest answer is to put the long-stay desks on the street side in winter and the garden side in summer.

GENERATED FROM solar geometry at 41.4°N for each face · circadian stimulus at the desk · view fraction × content · dimensions 03, 07
22.28sreverberation in a box with a hard ceiling
0.55 s with an absorbent one · target 0.4–0.6 s
0 or 100

One unpublished fact is worth forty-four points.

A 14 × 8 × 3 m box with glass on two long sides, plaster on the rest and a resin floor holds 2.3 s of reverberation with twenty-four people in it, a reading room where every chair scrape lasts. Swap the ceiling for an absorbent one and the same box reads 0.55 s, inside the band. Nothing else in the room changes; the sound reading goes from 0 to 100 and the box from 56 to 78.

The sources do not say which ceiling it has. A library completed in 2007 would normally have the absorbent one, and the photographs are ambiguous. So the reading declines to pick: the two states are both on this page, and the first thing the studio does on site is look up.

GENERATED FROM Sabine T60 on 336 m³ under both ceilings · dimension 02
Reading box, garden side, twenty-four readersT600 – 3 s · the black bracket is the focus bandZone
Hard white ceiling, as photographed2.2856
Absorbent ceiling, if it has one0.5578
Slatted timber ceiling · timber floor · oak tables0.5687
31.84box ceiling ÷ median body
abstract prime · adults 85 · children 100
85 · 100

The same box is the wrong height for the adults and the right height for the children.

Three metres over a 14 m wide floor is comfortable for every stature in the sweep, and it primes abstract thinking. For the children's floor, where the use is to make and imagine, the model calls that a good fit and scores 100. For the adult reading floors, where the use is to focus, it calls it a mismatch and takes fifteen points: focused work wants the lower, concrete sky. RCR built one section and stacked it three times, and the model can tell which floor the section was drawn for.

Nothing can be done about it in a built building, and nothing should be. It is worth knowing which floor to put the exam revision on.

GENERATED FROM population sweep over 64 statures · cathedral-effect prime by use · dimension 09
49.13 → 1.43sreverberation in the door
tool · corrected by hand for open ends
corrected by hand

The door is open at both ends, so the plan corrects the box reading.

Eight by twenty by five and a half metres of dark steel and stone: read as a closed room, Sabine gives nine seconds, a number no passage has ever had. The door is open at both ends to the street and the garden, and an opening is a perfect absorber, 88 m² of it. Put that in by hand and the passage reads 1.43 s, at the edge of the band for a space people move through and not far off what a covered street sounds like. The tool scores it 0 because it cannot see an opening; the honest figure is a pass.

This is the second thing a real building has taught the tool. The pavilion taught it about halls; this one teaches it that a room with no wall on one side is not a room, and the reading tool will grow an "open end" the next time it is revised.

GENERATED FROM Sabine T60 with the two open ends as unit absorbers · dimension 02 · not in the tool yet
52routes: through, and up
1 sign needed, at the stair
by hand

Three readings from the plan, by hand.

Wayfinding. From the pavement you see the garden through the building; the door is the sign, and Lynch would call the whole library a node. The decision the plan hides is the one that matters to a library user: where the stair is. It sits in a side volume, off the passage, and the passage gives no view of it, one sign at the passage's mid-point, at the height of a walking eye, is the only one the building needs. Read from the plan; the dimension 08 tool was not run here.

Circulation. Two rhythms in one building. The through-route is a straight 20 m, no turns, the pace of a street. The up-route is a stair in a box and then, between the last two floors, a run of steps inside the reading room itself, which the corridor study would predict slows people at exactly the point the library wants them slowed.

The emotional map. The garden is shared by the children's play area and the senior centre, and the reading rooms look down on both. The pilot protocol's route here would run street → door → garden → stair → box, and the prediction on record is the largest settle at the garden threshold, not in any reading room.

GENERATED FROM the plan, read with the methods of dimensions 08, 04 and 01 · not computed

WHAT I WOULD CHANGEFit-out only, and one move that costs nothing

A built library at refurbishment stage: finishes and furniture. The ceiling is the large move if it is needed; the tables are the small one; where the desks go is free.

ZoneMoveNowAfter
Reading box, garden sideSlatted timber ceiling · timber floor · oak tables5687
Reading box, street sideThe same · magazines and short stays here5183
Children's boxAbsorbent ceiling if absent · oak on the tables6387
The doorLeft as built, it is the building56*56*

* The door's figure carries the tool's sound score of 0; with the hand-corrected 1.43 s it would read in the seventies. It is shown as the tool gave it, because the correction is not in the tool yet. The garden-side figure of 87 assumes the hard ceiling was there to replace; if the box already has an absorbent one, the tables alone take it from 78 to 82.

THE LIMITSWhere this reading stops, and what comes next

  • The ceiling. The one fact the sound reading turns on is not published. Both states are given; one is true.
  • Orientation. South-west is a reading of the Eixample grid and the street numbering, not a survey. If the street face is west, the winter dose there falls from 0.63 to 0.46 and the finding softens but holds.
  • The slats. Taken as halving the glass on both faces. If the garden face is unslatted the north desk reads 0.32 and clears the threshold by a hair.
  • Open ends. The tool cannot read them; the door is corrected by hand and will be built into the tool next.

What it can show is a reading that names its own weakest input instead of hiding it, gives the answer under both states, and turns a visit into a two-minute check: look up, and look at the slats.

10 · INDEPENDENT STUDYKimbell Art Museum

Sixteen concrete vaults lit by hidden slits of sky. Its famous light is, by design, too dim for the body clock, and the building changes mood at dusk.

Louis Kahn1972 · WITH KOMENDANT (STRUCTURE) AND KELLY (LIGHT)
Fort Worth · 32.75°NTEXAS · OPEN TO THE PUBLIC, FREE
GalleryBUILDING TYPE · SETS THE WEIGHTS
BuiltA LISTED BUILDING · LAMPS AND RAILS ONLY
4 zones · 1 vaultTHE SAME SECTION SIXTEEN TIMES

Open the museum in the reading tool →Loads the four zones as read here. The tool has no skylight; finding 1 corrects it by hand. · See the building → · Wikipedia →

A gallery under the cycloid vault, daylight reflected down the concreteimages/research-kimbell-galleries.jpg · 1920 × 1080Credit: Andreas Praefcke, public domain
Photograph: Andreas Praefcke, public domain, via Wikimedia Commons

What the numbers stand on

The vault is published to the foot; the light is published as a quality, not a quantity, and that gap is what finding 1 is about.

KNOWN · PUBLISHED

  • 16 parallel post-tensioned concrete cycloid vaults, 5 in thick; 100 ft long, 20 ft wide, 20 ft high inside, 30.5 × 6.1 × 6.1 m, on 10 ft walls
  • Three wings: six vaults, four, six; three glass-walled courtyards; galleries on the upper floor
  • A slit along each crown; perforated anodised-aluminium reflectors that bounce sky onto the concrete and admit no direct sun
  • Travertine at the vault ends, white-oak gallery floors, lead roof; steel handrails blasted matte with pecan shells
  • Vaults run north–south; height capped at 40 ft to keep the Amon Carter's view

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The slit taken as 0.76 m wide: 23 m² of sky per vault
  • Gallery illuminance not published for the building; taken as the conservation range for paintings, 150–300 lux at the eye
  • Courtyard glazing taken as half an end wall; one courtyard planted
  • Occupancy: fifteen to a vault, ten passing the entrance, 120 in the auditorium

MAPPED · AND WHAT THE TOOL LACKS

  • Travertine → lime plaster (nearest absorption, warm surround) and beige for colour; concrete vault as itself; oak floor as itself
  • Daylight → 6500 K by day; the evening's lamps as 2700 K, which is what 1972 installed
  • Rooflights. The tool reads windows in walls; a slit in a vault with a reflector under it is beyond it. Light is corrected by hand
  • Paintings and partitions. Not in the tool, and they absorb. The sound readings are upper bounds

Research card

Study 10 · Read

Problem
Sixteen cycloid vaults, each lit through a slit and a perforated reflector that admits no direct sun.
Question

Is the most praised daylight in architecture enough light for the body?

Method and analysis
Method
One vault section drawn to scale; four zones. The rooflight the tool cannot see is corrected by hand. Six models, weighted for a gallery.
Analysis
Compared: Daylight by day against 2700 K lamps at dusk; a courtyard window or none. Measured: Circadian dose at 150 and 300 lux, colour and light affect, reverberation, ceiling-to-body ratio.
Finding
A dose of 0.15 to 0.26, under 0.30 by design. Negative affect 36 by daylight and 56 by lamplight, on the same travertine.
Design implication
In a gallery the visitor's dose is the wrong target, so the tool should say so rather than score it. Lamp colour changes the room's temperament at dusk.

THE VAULTOne section, sixteen times

The whole building is one drawing repeated: a 6.1 m span on 3.05 m walls, rising to 6.1 m at the crown, with the light coming in where the vault should be strongest and turned back onto it. The section is drawn below with the path the light takes; the plan is schematic, to show the rows, the courtyards and the one route the reading uses, in at the west, along a vault, past a courtyard.

One vault, cut across. Sky enters the slit, meets the perforated reflector, and reaches the room only off the concrete. The figure is the median adult, 1.685 m: the wall-top is 1.8 of them, the crown 3.6.
Schematic plan: north, centre and south rows of vaults running north–south, the three courtyards cut into them, the open porticos at the west. Courtyard positions approximate.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Gallery vault, interiorGather6.1 × 30.5 × 6.1rooflight only · no windowconcrete · travertine · white oaksteel railtravertine · daylight
Gallery vault at a courtyardGather6.1 × 30.5 × 6.1north end, 50% · courtyard treesconcrete · travertine · white oaksteel railtravertine · daylight
Entrance vaultMove through6.1 × 30.5 × 6.1west, 80% · portico and treesconcrete · travertine · travertinesteel railtravertine · daylight
AuditoriumGather6.1 × 30.5 × 6.1noneconcrete · travertine · carpetsteel railtravertine · 3000 K

The interior vault is read with no window, which is what the tool sees; its light is then corrected by hand. The vault's height is taken at the crown; its volume is a box, about 20% over the true cycloid.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a gallery. The interior vault's light reads 0 because the tool cannot see a rooflight; finding 1 gives the real figure, which is not much better, for a reason.

WHAT THE READING FOUNDFive things about the most praised light in architecture

10.15–0.26circadian dose in a gallery, by hand
threshold 0.30 · the tool reads 0
on purpose

The silver light is for the painting, not the body. Kahn knew.

Twenty-three square metres of sky per vault would light a room hard; the reflector takes almost all of it and gives back a glow off the concrete that sits, at the eye, in the range paintings can tolerate, 150 to 300 lux. On the circadian model that is a dose of 0.15 to 0.26, under the 0.30 a body needs, in a building people rightly call the best-lit room they have stood in. The two claims do not conflict. The light is beautiful because it is dim and even; it is dim and even because oil paint fades.

The tool scores the gallery 0 for light because it has no rooflight; corrected, it would score about 60. Both numbers would be wrong to act on. A gallery is the one room type where the visitor's dose is the wrong target, and the reading tool should say so rather than score it, which is a change to make.

GENERATED FROM circadian stimulus at 150 and 300 lux · conservation illuminance range for paintings · dimension 03 · not in the tool
236 · 56modelled negative affect, daylight · lamplight
6–96 scale · travertine walls
66 · 45

Calm by day, tense by lamplight. Same stone.

Travertine is warm. Under the sky's light, cool, silver, the thing everyone describes, warm stone under cool light is the true mismatch, which both colour studies found to be the comfortable corner: negative affect 36, colour reads 66. At dusk the reflectors go dark and the lamps come on, and in 1972 lamps were warm. Warm stone under warm light is the matched pairing that tests badly: 56, colour reads 45. The building most admired for its daylight has, on this model, a different temperament after it.

The lamp is the fix, as on every page here: cool white after dark keeps the mismatch and takes the evening room back to 56 on the colour reading. Whether the Kimbell has already made that move in a relamping is a thing to check; the model predicts the evening visitor would feel it.

GENERATED FROM pigment × illuminant · affect model fitted to two studies · dimension 06
33.99sreverberation in one vault, fifteen people
6.5 s for a six-vault suite · target 0.6–0.9 s
upper bound

A concrete vault on travertine and oak is a long room for sound.

Sabine on 1,135 m³ of concrete, travertine and oak gives four seconds; open six vaults into one suite and the volume grows faster than the absorption and it reads six and a half. That is the tool's reading and it is an upper bound: it counts no paintings, no partitions, no benches, and a gallery has all three. What it does say honestly is that the finishes do nothing for the ear, and that the hush people report in the Kimbell is people, art and manners, not the room.

Nothing here should change, the finishes are the building, and the tool's fit-out moves are all refused on a listed interior. The reading is recorded to be tested with a clap on site, which is a five-second experiment.

GENERATED FROM Sabine T60 on the stated finishes · dimension 02
41.81 · 3.62wall-top ÷ body · crown ÷ body
comfortable ratio 1.55
72

The vault is two ceilings, and the body reads the lower one.

The tool takes one height and reads the crown: 3.6 bodies, a hall, abstract prime, scored as generous. But the eye does not rest on the crown of a cycloid; it rests where the wall stops and the curve begins, at 3.05 m, 1.81 of the median body, just above the comfortable ratio and inside the range where a ceiling is still measured against oneself. Kahn put the human height at the springing and the sky above it. The reading tool has no term for a room with two heights, and this is the building that shows why it should: the 3 m line is the one the body uses, and the 6 m one is the one the light uses.

GENERATED FROM body-scaled ratio at the springing and the crown · dimension 09 · the two-height case is not in the tool
53landmarks in sixteen identical rooms
the courtyards
by hand

Three readings from the plan, by hand.

Wayfinding. Sixteen vaults of the same section, the same finish and the same light are, in Lynch's terms, a plan with no differentiation: every room is the room you just left. What saves it is the three courtyards, glass-walled, planted, the only places the sky comes in sideways, which are the building's landmarks and the reason a visitor can say where they are. The route the reading takes is along one vault and past one courtyard because that is the route the plan gives a memory to. Read from the plan; the dimension 08 tool was not run here.

Circulation. Vaults run north–south, so the building's pace is set by a 30 m straight with the light overhead and a turn at each end. Dimension 04 would predict an even walking rhythm, no corridor, no forced turn, and a slowing wherever a courtyard opens the wall.

The emotional map. The prediction on record: the settle points are the courtyard vaults, not the famous interior ones, view 80 against 18 is the largest gap in the whole reading, and the sharpest change in the building is at dusk, finding 2.

GENERATED FROM the plan, read with the methods of dimensions 08, 04 and 01 · not computed

WHAT I WOULD CHANGETwo things a listed building allows

Lamps and rails. Everything else the tool suggests, absorbent ceilings, textile, carpet, would harm the building here, and the reading refuses it. The two moves below are reversible and cost nothing the building would notice.

ZoneMoveNowAfter
Gallery vault, eveningCool white lamps after dark (5000 K)3841
Gallery vaultOak on the handrails4144
Courtyard vaultOak on the handrails5862
Entrance vaultOak on the handrails6164

Small numbers, on purpose. The building's readings are held down by two things the studio would not touch, the light level, which is for the art, and the finishes, which are the architecture, and the tool is being asked what is left. The evening figure is the gallery read under 2700 K lamps; 4000 K would give the same 41.

THE LIMITSWhere this reading stops, and what comes next

  • The light level. Taken from the conservation range, not measured in the building; the Kimbell may run brighter or dimmer, and finding 1 moves with it but does not cross the line either way.
  • What is in the rooms. Paintings, partitions and benches absorb sound and the tool counts none of them; the sound readings are ceilings, not measurements.
  • The evening lamps. 2700 K is what 1972 installed; whether a relamping has changed it is unpublished.
  • The vault as a box. Volume is 20% over the true cycloid; scale is read at the crown when the body reads the springing, finding 4.

What it can show is a building that fails two of the tool's tests deliberately and for good reasons, which is the most useful kind of result a reading can return: not a score, but which of its own targets do not apply.

11 · INDEPENDENT STUDYSeattle Central Library

Five stacked, shifted floors, and a well-known place to get lost: in 2019, 59 people were tracked through it. The plan shows why.

OMA · LMNKOOLHAAS, PRINCE-RAMUS · 2004 · $165.9 M
1000 Fourth Avenue · 47.6°NSEATTLE · 33,700 M² · 11 LEVELS · 60 M
LibraryBUILDING TYPE · SETS THE WEIGHTS
BuiltFINISHES AND FURNITURE ONLY
4 zones · 1 routeTHE ONE BUILDING HERE THE STUDIO HAS NOT STOOD IN

Open the library in the reading tool →Loads the four zones as read here. Two of them need a correction by hand, and finding 3 shows it. · See the building → · Wikipedia →

What the numbers stand on

The building is unusually well published and unusually well studied; the studio has read the plans and the wayfinding study, not walked the floor. That is said here and again at the end.

KNOWN · PUBLISHED

  • 11 levels, 60 m, 33,700 m²; glass-and-steel diagrid skin over five shifted platforms
  • Living Room on level 3; Red Floor (13 reds) on 4; Mixing Chamber on 5 with 338 computer stations; Books Spiral on 6–9 at a maximum slope of 2°; Reading Room on 10 with 400 seats
  • Kuliga et al. 2019, Environment and Behavior: 59 participants tracked on within-floor and between-floor tasks. Escalators "on different sides of the floor", "felt really random"; going up easy, going down unclear, no down escalator, stairs not always visible
  • Signage by Bruce Mau Design: floor-scale Futura ExtraBold, "make the building legible"

SCALED · FROM SECTIONS, ±15%

  • Living Room about 60 × 40 m, 12 m to the platform above
  • Mixing Chamber 60 × 40, 3.5 m; a Spiral level 60 × 40, 3.0 m
  • Reading Room about 40 × 30, 9 m under the sloping glass
  • Floor-to-floor on the Spiral taken as 3.7 m; the diagrid's mesh taken as halving the glass
  • Main glazing of each zone taken as east; the plan's rotation puts it nearer north-east

MAPPED · AND TWO THINGS THE TOOL LACKS

  • Carpet in the Living Room and Reading Room, rubber → vinyl on the Spiral; steel shelving and laminate at the hand; 4000 K throughout
  • Books. The tool has no shelving term, and a Spiral level is mostly book-face. Corrected by hand in finding 3
  • Plates. The tool's scale model reads a 40 m wide floor under 3 m as failing every stature, a visual-angle term at its threshold. Reported, not believed, in finding 4

Research card

Study 11 · Read

Problem
Five shifted platforms. Kuliga and colleagues tracked 59 people through it in 2019 and recorded confusion between floors.
Question

Can the plan and section explain why people get lost in this library?

Method and analysis
Method
The route from the Fifth Avenue door to a reading table, traced through the section with the escalators where participants reported them. Four zones; shelving added by hand.
Analysis
Compared: Line of sight to the next link at each arrival; how full the shelves are on a Spiral level. Measured: Arrivals with the next link out of sight, route length and climb, reverberation as the shelves fill.
Finding
Three arrivals on the way up with the next link out of sight, and no escalator down, as the 59 participants reported. A Spiral level stops ringing once it is about a third full of books.
Design implication
Legibility is a section problem before it is a signage problem. Books are an acoustic material, and the tool needs a term for shelving.

THE SECTIONFive platforms, four spaces between, one way up

OMA explained the building with one diagram: five solid platforms, each a programme that is stable, parking, staff, assembly, books, headquarters, shifted against each other, and the loose spaces the shifts leave between them for the programmes that change: the Living Room, the Mixing Chamber, the Reading Room. The section below keeps that idiom and adds the one thing the diagram never showed: how you get from one to the next. Escalators are on the sides the participants reported, alternating, and there is no escalator down. Dots mark each arrival where the next link is out of sight.

Section: the five platforms, the spaces between, and the route upimages/research-seattle-exterior.jpg · 1920 × 1080Drawn by the studio. Mark the three arrivals where the next link is out of sight, and that nothing goes down.
Photograph: Bobak Ha'Eri, CC BY 3.0, via Wikimedia Commons
Climb the route
The route up: escalator from the Living Room through Assembly to the Mixing Chamber, a second on the far side into the Books Spiral, 318 m of 2° ramp to level 9, a stair to the Reading Room. Down: not the same way. Move the walker with the slider or drag along the profile, which shares the section's height scale. The Spiral is unfolded into the plane of the section; in plan it winds round the floor. Of the 430 m from the Fifth Avenue door to a reading table, 74% is the Spiral, and it gains 11.1 m of the 34.8 m climbed: three quarters of the walk for a third of the height. Times assume 1.3 m/s walking, 0.7 m/s browsing on the ramp, 0.5 m/s standing on an escalator and on the stair. Platform positions scaled from published sections, ±15%. The figure is the median adult, 1.685 m.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Living Room (L3)Gather60 × 40 × 12east, 50% through mesh · cityplatform underside · glass, concrete · carpetsteelpale grey · 4000 K
Mixing Chamber (L5)Focus60 × 40 × 3.5west, 30% · cityexposed · concrete · carpetlaminatecharcoal · 4000 K
Books Spiral (one level of 6–9)Move through60 × 40 × 3.0east, 40% · cityexposed · shelving · rubbersteelpale grey · 4000 K
Reading Room (L10)Focus40 × 30 × 9east, 60% · sky through mesh, upper floorglass roof · concrete · carpetlaminatewhite · 4000 K

Occupancy for the acoustic reading: 120 in the Living Room, 200 at the computers, 60 browsing a Spiral level, 200 of the 400 seats taken.

Fill the shelves
One Spiral level as the tool reads it, 60 × 40 × 3 m, with the shelving it cannot see: 26 rows every 1.5 m, 2 m high, 6,240 m² of face. Empty, the level is the tool's own reading: 160 m² of absorption, 7.26 s. Each book face is taken at α 0.35. Computed: the level enters the 0.6 to 1.3 s band for a space people move through when the shelves are 34% full, and leaves it under 0.6 s past 81%. Full, it reads 0.49 s, which the tool's own band would score 92. A library needs to be about a third full before it stops sounding like a car park.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a library. Two of the twenty-four bars below are shown as the tool first produced them and corrected in findings 3 and 4; both stay visible, because that is what testing a tool on a real building is for.

WHAT THE READING FOUNDFive things about a building people get lost in

13arrivals on the way up with the next link out of sight
0 escalators down · 59 participants agree
by plan · confirmed

No number of signs fixes a destination you cannot see.

The dimension 08 tool's finding on its hospital plan was that a sign only works inside a line of sight, that two well-placed signs beat seven, and that past a point more signs make people worse. Seattle is the same finding at building scale. Each platform is shifted in plan, so the escalator that brought you to a floor and the one that takes you off it are on different sides, the participants' word was "random", and from three of the four arrivals on the route up, the next link is not inside any isovist. Bruce Mau's floor-scale lettering solves the within-floor task, and the study found within-floor tasks easy. Nothing on a wall solves between-floor, and the study found between-floor hard.

Then down. There is no down escalator. The stairs are, in the participants' words, not always visible, so the strategy that got a visitor up cannot be run in reverse; every descent is a new wayfinding task. This is the one reading on the page that was checked against people before the studio made it, and the people had already made it.

GENERATED FROM the section, read with the line-of-sight rule of dimension 08 · Kuliga et al. 2019 · not computed
2318mminimum ramp to climb the Spiral's four levels at 2°
4 min at walking pace · 8 min browsing
computed

The Spiral is a corridor a third of a kilometre long with no turns in it.

Three rises of 3.7 m at a maximum slope of 2° is at least 318 m of floor, more, wherever the slope eases, to get from level 6 to level 9 by the route the shelving takes. At 1.3 m/s that is four minutes; at the 0.7 m/s people browse at, nearly eight. Dimension 04's corridor study found pace drops at right-angle turns and recovers on straights; the Spiral has no right angles at all, which is why it reads as effortless to walk and why, per the study, going up felt easy. What it does not have is a short way. A reader who wants the 900s from the 100s walks the building.

The 2° also does a quieter thing: it takes the floor out of the body's reference. On a ramp that shallow the eye cannot see the slope and the legs can feel it, and the study's adjectives, overwhelming, stressful, sit alongside impressive and stimulating in exactly the proportion a sustained low-grade arousal would produce. That is a prediction for the pilot, not a finding.

GENERATED FROM rise ÷ tan 2° on the scaled floor-to-floor · pace values from dimension 04 · dimension 04, dimension 01
37.26 → 0.49sreverberation on a Spiral level
tool · corrected by hand for the books
corrected by hand

The books are the acoustic treatment, counted here by hand.

Read as a 60 × 40 × 3 m plate of exposed concrete, steel shelving and rubber floor, Sabine gives seven seconds, a car park. But a Spiral level is rows of open shelving every metre and a half, two metres high, both faces lined with paper, and a book face absorbs about a third of what reaches it. Twenty-six rows of 60 m shelving is 6,240 m² of book face, which is 2,300 m² of absorption in a room whose surfaces supply 160. Put the books in by hand and the level reads 0.49 s, just under the 0.6 to 1.3 s band for a space people move through, a score of 92 where the tool gave 0. The library is quiet because it is full of books; the tool did not know what a library was.

The pavilion taught the tool about halls, Sant Antoni about open ends, and this one about contents. Shelving goes into the reading tool next, as a wall type with an absorption and a surround value of its own.

GENERATED FROM Sabine T60 with shelf faces added as absorbers at 0.35 · dimension 02 · not in the tool yet
40 · 0scale, Mixing Chamber · Reading Room
3.5 m over 40 m · 9 m for focused work
reported, not believed

Over a forty-metre floor a low ceiling reads as oppressive, and the scale model's threshold needs a slope.

The Mixing Chamber and the Spiral score 0 for scale, and that is the visual-angle term: over a 40 m plate, a 3 m ceiling subtends under 6° at the far wall and the model calls it oppressive for every stature. The feeling is real, a low ceiling over a deep floor is the big-box feeling, but the model's threshold sits exactly on the value it produces, so 0 is a cliff, not a reading. It will be softened in the next revision and it is reported here as it fell.

The Reading Room's 0 is a different thing: an opinion. Nine metres of glass over a room for focused reading is 5.5 bodies of air, the cathedral prime, and the ceiling studies associate it with abstract rather than concentrated thought. The demonstration taught the tool to stop punishing halls for gathering; it still punishes them for focus, on purpose. Whether 400 readers under a glass sky concentrate less is a testable question and one of the better ones the pilot could ask.

GENERATED FROM the body-scaled model's visual-angle term · the cathedral-effect prime by use · dimension 09
50.30winter circadian dose in the Living Room, at the glass
Reading Room 0.37 · threshold 0.30
99 · 100

In a Seattle December the glass does its job, just, and only near it.

At 47.6°N under a diagrid mesh that halves the light, the Living Room reaches the threshold in the worst month and the Reading Room clears it. That is what a glass building is for and the model gives both rooms nearly full marks. The reading assumes a position near the glass; the plates are 40 m deep, and the model has already admitted, on the demonstration, that it reads deep plans too kindly. The Mixing Chamber, read from its west edge, holds 0.34; at a computer in the middle of 338 it will not.

The emotional map, by hand: the study's own adjectives. Impressive, creative, stimulating; inconsistent, overwhelming, frustrating, intimidating, stressful. Those are two ends of one arousal scale, and the prediction on record is that the Living Room and the top of the Spiral give the first set and the arrivals in finding 1 give the second.

GENERATED FROM solar geometry at 47.6°N · circadian stimulus at the desk · Kuliga et al. 2019 for the adjectives · dimensions 03, 01

WHAT I WOULD CHANGEWhat fit-out can reach, and what it cannot

The building's largest finding is not fixable: a shifted-platform section decides its wayfinding at concept stage, and no later stage can add a line of sight. That is the argument for reading at concept, made by a building that was not. What fit-out can reach is below.

ZoneMoveNowAfter
Living RoomAbsorbent platform underside · oak rails · planting4967
Reading Room2700 K lamps · oak tables · planting · absorbent soffits3959
Mixing Chamber2700 K · absorbent ceiling · oak desks · planting4465
Books SpiralLeft as built · the books already did it33*33*

* The Spiral's figure carries the tool's sound score of 0 and scale score of 0; with the books in by hand and the scale cliff softened it reads in the sixties. Shown as the tool gave it. The lamp move on both work floors is the same one as the demonstration's: white walls under 4000 K are a matched pairing; 2700 K turns it into the comfortable mismatch for the price of a bulb.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not stood in it. Every other building on this page can be walked to; this one was read from sections, photographs and a peer-reviewed study of other people walking it.
  • Zone dimensions are ±15%, worse than the others; the platforms are irregular and the sections published are at small scale.
  • Two of the tool's readings are wrong for reasons the page names, books, plates, and are shown wrong. The corrected numbers are by hand.
  • Orientation. The plan is rotated off the grid; east is a rounding. The light readings are at the threshold, so a rounding could move them either side of it.

What it can show is the one thing this page is for: the reading's biggest finding was made by fifty-nine people before the studio made it, from a section alone, which is the case for making it from the section before the building exists.

12 · INDEPENDENT STUDYTherme Vals

A building made of water, stone and warmth, read by tools that measure neither water nor warmth. It scores 44.3, which shows a reading is six questions, not a verdict.

Peter Zumthor1996 · VALS, GRAUBÜNDEN
Vals · 46.62°NSWITZERLAND · OPEN, TICKETED
HotelBUILDING TYPE · SETS THE WEIGHTS
Protected monumentLISTED WITHIN A FEW YEARS OF OPENING
4 zonesAND FOUR OF SIX MODELS OUT OF RANGE

Open the baths in the reading tool →Loads the four zones as read here. The tool believes the pools are empty and the room is at office temperature. · Wikipedia →

The baths from above: the outdoor pool, the stone terraces and the grass roof against the valleyimages/research-vals-terrace.jpg · 1920 × 1080Credit: Felipe Camus, CC BY 2.0
Photograph: Felipe Camus, CC BY 2.0, via Wikimedia Commons
Photography is not permitted inside the baths, so this reading is illustrated from outside and modelled from published sections and descriptions. That constraint is named again in the limits.

What the numbers stand on

The stone is published in millimetres and the water in degrees, and the tool has a model for one of those.

KNOWN · PUBLISHED

  • About 60,000 slabs of Valser quartzite from a quarry roughly a kilometre away, cut to three thicknesses, 31, 47 and 63 mm, laid as a composite of stone and concrete
  • Water temperatures as published: indoor pool 32°C, outdoor pool 36°C, fire bath 42°C, ice bath 14°C, flower bath about 30°C
  • The roof is a set of separate slabs with narrow slots of daylight between them; the building is cut into the hillside
  • A hollowed stone chamber people step into to sing, and a sequence of small baths reached from a dark passage

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The indoor bath hall taken as 30 × 40 × 5; the singing chamber as 3 × 3 × 5; the arrival passage as 2.5 × 40 × 2.6
  • The outdoor pool read as a 20 × 12 × 12 box, a deliberate stand-in that produces finding 3
  • Occupancy: forty in the bath hall, twenty-five outside, two in the chamber, two in the passage
  • Lamp temperature taken as 3000 K in the hall and 2700 K elsewhere, from published photographs

MAPPED · AND WHAT THE TOOL LACKS

  • Quartzite → concrete for absorption, stone underfoot and at the hand, grey for colour
  • Water. No term. Not as a surface, not as a sound, not as a thing the body is inside
  • Temperature. No term. A 42°C bath and a 14°C one are the same room to this tool
  • Steam, scent, and sound heard with the ears under the surface. Dimensions 05 and 02 have nothing to say about any of it

Research card

Study 12 · Read

Problem
Zumthor's baths: quartzite slabs, pools from 14 to 42°C, slots of daylight, and a stone chamber built to ring.
Question

What does a six-model reading say about a building made of water, stone and heat?

Method and analysis
Method
Four zones of the sequence, hall, Sound Stone, outdoor pool and arrival passage, read from published sections. Six models, weighted for a hotel. Nothing corrected by hand.
Analysis
Compared: The zones' use and dimensions. Measured: Scheme mean, reverberation in the Sound Stone, material, colour and view.
Finding
A scheme mean of 44.3. The Sound Stone rings for 2.95 s and scores 0 against a speech target. Water, temperature and sequence have no term at all.
Design implication
A reading is six questions, not a verdict. Water, temperature and sequence are the next terms, and a room for singing needs its own target.

THE ZONESFour rooms of a sequence, read as four rooms

Vals is a route before it is a set of rooms: you arrive through a dark passage, meet the large hall, and find the small baths off it. The tool reads rooms, one at a time, with no memory of the one before. Three of the four zones below only make sense in an order, and the reading has no term for order. That is finding 4.

Section A, hill to valley, to scale. The passage arrives in the dark; the hall is 30 m across under a 5 m roof of separate slabs with slots of daylight between them; the Sound Stone is a block with a chamber cut out of it; the outdoor pool sits beyond the glass. The water temperatures are the thing the tool cannot read. The figures are the median adult, 1.685 m.
Schematic plan, hill on the left and valley on the right, as in the section. Rooms and pools are drawn to the dimensions read; the positions of the blocks are approximate. The dashed line is where section A cuts.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Indoor bath hallRest30 × 40 × 5south, 35% · valleyconcrete · quartzite · quartzitestonegrey · 3000 K
Sound StoneRest3 × 3 × 5noneconcrete · quartzite · quartzitestonecharcoal · 2700 K
Outdoor poolRest20 × 12 × 12*south, 90% · valleyopen sky* · quartzite · quartzitestonegrey · 2700 K
Arrival passageMove through2.5 × 40 × 2.6noneconcrete · quartzite · quartzitestonecharcoal · 2700 K

* The outdoor pool has no ceiling and no fourth wall. The tool has no open rooms, a limit Sant Antoni's covered passage found first, so it is read as a tall box and the sound figure it returns is meaningless. Shown as run.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a hotel. Read the material, colour and view columns; the rest are reporting on a building that is not there.

WHAT THE READING FOUNDFive things about a building made of water, stone and heat

144.3scheme mean, four zones
6–96 scale
meaningless

A 44.3 for one of the most admired buildings shows why a reading is six questions, not a verdict.

Below the demonstration library. Below Seattle. Two points below the Barcelona Pavilion's worst zone. If the number were a verdict the studio would have to argue that Therme Vals is a mediocre building, and the studio will not, because the number is not a verdict. It is the answer to six questions, and the questions that make this building are not among them. There is no model for water, none for temperature, none for steam, none for scent, and none for the way sound arrives when your ears are under the surface.

Every reading on this site carries that caveat in small type. This one is the reason to print it large. A method that will not say where it stops is a method that will eventually be used to condemn something it never measured.

GENERATED FROM the four zone readings, weighted for a hotel · nothing corrected
22.95sreverberation in the Sound Stone
clarity 15 · target 0.4–0.7 s
scored 0

A stone room built to ring needs a target for singing, not speech.

There is a hollowed stone room at Vals that people step into and sing, because it rings. The sound model targets 0.4 to 0.7 seconds, which is the range for a room where you want to hear a person speak, and returns 0 for anything far above it. A room built to sustain a note is measured against a target for conversation and falls outside it.

The fix is a use, not a formula. The tool already knows the difference between rest, focus, gather, create and move through, and weights the six models accordingly. A sixth use, resonate, would invert the sound target instead of raising it, and would also cover a rehearsal room, a stairwell someone sings in and the Sagrada Família nave at the top of this page. That is the second time here that a missing use, rather than a missing model, produced a zero.

GENERATED FROM Sabine T60 and clarity index · dimension 02 · the resonate case is not in the tool
30scale reading, indoor bath hall
ratio 2.97 · 5 m over a 30 × 40 plate
found twice now

The same wide-floor threshold, seen a second time, sets the next fix for the scale model.

Five metres of height over a thirty-by-forty plate reads 0. Seattle's Mixing Chamber, 3.5 m over 40 m, also read 0, and the studio wrote it up there as the scale model's next fix: past roughly forty metres the visual-angle term sits on its threshold and the reading falls off a cliff rather than a slope. Two unrelated buildings, one a library and one a bath, hitting the identical edge is the point at which a limitation becomes a defect worth fixing rather than a caveat worth printing.

It matters here more than it did at Seattle, because at Vals the low ceiling over a wide floor is deliberate and is most of what the room feels like. The model is not merely blunt about it, it is pointed the wrong way.

GENERATED FROM body-scaled ratio, visual angle, shaft penalty · dimension 09 · the wide-plate case is a known defect
439arrival passage, total reading
light 0 · view 18
by design

The best-designed room in the sequence scores 39, because it is a preparation.

You reach the baths along a dark stone corridor with no daylight and nothing to look at. The tool scores it as a failed room: no light, no view, a long reverberation, a total of 39. It is not a failed room. It is the instrument that empties your eye before the hall, and the hall works because of it.

The reading has no term for sequence. Each zone is read alone, as though a visitor arrived in it from nowhere, and a room whose whole value is what it does to the next room is invisible to that. Dimensions 04 and 08 read a plan for rhythm and for wayfinding; neither reads a plan for preparation, and this corridor is the clearest case the studio has found for a model that would.

GENERATED FROM the zone read alone · dimension 04 not run · the sequence case is not in the tool
590view reading, outdoor pool
the highest on this page
the one that holds

One of the six models is standing on ground the building actually occupies.

The outdoor pool reads 90 on view, higher than anything at the Kimbell, Sant Antoni or Seattle. Ninety per cent of the field open, a planted edge, an Alpine valley beyond it. Ulrich's work is about exactly this, and nothing in the mapping had to be stretched to get there: the building really does hand a resting body a large, green, distant view, and the model really can read that.

Worth holding next to finding 1. The same instrument that produced a meaningless 44.3 across the scheme produced, in the same run, the single most trustworthy number in this section. That is what a partial instrument looks like from the inside, and it is why the readings are published model by model rather than as one score.

GENERATED FROM view fraction × content, planting · Ulrich 1984, Dematté 2022 · dimension 07

WHAT I WOULD CHANGENothing at all

The sweep proposes slatted ceilings, textile walls, timber linings and heavy planting, for a gain of nearly seventeen points across the scheme. In a protected monument made of one stone, every one of those is a refusal, and the refusals are not close. Printed in full, as always.

ZoneWhat the sweep proposesNowAfter
Indoor bath hallHeavy planting · slatted ceiling5268
Sound StoneHeavy planting · timber walls2848
Outdoor poolHeavy planting · textile walls5970
Arrival passageHeavy planting · tiled ceiling3959

Every row refused. Two of them, timber in the singing chamber and a tiled ceiling in the dark corridor, would destroy the exact effect the room exists to produce, which means the sweep is not merely over-eager here, it is inverted. A sweep that can propose the opposite of the brief needs a term for what the room is for beyond its five uses. That is the same specification finding 2 asked for, arriving from the other direction.

THE LIMITSWhere this reading stops, and what comes next

  • Water, temperature, steam, scent and underwater sound are the building, and they are the next dimensions the studio's models need. This study maps exactly what they would have to read.
  • The studio has not stood in it, and photography is not permitted inside, so the interior mapping rests on published sections and descriptions rather than on a visit or a photograph.
  • Zone dimensions are ±20%, the loosest on this page. The bath hall in particular is an irregular set of stone blocks read as one rectangle.
  • The outdoor pool is not a room and is read as one, so its sound figure should be ignored rather than interpreted.

What it can show is where the instrument ends. Every other reading on this page found something about a building; this one found something about the tool, four times over, and each of the four came back with a specification attached. A method that only ever gets pointed at buildings it can already read never finds out what it is missing.

02 · INDEPENDENT STUDYBruder Klaus Field Chapel

Nine square metres of burnt timber in a wheat field, twelve metres tall, lit by one hole in the roof. The best material reading on this page, and the worst for scale.

Peter Zumthor2007 · BUILT BY THE FAMILY WHO COMMISSIONED IT
Mechernich-Wachendorf · 50.55°NGERMANY · OPEN, FREE
WorshipBUILDING TYPE · SETS THE WEIGHTS
BuiltNO HEATING, NO INSTALLED LIGHT
2 zonesTHE BUILDING ONLY HAS TWO

Open the chapel in the reading tool →Two zones, not four. The tool reads the oculus as no window at all. · Wikipedia →

The oculus from inside: the charred flutes of 112 trunks converging on the only lightimages/research-bruder-klaus-light.jpg · 1920 × 1080Credit: Axel Kirch, CC BY-SA 4.0
Photograph: Axel Kirch, CC BY-SA 4.0, via Wikimedia Commons
The whole light of the building, and the whole of what the tool cannot see. The opening is unglazed, so rain and snow land on the floor.

What the numbers stand on

The construction is published in unusual detail because it was a hand build, and the dimensions are not, because it was a hand build.

KNOWN · PUBLISHED

  • 112 spruce trunks set as a tent-shaped formwork; 24 layers of rammed concrete, roughly half a metre each, poured one layer a day
  • The timber was then burned out over about three weeks of smouldering fire, leaving the interior charred and fluted
  • Floor of hand-poured lead and tin; about 350 blown-glass spheres set in the holes the formwork ties left
  • A teardrop opening left open to the sky; a triangular steel door; no heating and no electric light

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The chamber taken as 3 × 3.5 × 12, about nine square metres, scaled from photographs against a standing figure
  • The entry wedge taken as 1.2 × 4 × 12
  • Occupancy: three in the chamber, one in the wedge, which is what the room holds
  • Lamp temperature 2700 K, standing for candles, since there is no installed light

MAPPED · AND WHAT THE TOOL LACKS

  • Charred fluted spruce → timber walls, which is the one mapping on this page that needed no compromise at all
  • Lead-tin floor → stone; at the hand, stone in the chamber and steel at the door
  • The oculus. A hole in a roof reads as no window, the same gap as the Sagrada Família, Kimbell and Seattle readings. Finding 3
  • Weather. The room is open to the sky and has no heating, and there is no thermal model and no rain

Research card

Study 02 · Read

Problem
112 spruce trunks burned out of rammed concrete, a hand-poured lead and tin floor, and an unglazed oculus 12 m up.
Question

How do nine square metres of burnt timber and one hole in the sky read?

Method and analysis
Method
Two zones, the chamber and the entry wedge. Noon sun traced through the oculus on three dates; a raycast census of the visual field. Six models, weighted for worship.
Analysis
Compared: Sun angle by season; the share of the visual field within reach. Measured: Material reading, touch share, surround restorativeness, height-to-body ratio, how low direct sun reaches.
Finding
Material 84, the highest of the sixteen; scale 0, at 7.12 bodies of height. Direct sun never comes lower than 9.2 m.
Design implication
Material presence can be computed, not only argued. The tool needs a rooflight term and a scale target for sacred height.

THE ZONESTwo rooms, and one of them is a gap

Every other building on this page was read as four zones because four is what it takes to describe a plan. This one has a chamber and the wedge you come in through, and inventing two more to fill the format would be dishonest. It is read as two, and the index says so.

The chamber cut in the plane of the noon sun, scaled: about 3.2 m across at the floor, the oculus about 1.2 m across at 12 m, the charred walls leaning straight between. A beam through the oculus lands on the far wall, and its lowest point is where the ray from the near edge meets it. Computed at 50.59°N: at noon on 21 June the sun comes down to 9.2 m, on 20 March to 11.0 m, on 21 December to 11.6 m. Direct sun never reaches the lower three quarters of the room. Rain falls straight and lands on the lead-tin floor, which sees about 0.25% of the sky. The figure is the median adult, 1.685 m.
Above, the chamber in plan with the June sun patch hour by hour: it sits on the wall opposite the sun and travels round the room through the day; the larger and brighter the dot, the lower it reaches. Below, the lowest point of the patch through the day on three dates, from the same geometry as the section. It never enters the band a standing body occupies. The five-sided outline and the teardrop are approximate, and so is north.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
The chamberRest3 × 3.5 × 12none*open sky* · charred timber · lead-tinstonecharcoal · 2700 K
The entry wedgeMove through1.2 × 4 × 12noneopen sky* · charred timber · lead-tinsteel doorcharcoal · 2700 K

* The oculus is the only opening and the tool cannot read it, so glazing is entered as none and the light readings come back 0. Corrected by hand, the chamber's daylight is a narrow, moving, very high-contrast patch, which is a condition the circadian model was not built for either.

THE READINGTwo zones, as the tool gives it

Six models per zone, weighted for worship. Two of the twelve readings are the best of their kind on this page and two are the worst, which for a nine-square-metre room is a result in itself.

WHAT THE READING FOUNDFour things about nine square metres

184material reading, the chamber
touch share 62% · surround 0.82
highest on this page

The best material reading in the set, and the room is smaller than a parking space.

The raycast census sends sixty by thirty-six rays from a standing eye and asks what fills the visual field; the skin-response integral asks what the hand actually meets. In a room three metres across, 62% of the field is within reach and all of it is burnt timber, hand-poured metal or stone. Surround restorativeness comes back 0.82, which is the figure the model gives a room made entirely of natural material with nothing synthetic in it at all.

Zumthor has argued in prose for thirty years that material presence is the substance of architecture. This is that argument arriving from a ray census and an ordinal scale fitted to somebody else's experiment, which is the only kind of agreement worth having.

GENERATED FROM raycast visual-field census, 60 × 36 rays · skin-response integral per contact · surround restorativeness · dimension 07
27.12height ÷ body, both zones
comfortable ratio 1.55
scale 0

Seven bodies of air standing on end over a three-metre room.

Twelve metres of height in a plan you can cross in four steps. It is the most extreme aspect ratio in the set by a wide margin, and the scale model scores it 0 through the shaft penalty, a term written to catch rooms that are tall because a service riser or a light well made them tall. This one is tall on purpose and the penalty cannot tell the difference.

That is the same shape of problem as the cathedral prime in the Sagrada Família reading at the top of this page, at the other end of the range. The scale model has a ceiling above which it stops distinguishing and a floor below which it stops forgiving, and Sagrada Família and Bruder Klaus sit one on each. Both are deliberate, both are read as faults. A term for whether the height is doing something, rather than only how much of it there is, is what both findings are asking for.

GENERATED FROM body-scaled ratio over 64 adult statures · shaft penalty · dimension 09
34 of 8of the studio's first eight buildings
lit by something the tool cannot see
the next model

Four of the first eight buildings are lit from above, which makes the rooflight the light model's next term.

The Sagrada Família's lit vault crowns. The Kimbell's slit vaults. Seattle's roof glazing. This chapel's oculus, which is the only opening it has. Each was written up in its own section as a limitation of the tool, and each time the studio corrected the number by hand and moved on. Four in eight is the point at which that stops being reasonable.

The light model reads windows in walls because solar geometry against a vertical plane is the tractable case and it is what the field data was collected on. A rooflight needs a different integral and an honest treatment of the reflector or the vault under it. It is the largest single piece of work the reading tool is missing, and it took reading eight buildings nobody commissioned to establish that, which is the argument for reading them.

GENERATED FROM the studio's first eight readings · dimension 03 · the rooflight case is not in the tool
41.17sreverberation in the chamber
clarity 37 · scored 72
best sound on the page

The best sound reading on this page, and the reason behind it is worth writing down.

A twelve-metre shaft of hard material ought to ring. It does not, and the tool knows it does not: 1.17 seconds, clarity 37, a score of 72, the best sound reading on this page. The reason is that the mapping entered timber walls, and the walls are timber, charred, fluted by 112 trunks into a surface with far more area than its footprint suggests.

The accident is that the tool is reading a flat timber wall and getting the right answer for a corrugated burnt one. It would be wrong about why. That is worth writing down rather than claiming as a success, because the next building with a deeply modelled hard surface will get the same treatment and the accident will not repeat.

GENERATED FROM Sabine T60 on the stated finishes · clarity calibrated to the Fraunhofer benchmark · dimension 02

WHAT I WOULD CHANGENothing, in a building with nothing in it

The sweep offers seven points for heavy planting, a tiled ceiling and wool at the hand. There is no ceiling to tile, the room is open to the weather, and the whole argument of the building is that there is nothing in it. Refused.

ZoneWhat the sweep proposesNowAfter
The chamberHeavy planting · tiled ceiling3642
The entry wedgeHeavy planting · wool at the hand5562

The wedge's row is the more interesting refusal. Wool on a handle is the cheapest move the tool knows and it is right about it nearly everywhere else on this site. Here the thing your hand meets is a cold steel plate you have to lean on to open, and that weight is the first thing the building does to you. A move that is correct in most of the buildings on this page is still a move that has to be argued each time.

THE LIMITSWhere this reading stops, and what comes next

  • The dimensions. Scaled from photographs against a standing figure, not from a drawing. Call them ±20%, and the scale finding survives any of it.
  • The light. The oculus is the building's only light and is unreadable, so the 0 in both zones is a blank rather than a result.
  • The weather. No heating, no glazing, rain on the floor. There is no thermal model and no wet model, and in this chapel both would matter.
  • The smell. Burnt wood, for years, is the first thing everyone who has been reports, and dimension 05 was never built into the reading tool.

What it can show is that a nine-square-metre room can produce the best and the worst reading among the studio's first eight buildings at the same time, on two different models, and that neither number is a judgement of the chapel. One is the tool agreeing with the architect and one is the tool meeting the edge of its own range.

13 · INDEPENDENT STUDYJewish Museum Berlin

The Holocaust Tower scores 21, the lowest on this site, and every number is correct. Acting on it would be a serious mistake.

Daniel LibeskindCOMPETITION 1989 · BUILT 1999 · OPENED 2001
Berlin · 52.52°NGERMANY · OPEN TO THE PUBLIC
GalleryBUILDING TYPE · SETS THE WEIGHTS
BuiltREAD AS BUILT · NOTHING PROPOSED
4 zonesTHREE OF THEM MEANT TO BE ENDURED

Open the museum in the reading tool →Loads the four zones as read here. Read finding 1 before you read the scores. · See the building → · Wikipedia →

The zinc skin of the Libeskind building, cut by its slashed windowsimages/research-jmb-zinc.jpg · 1920 × 1080Credit: Ansgar Wernst, CC BY-SA 4.0
Photograph: Ansgar Wernst, CC BY-SA 4.0, via Wikimedia Commons
The zinc skin outside. Inside, the floor of the Memory Void holds Menashe Kadishman's Shalekhet, which both absorbs and rings underfoot; the reading counts it as neither, which is named in the limits.

What the numbers stand on

The building is described in the literature far more often than it is dimensioned, so the zones here lean harder on photographs than anywhere else on this page except the chapel.

KNOWN · PUBLISHED

  • About 15,500 m², zinc-clad, a zigzag plan; no entrance of its own, so you enter through the Baroque Kollegienhaus next door and descend
  • Three underground axes, named Continuity, Exile and Holocaust, and voids cut vertically through the building
  • The Holocaust Tower: a bare, unheated concrete shaft with one slit near the top and a heavy door
  • The Garden of Exile: 49 concrete pillars on ground sloping about 12 degrees, planted with oleaster on top
  • The windows are slashes cut across the facade rather than openings placed in it

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • Holocaust Tower taken as 4 × 4 × 24; Memory Void as 4 × 17 × 20; Garden of Exile as 15 × 15 × 6; exhibition floor as 20 × 40 × 4
  • Glazed fraction on the exhibition floor taken as 0.12, from elevations, which is what a facade of slashes comes to
  • Occupancy: six in the Tower, ten in the Void, twenty in the Garden, eighty on the exhibition floor
  • The Tower has no installed light at all; 2700 K is entered as a placeholder and carries nothing

MAPPED · AND WHAT THE TOOL LACKS

  • Fair-faced concrete as itself on ceiling, wall and floor; the door as steel at the hand
  • The sloping floor. The Garden's ground tilts about 12 degrees and there is no term for a floor that is not level. Finding 4
  • Temperature. The Tower is unheated and that is its main instrument, and there is no thermal model
  • The iron faces. Ten thousand cut plates on the Void's floor absorb and ring at once, and are counted as neither

Research card

Study 13 · Read

Problem
Libeskind's Holocaust Tower: an unheated concrete shaft, 24 m tall, with one slit of light near the top.
Question

What does a very low reading mean for a room designed to be hard to be in?

Method and analysis
Method
Four zones: three meant to be endured and an ordinary exhibition floor as the control. Sky in sight computed across the Garden of Exile; the scale model swept from 3 to 30 m.
Analysis
Compared: The use given to each room, to rest in or move through; position in the garden. Measured: Total reading, reverberation, height-to-body ratio, share of sky in sight.
Finding
The Tower reads 21, the lowest on this site: light 0, sound 0, scale 0, and every figure correct. In the Garden of Exile, 18% of the sky is in sight at the centre and 77% at the corners.
Design implication
A reading says what a room does, not whether it is right. The brief decides what a low number means.

THE ZONESThree rooms to be endured, and one ordinary one

The four zones were chosen to put the building's extremes next to its ordinary floor, because the argument of this section is about what a low number means and you cannot make it without something normal in the frame. The exhibition floor is the control.

The Tower and the Void at one scale, and the tool's own scale model, copied from the reading tool, run on a bare concrete shaft 4 m wide at every height from 3 to 30 m. Height is shared: each room's top meets its curve. Read as a room to rest in, the shaft falls to 0 by 5 m; read as a room to move through, it holds at 72 from 5 m up. Computed: the Tower read as a room to move through scores 72, and the Void read as a room to rest in scores 0. The seventy-two points in finding 3 come from the use each room was given, not from its shape. Figures are the median adult, 1.685 m.
Left, the 49 pillars in plan, scaled: 1.1 m square at a 2.15 m pitch, 6 m tall. At every crossing of the alleys, rays are cast from eye height over the whole sky and stopped by the pillars, which lean with the ground. Computed: in the middle of the garden a visitor sees 18% of the sky, at the corners 77%, on open ground on the same slope 91%. Right, the section up the slope: the pillars stand square to the ground and the bodies stand plumb, so every pillar edge is 12° off the vertical the body is holding. The oleaster on top is left out, so the sky figures are upper bounds.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Holocaust TowerRest4 × 4 × 24noneconcrete · concrete · concretesteel doorgrey · none
Memory VoidMove through4 × 17 × 20noneconcrete · concrete · concretesteelgrey · 3000 K
Garden of ExileMove through15 × 15 × 6*south, 90% · skyopen sky* · concrete · cobblesstonegrey · 2700 K
Permanent exhibitionGather20 × 40 × 4west, 12% · cityplaster · plaster · timberlaminatewhite · 3000 K

* The Garden is outdoors and is read as a box, the same wrong reading the Vals pool gets in its own reading, so its sound figure should be ignored. Its floor also slopes, and nothing in the tool knows that.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a gallery. Every number below is correct. Finding 1 is about what follows from that, which is not what it looks like.

WHAT THE READING FOUNDFive things about a building designed to score badly

121Holocaust Tower, total reading
light 0 · sound 0 · scale 0
and correct

The lowest reading on this site, produced by the most effective room in the building.

No daylight the model can use, 5.61 seconds of reverberation in a concrete shaft, a height-to-body ratio of 14.24, a material reading of 36 and nothing to look at. Five of the six readings are as bad as the models go, and every one of them is accurate. People stand in that room for a few minutes and come out changed, which is the entire brief, and the brief was to make a room that is hard to be in.

An instrument that returned 21 and stopped there would recommend demolishing the best thing Libeskind has built. The studio's rule, written on the purpose page and tested here: the reading says what the perceptual conditions are, not whether the architecture is good. Conditions and intentions are different measurements. This building separates them further than any other on this page, which is exactly why it is on it.

GENERATED FROM the zone as run, gallery weights · nothing corrected
236material reading, Tower and Void
touch share 63% · surround 0.32
working exactly

The material model is doing its job and reaching the architect's intention.

Concrete overhead, concrete on every wall, concrete underfoot, a steel door, and 63% of the visual field within reach. Surround restorativeness comes back 0.32, against 0.82 for the burnt-timber Bruder Klaus chapel. Same census, same integral, same scale, opposite ends of it.

This is the reading to point at when someone asks whether the models actually measure anything. Two small rooms, both hard, both dim, both made of one material, and the model separates them by half its range on the basis of which material. It is not detecting size or light or budget. It is detecting what the surfaces are, which is what it claims to do.

GENERATED FROM raycast census · skin-response integral · surround restorativeness · dimension 07
30 · 72scale reading, Tower · Void
ratio 14.24 · 11.87
a step, not a slope

Two concrete shafts, seventy-two points apart, show where the cathedral prime needs a slope instead of a step.

The Tower is 4 m square and scores 0. The Void is 4 m wide and 17 m long, which puts it the other side of the cathedral prime, and it scores 72. Both are bare concrete shafts around twenty metres tall that you enter through a heavy door and want to leave. The model puts seventy-two points between them.

The prime is a step function, and a step in the middle of a continuous quantity will always produce a pair like this eventually. Finding it required two nearly identical rooms in one building, which is not a condition you can arrange on purpose. Recorded as a defect in the scale model, alongside the wide-plate cliff that Vals and Seattle found twice.

GENERATED FROM body-scaled ratio · cathedral-effect prime · dimension 09 · the step is a defect
461Garden of Exile, total reading
the best zone in the museum
and it tilts

The one room that reads well is the one built to make you unsteady.

Forty-nine pillars on ground sloping about twelve degrees, planted above head height, open to the sky. The tool sees a December dose of 0.57, a view reading of 59 and a total of 61, the highest in the building, and it is not wrong about any of that. What it cannot see is the floor, which is the whole device: visitors report disorientation, and the ground is the reason.

There is no term anywhere in the six models for a floor that is not level, because every room the tool has been pointed at had a flat one. A slope term would also read a ramped foyer, a raked auditorium, a sloping street entrance and half the ground floors in Barcelona. This garden is where to write it.

GENERATED FROM view fraction × content, planting, solar geometry · dimensions 07 and 03 · the slope case is not in the tool
50.19December dose, permanent exhibition
threshold 0.30 · light 71
the ordinary problem

The one ordinary room in the museum has the one ordinary problem.

A facade of slashes comes to about 12% glazing, and the December dose lands at 0.19. That is not a dramatic number and it is not meant to be: it is close to the winter shortfall measured at real desks in real offices, which is the field data the light model is calibrated against. The room works in summer and runs on electric light from November to February.

It was the last of the studio's first eight readings, and the right one to end that set on. Seven extraordinary rooms produced seven findings about the limits of the instrument. This one, an ordinary gallery floor with small windows in a northern city, produced the finding the instrument was built for, on the first attempt, with nothing corrected by hand. That is what the tool is for. The other seven are how you find out what it still needs.

GENERATED FROM solar geometry for 52.52°N · circadian stimulus 09:00 to 17:00 · dimension 03

WHAT I WOULD CHANGEOne floor, and nothing else

The sweep offers twenty points across the scheme for textile walls, wool at the hand and heavy planting. In the Tower and the Void those moves would delete the building. On the exhibition floor, which is an exhibition floor, most of them are ordinary and some are overdue.

ZoneMoveNowAfter
Permanent exhibitionAbsorbent ceiling · planting at the rest points5575
Garden of ExileLeft as built · the planting is the artwork6161
Memory VoidRefused · textile and wool in the Void3838
Holocaust TowerRefused · every move deletes the room2121

The exhibition floor's twenty points are real and cheap: 3.6 seconds of reverberation on a gallery floor at eighty people is a room where nobody can hear a guide, and an absorbent ceiling is the least invasive fix in the whole toolkit. The three refusals above it are not close calls, and the studio would put them in writing before starting, because a sweep left running unsupervised would have proposed all four.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has stood in it, but did not measure it. Zone dimensions are scaled from photographs and published description, ±20%.
  • The Tower's temperature. It is unheated, in Berlin, and that is the largest single thing the room does. There is no thermal model.
  • The Void's floor. Ten thousand iron plates absorb sound and ring underfoot at the same time, and the tool counts them as neither, so 9.12 s is an upper bound and the noise a visitor makes walking is missing entirely.
  • The Garden's slope, finding 4, and the fact that it is outdoors and read as a box.

What it can show is the difference between a measurement and a judgement, held apart under the hardest possible conditions. Every number in this section is right. Acting on any of the first three zones would be indefensible. Both of those sentences have to be true at once for the method to be worth anything, and this is the building that makes you say so.

03 · INDEPENDENT STUDYJewel Changi Airport

A forest of three thousand trees under a glass dome. The best view on this page, and an echo that the trees and a 40 m waterfall change completely.

Safdie Architects2019 · WITH RSP, PWP LANDSCAPE, BUROHAPPOLD
Changi, Singapore · 1.36°NIN FRONT OF TERMINAL 1 · PUBLIC AREAS FREE
TransportBUILDING TYPE · THE NEAREST THE TOOL HAS
BuiltABOUT 300,000 VISITORS A DAY
4 zonesTHE DOME, A TRAIL, A RING, A BASEMENT

Open Jewel in the reading tool →Loads the four zones as read here. The dome's sound reading is a sealed box; finding 1 is why. · See the building → · Wikipedia →

The Rain Vortex falling from the oculus into the Forest Valleyimages/research-jewel-forest-valley.jpg · 1920 × 1080Credit: Mike Peel, CC BY-SA 4.0
Photograph: Mike Peel, CC BY-SA 4.0, via Wikimedia Commons
The picture every visitor takes. The water, the trees and the glass are the three things this reading is about, and the tool can see only one of them properly.

What the numbers stand on

The big figures are published and round. The rooms inside them are not published at all, so every zone below is scaled.

KNOWN · PUBLISHED

  • Opened 2019; about 135,700 m² of floor over basement and five storeys above ground
  • A steel and glass gridshell about 200 m long and 150 m wide, with more than 9,000 glass panels
  • The Rain Vortex falls 40 m from an oculus in the roof; the Shiseido Forest Valley covers about 22,000 m² over five storeys, with around 3,000 trees and 60,000 shrubs
  • The Canopy Park on the top level, about 14,000 m²; the engineers describe tuning the acoustics so the waterfall calms rather than overwhelms

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The whole dome read as one room, 150 × 200 × 40 m, because sound fills all of it; the Vortex floor is that room at ground level
  • A Forest Valley trail read as 60 × 6 m under 30 m of dome; the retail ring as 80 × 10 × 5 m, looking into the forest
  • A basement retail floor as 60 × 40 × 4.5 m, with no window
  • Occupancy: 3,000 under the dome at a busy moment, 80 on the trail, 200 on the ring, 400 below ground; the published figure is a daily average, not a moment

MAPPED · AND WHAT THE TOOL LACKS

  • Glass roof and walls → concrete for absorption, the nearest hard surface; stone floors; steel at the hand, for the balustrades
  • The forest as an absorber. Planting changes the view reading and nothing else. Finding 1
  • The glass roof. A rooflight reads as no window, so the dome's light is entered through its side as a stand-in. Finding 2
  • The waterfall. The tool reads how long a sound lasts, not what is making it. There is no term for a 40 m fall of water

Research card

Study 03 · Read

Problem
Three thousand trees, a 40 m waterfall and more than 9,000 glass panels, in front of an airport terminal.
Question

What happens to sound in a forest under a glass dome?

Method and analysis
Method
The dome read as one room, then as a forest trail, a retail ring and a basement. The forest counted by hand as an absorber.
Analysis
Compared: Absorption of the planting, from 30% to 70%; the volume of the dome. Measured: Reverberation, view, circadian dose.
Finding
61 s as a sealed box; 8 to 20 s with the forest counted. The highest view reading of the sixteen.
Design implication
Planting is an acoustic material, and a steady sound of water changes what reverberation means. The tool needs sound sources.

THE ZONESOne dome, read four ways

Everything under the glass shares one volume of air, so the dome is read once as a whole room and then again as a trail through the forest. The shops that ring its edge are a different kind of room: lower, air-conditioned, looking in. Below them are floors that see neither sky nor forest. The section is schematic; the width, the fall of the Vortex and the figure are to scale.

Schematic section across the 150 m width. The roof dips to the oculus and the Rain Vortex falls 40 m through it. The forest steps down in terraces towards the water; the shops sit under the edge of the dome; the basement sits under all of it. The median adult, 1.685 m, is drawn to the same scale, beside the fall.
Schematic plan. The oval is drawn to the published length and width; everything inside it is arranged, not surveyed. Dashed outlines are the zones as read; the basement floor sits beneath the whole plan.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
The Rain Vortex floorGather150 × 200 × 40south, 90%* · treesglass* · glass* · stonesteel railsage · 6500 K
Forest Valley trailMove through60 × 6 × 30south, 90%* · treesglass* · glass* · stonesteel railsage · 6500 K
Retail ringMove through80 × 10 × 5north, 40% · treesplaster · plaster · stonesteel railwhite · 4000 K
Basement retail floorMove through60 × 40 × 4.5noneplaster · plaster · stonesteel railwhite · 4000 K

* The dome is all glass and mostly roof. The tool reads glass in walls only, so the dome's light is entered as a 90% glazed south wall, and its glass surfaces are entered as concrete, the nearest hard surface the sound model has. At 1.36°N the choice of cardinal barely matters.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for transport, the nearest type the tool has to an airport's front garden. Every zone scores 0 on sound, and the reason is different in the dome and in the basement.

WHAT THE READING FOUNDFour things about a forest under glass

161 → 8–20sreverberation under the dome
tool · with the forest counted by hand
corrected by hand

The largest absorber in the building is the forest, counted here by hand.

Read as a sealed box of hard surfaces, 1.2 million cubic metres of air under glass rings for 61 seconds. No room does that, and this one does not either. The sound model knows planting only as something to look at. Counted by hand as what it also is, about 22,000 m² of leaves and soil absorbing somewhere between 30% and 70% of the sound that reaches it, the figure falls to between 8 and 20 seconds, depending on the absorption and on how much smaller the real dome is than a box.

That is still long, and it is still the wrong question. Under this dome there is always a sound, 40 metres of falling water, and a steady sound like that covers the voices and footsteps a long decay would otherwise smear. The engineers say they tuned the acoustics so the water calms. The tool measures how long a sound lasts and has no term for what is making it. Sant Antoni's open ends, Seattle's shelving, and now a forest: the third time a real building has shown the sound model an absorber it cannot count.

GENERATED FROM Sabine T60 on the stated volume and finishes · the forest added by hand at 0.3 to 0.7 · dimension 02 · not in the tool yet
25 of 9buildings on this page whose main light
the tool cannot see
the rooflight again

The whole building is a rooflight, read here through a stand-in.

The Bruder Klaus reading counted four of the studio's first eight buildings lit by something the light model does not read. Jewel, the ninth read, makes it five of nine, and it is the purest case: nine thousand panels of glass, nearly all of it overhead. The December dose of 0.69 in the table is from a stand-in, the dome's side read as a glazed wall, and it clears the threshold easily, as almost anything would at 1.36°N.

Near the equator the model's own question goes soft as well. It asks whether a room gets enough light in the darkest month, and in Singapore December and June differ by little. The real questions here are heat, glare and whether 3,000 trees get enough light to live, and none of them is a question the tool asks.

GENERATED FROM solar geometry for 1.36°N on a stand-in wall · circadian stimulus 09:00 to 17:00 · dimension 03 · the rooflight case is not in the tool
3100view reading, Vortex floor and forest trail
the highest on this page
the pillar it can test

The one claim the tool can test, and the building passes it completely.

The view model multiplies how much of the field of view is outside the room by what is in it, with planting counted in, after Ulrich's 1984 window study and later work on natural views. Under the dome every direction is trees, and both zones score the maximum, the first 100 on this page. The ring of shops, which looks into the forest across a balustrade, still scores 83.

What the model cannot do is tell a forest from a planted atrium, or know that the benefit Ulrich measured was for patients recovering from surgery, not for travellers with a flight to catch. It confirms that the view is there. Whether the view does what biophilic design says it does, for these people, is a question for a study with people in it.

GENERATED FROM view fraction × content, planting · Ulrich 1984 · dimension 07
430basement retail floor, total reading
light 0 · view 18
lowest zone here

The famous quarter, and the ordinary rest.

The Forest Valley and the Canopy Park together are about 36,000 m² of a published 135,700 m², about a quarter. The rest is shops, restaurants, a hotel and airport facilities, and the floors below ground see neither sky nor forest. Read as one of those floors, the building scores 30: no daylight, a view of 18, and the same four seconds of reverberation as any hard-finished mall.

This is not a criticism of the forest. It is the reminder that a building is judged by its photograph and lived in by the square metre. Most of the people in Jewel at any moment are not standing under the glass.

GENERATED FROM the four zone readings as run · published floor areas · nothing corrected

WHAT I WOULD CHANGEBelow ground, and nowhere else

The sweep offers twenty-five points across the scheme. Under the dome it proposes textile walls, on a wall made of glass, and wool at the hand, on balustrades that 300,000 people a day hold. Both refused. The basement row is the one worth taking to a client.

ZoneWhat the sweep proposesNowAfter
The Rain Vortex floorWool at the hand5660
Forest Valley trailWool at the hand · textile walls5786
Retail ring2700 K lamps · heavy planting · wool at the hand · slatted ceiling5486
Basement retail floor2700 K lamps · heavy planting · wool at the hand · slatted ceiling3066

Warmer lamps, an absorbent ceiling and planting on the floors that cannot see the forest would bring a little of the dome down to the people who are not under it. The wool is refused everywhere: in a building this busy the hand needs a surface that can be cleaned, not a soft one. The trail's twenty-nine points are the tool asking to line a glass dome with fabric.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. The large dimensions are published; every zone inside them is scaled from photographs and description, ±20% at best.
  • The volume. A 150 × 200 × 40 m box is larger than the real dome, so every sound figure under the glass is an upper bound.
  • The water. A constant 40 m waterfall is the loudest thing in the building and the tool has no sound sources, only decay.
  • The climate. The dome is kept comfortable for people and for plants; there is no thermal model and no humidity.
  • The crowd. 300,000 a day is an average across a day; the occupancies here are guesses at a busy moment.

What it can show is an instrument meeting a building whose main materials are water, leaves and glass, and getting the one of the three it was built for, the view, exactly right. The other two it reads as concrete. That is the most useful sentence in this section, because it names the next two things the tool needs.

04 · INDEPENDENT STUDYChurch of the Light

A concrete box with a cross cut into the wall behind the altar. The sun draws the whole cross in light on spring and summer mornings, and never in December.

Tadao Ando1989 · SUNDAY SCHOOL ADDED 1999
Ibaraki, Osaka · 34.83°NJAPAN · A WORKING CHURCH
WorshipBUILDING TYPE · SETS THE WEIGHTS
BuiltWALLS 38 CM OF IN-SITU CONCRETE
2 zonesTHE CHAPEL AND THE WAY IN

Open the church in the reading tool →Two zones, as with the Bruder Klaus chapel. The cross wall faces east, as published. · See the building → · Wikipedia →

The cross of light cut through the east wall, over the pewsimages/research-church-light-cross-full.jpg · 1600 × 900Credit: Bergmann, CC BY-SA 3.0
Photograph: Bergmann, CC BY-SA 3.0, via Wikimedia Commons
The cross cut through the east wall of the chapel in Ibaraki, Osaka: the only light in the room, falling across the pews.

What the numbers stand on

The box is published to the centimetre. Almost everything else about the room is in the photographs, not in the drawings.

KNOWN · PUBLISHED

  • Completed 1989 in Ibaraki, about 25 km north-north-east of Osaka; a Sunday school was added in 1999
  • Three 5.9 m concrete cubes in a row, 5.9 × 17.7 × 5.9 m, about 113 m²; walls 38 cm of in-situ concrete
  • A wall set at 15° cuts across the box and separates the entrance from the chapel
  • The cross is cut through the wall behind the altar, floor to ceiling and wall to wall; floor boards and benches are made from reused scaffolding boards

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The chapel read as two of the three cubes, 5.9 × 11.8 × 5.9 m, with forty people
  • The way in read as a slot 1.8 m wide and 11 m long beside the angled wall, with four people
  • The cross read as openings about 0.2 m wide, which is 7% of the wall
  • The cross wall faces east, as published; the slots taken as 0.2 m wide and the horizontal arm at 3.8 m, scaled

MAPPED · AND WHAT THE TOOL LACKS

  • Concrete ceiling and walls; scaffold boards → timber floor; the benches → oak at the hand
  • Contrast. The model averages daylight over the working day; it has no term for a single bright line in a dark room. Finding 1
  • Singing. One target for every gathering, set for speech. Finding 2
  • Lamp 3000 K for the few fittings; grey for the concrete

Research card

Study 04 · Read

Problem
Ando's concrete box, with a cross cut through the 38 cm east wall behind the altar.
Question

When does the sun actually draw the cross in light?

Method and analysis
Method
The sun traced through each arm of the cross at 34.83°N through the year. Slot width scaled from photographs and swept from 0.15 to 0.25 m.
Analysis
Compared: Date, time of day, slot width. Measured: Minutes of the whole cross in sunlight; how close the patch of light comes to the altar.
Finding
About 129 minutes at the March equinox and 133 in June; none in December. The patch walks up the aisle and stops 6.1 m short of the altar.
Design implication
The wall's depth is a design decision: it chooses the seasons in which the cross appears.

THE ZONESA room, and the sun through its one opening

The chapel is one volume and the way in is a narrow slot beside the angled wall, so it is read as two zones, as the Bruder Klaus chapel was. The drawings go further than the zones: they follow the sun through the cross, because the cross is the building.

The chapel cut along its length, looking north, to scale. On the March equinox the first sun through the horizontal arm lands on the back wall; as the sun climbs, the patch comes down onto the floor and walks up the aisle towards the altar, until the 38 cm depth of the wall cuts it off. Every ray is computed from the sun's position; the arm's height and width are scaled. The figure is the median adult, 1.685 m.
Plan, north up, to scale. The shaded arc is the only part of the sky from which direct sun can pass straight through the vertical arm. The March and June sunrises are inside it. The December sunrise is not, so in midwinter the vertical arm never carries the sun and the cross never forms. The angled 15° wall is not drawn: its exact position is not published in a form the studio could scale.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
The chapelGather5.9 × 11.8 × 5.9east, 7% · blankconcrete · concrete · timberoakgrey · 3000 K
The way inMove through1.8 × 11 × 5.9noneconcrete · concrete · concretesteelgrey · 3000 K

The cross is the only opening in the chapel and it is read as 7% of an east wall. The way in has no window of its own and reads as none.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for worship. The chapel is dark by design and the tool scores it as a dark room; the way in is darker still.

WHAT THE READING FOUNDThree things about a room built around one line of light

1129 · 0minthe whole cross in sunlight after sunrise
March equinox · December solstice
computed

In December the cross of sunlight never forms.

Each arm of the cross is a slot through 38 cm of concrete, and a slot only passes direct sun while the sun is nearly square to it. With slots 0.2 m wide, the vertical arm sees the sun only within 27.8° either side of due east. The March and June sunrises are inside that arc, and the whole cross lands in sunlight for about 129 and 133 minutes. The December sun rises at 120°, outside it, and never comes back: the vertical arm carries no direct sun at all, and only the horizontal arm is lit.

The slot width is scaled from photographs, so the result is given with its range: at 0.15 m the December cross never forms, at 0.25 m it forms for 28 minutes. Either way, the cross of sunlight is a spring and summer event, and in winter the cross is seen only as a glowing opening, not as light on the floor.

GENERATED FROM solar geometry for 34.83°N · slot passes sun within atan(width ÷ depth) of its normal · width scaled 0.15 to 0.25 m · dimension 03
26.1mnearest the sun through the horizontal arm
gets to the altar wall, March equinox
it never arrives

The patch of light walks up the aisle and stops six metres short of the altar.

At sunrise the light through the horizontal arm lands high on the back wall, behind the congregation. As the sun climbs it drops to the floor and moves up the aisle towards the altar: 9.2 m from the east wall at 07:30 solar time, 6.8 m at 08:00, 6.1 m at 08:12. Then the sun rises past 27.8° in profile and the depth of the wall cuts it off.

So the morning light travels towards the altar and never reaches it. Whether Ando meant that, the drawing cannot say. That it happens every clear spring morning, it can.

GENERATED FROM solar geometry for 34.83°N · ray traced through the arm onto the stepped floor · arm height 3.8 m, scaled · dimension 03
30.15December circadian dose, the chapel
threshold 0.30 · light scored 54
right, and beside the point

The dark is the design, and the reading says so rather than asking for more light.

Averaged over the working day, the cross gives the chapel 0.15 in December, half of what the circadian model wants for a body, and the light reading comes back 54. Every part of that is correct and none of it is useful: a room lit to the model's threshold would lose the cross. It is the position the Jewish Museum reading reached with the Holocaust Tower, a number that is right and a change that would be indefensible.

GENERATED FROM solar geometry for 34.83°N · circadian stimulus 09:00 to 17:00 · dimension 03

WHAT I WOULD CHANGENothing

The sweep offers heavy planting and a slatted ceiling in the chapel, and wool and timber walls on the way in. In a room made of one material and one opening, all of it is refused.

ZoneWhat the sweep proposesNowAfter
The chapelHeavy planting · slatted ceiling5070
The way inHeavy planting · wool at the hand · timber walls3362

A slatted ceiling would shorten the reverberation, which the tool wants, and flatten the singing, which the congregation does not. Planting in front of the cross is not a move anyone should make.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. The box is published; the split into two zones is estimated.
  • The slot widths and the arm height. Both are scaled from photographs; finding 1 gives the range they move the result through.
  • Cloud. Every ray in the drawings assumes a clear sky.
  • The Sunday school of 1999 is not read.

What it can show is a tool that is right about a room in every number and wrong about what the room is for. It is the clearest case on this page of why a reading has to be read by someone.

14 · INDEPENDENT STUDYLouisiana Museum of Modern Art

A museum that is mostly a walk through a park. Its glass corridor is the best room on this page; a closed gallery is one of the worst.

Jørgen Bo · Vilhelm Wohlert1958 · WINGS 1966, 1971, 1982
Humlebæk · 55.97°NDENMARK · ON THE ØRESUND COAST
GalleryBUILDING TYPE · SETS THE WEIGHTS
BuiltABOUT 700,000 VISITORS A YEAR
4 zonesA CORRIDOR, TWO GALLERIES, A CAFÉ

Open Louisiana in the reading tool →Loads the four zones as read here. The corridor's height is scaled, and finding 1 shows how much it matters. · See the building → · Wikipedia →

The glass corridor between the galleries, open to the gardenimages/research-louisiana-glass-corridor.jpg · 1920 × 1080Credit: kallerna, CC BY-SA 4.0
Photograph: kallerna, CC BY-SA 4.0, via Wikimedia Commons
The glass corridor between the galleries: glass floor to ceiling, white brick, the park as the view. The condition the tool rates highest.

What the numbers stand on

The history is published in detail. The rooms are not dimensioned in anything public, so every zone is scaled from photographs.

KNOWN · PUBLISHED

  • Opened 1958 as three buildings joined by glass corridors, in an old estate on the Øresund coast about 30 km north of Copenhagen
  • The West Wing added in 1966 and extended in 1971; the South Wing in 1982 for larger works; a concert hall in 1976
  • A sculpture garden above the sea; a three-storey children's wing, a restaurant and a shop
  • About 700,000 visitors a year; 715,820 in 2024

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The corridor as 30 × 3 × 2.6 m, glazed along one side to the park, fifteen people
  • The Giacometti gallery as 10 × 12 × 5 m with a window to the garden, twenty-five people
  • A South Wing gallery as 20 × 30 × 4.5 m with no window, sixty people
  • The café as 15 × 10 × 3 m, glazed towards the sound, sixty people

MAPPED · AND WHAT THE TOOL LACKS

  • White-painted brick → plaster; timber ceilings; tiled floors → stone; oak at the hand, all from photographs
  • The sea. The view model has trees, sky, buildings and blank. Water is read as sky
  • Rooflights, if the South Wing has them. Read with no window, which is what the tool would see anyway
  • Lamp 3000 K in the galleries, 2700 K in the café

Research card

Study 14 · Read

Problem
Glass corridors joining galleries on the Øresund coast, about 700,000 visitors a year.
Question

In a museum that is mostly a walk through a park, which room reads best?

Method and analysis
Method
Four zones of a visit, corridor, two galleries and the café, scaled from photographs. Corridor height swept from 2.2 to 3.4 m. Six models, weighted for a gallery.
Analysis
Compared: Corridor ceiling height, window or none, orientation. Measured: Total reading, scale reading by height, December dose.
Finding
The glass corridor scores 83, the highest zone on this site, and 73 to 85 as its height runs from 2.4 to 2.8 m. The north-lit gallery gets 0.07 of a December dose.
Design implication
Thirty centimetres of ceiling separate the best room from an ordinary one. Gallery light needs its own target.

THE ZONESA corridor at every height, and a walk as a rhythm

The reading follows a visit: the corridor, a gallery that looks out, a gallery that does not, and the café by the water. The dimensions are scaled from photographs, and the corridor's height is the one that matters most.

The corridor cut across, to scale, galleries on the left and the park through the glass on the right. Beside it, the tool's scale reading for every ceiling height from 2.2 to 3.4 m, each bar drawn at the height it belongs to. The reading is steep exactly where this corridor sits: 17 at 2.3 m, 88 at 2.6 m, 100 by 2.8 m. The figure is the median adult, 1.685 m.
A visit as a rhythm, in an illustrative order: glass, gallery, closed gallery, glass. At the top, the ceiling line along the walk, heights exaggerated three times, glazed stretches in lilac. Below, three readings from the tool as stepped traces on the same distance axis: December daylight against the 0.30 a body needs, view, and reverberation. Where the walk opens to the park or the sea, all three move together.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Glass corridorMove through30 × 3 × 2.6west, 90% · treestimber · plaster · stoneoakwhite · 3000 K
Giacometti galleryGather10 × 12 × 5north, 50% · treestimber · plaster · stoneoakwhite · 3000 K
South Wing galleryGather20 × 30 × 4.5noneplaster · plaster · stoneoakwhite · 3000 K
Café over the soundGather15 × 10 × 3east, 70% · skytimber · plaster · stoneoakwhite · 2700 K

The sea is entered as sky, the nearest view the tool has. The South Wing gallery is read as closed; if it has rooflights, the tool could not see them in any case.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a gallery. The two zones that look out score 83 and 79; the two galleries score 58 and 42.

WHAT THE READING FOUNDThree things about a museum that is mostly a walk

183glass corridor, total reading
73 to 85 as the height runs 2.4 to 2.8 m
highest zone on this page

The best room on this page is a corridor.

Light 99, sound 83, scale 88, material 90, view 100. At the height scaled from photographs, 2.6 m, the ceiling sits at 1.55 median bodies, the comfortable ratio dimension 09 derived. Every model agrees about it, and it is the highest zone on this page.

The honest caveat is in the stat: the height is scaled, and the scale reading is steep near that ratio. At 2.4 m the corridor totals 73; at 2.8 m, 85. The drawing shows why: the scale reading is 88 at 2.6 m, 41 at 2.4 m and 17 at 2.3 m, and it is already 100 by 2.8 m. Thirty centimetres of ceiling is the difference between the best room on this page and an ordinary one, and the corridor sits on exactly that slope. It stays the highest zone here anywhere in the range, but the exact figure is only as good as the photograph it came from.

GENERATED FROM the six models on the corridor as scaled · height swept 2.4 to 2.8 m · dimension 09
20.07December dose, the Giacometti gallery
threshold 0.30 · light 39
the conservator's choice

At 56 degrees north, a window facing north gives almost nothing in December.

The gallery is read with a north window, and in a Danish December it passes 0.07, a quarter of what the model wants for a body. The model is right about the body, and its threshold is written for people who spend a working day in a room.

A visitor passes through in minutes, and a gallery often keeps daylight low on purpose. The number describes the room correctly and the target does not fit the use, which is a gallery-weighting question the tool has not been asked before.

GENERATED FROM solar geometry for 55.97°N · circadian stimulus 09:00 to 17:00 · dimension 03
383 → 42the corridor · the closed South Wing gallery41 points apart

The walk and the box are forty-one points apart.

Read with no window, hard plaster and stone, the South Wing gallery gives 5.37 seconds of reverberation, no daylight, and a view of 18. It was built in 1982 for larger works, and large works need walls and control of light, which is a real reason.

The tool cannot weigh that reason. What it can show is how much of what visitors say about Louisiana is the corridor and the park, and how little of it is any single gallery.

GENERATED FROM the four zone readings as run · gallery weights · nothing corrected

WHAT I WOULD CHANGEA ceiling in the South Wing, and nothing else

The sweep proposes 6500 K lamps and magnolia paint everywhere, textile walls in the Giacometti gallery, and carpet in the café. The lamp and wall colours are the curators' decisions, not the tool's.

ZoneWhat the sweep proposesNowAfter
Glass corridor6500 K lamps · magnolia walls8385
Giacometti gallery6500 K lamps · magnolia walls · textile walls5876
South Wing gallery6500 K lamps · heavy planting · magnolia walls · slatted ceiling4263
Café over the sound6500 K lamps · heavy planting · magnolia walls · carpet7987

The one move worth a conversation is an absorbent ceiling in the closed galleries, which would bring 5.37 seconds down to a room people can talk in without changing a wall the art hangs on. The rest is the tool redecorating a museum.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. Every dimension is scaled from photographs, ±20%, and finding 1 shows the result can move with one of them.
  • The sea. The best view the building has is read as sky.
  • The art. The tool reads the room and never the work in it.
  • The South Wing is read as closed. If it has rooflights, the light reading runs low, the same way it does for every rooflit room on this page.

What it can show is that the highest reading on a page of famous buildings belongs to a corridor. That is a finding about Louisiana, and also about what these six models value: light, a view out, a ceiling at body height, and something warm to touch.

06 · INDEPENDENT STUDYSydney Opera House

Two concert halls, read by a tool built for speech, and a foyer facing the sun, because in Sydney the sun is in the north.

Jørn Utzon1973 · COMPLETED BY PETER HALL
Bennelong Point · 33.86°SSYDNEY, AUSTRALIA · SOUTHERN HEMISPHERE
GalleryTHE TOOL HAS NO TYPE FOR A PERFORMANCE VENUE
BuiltCONCERT HALL RENEWED 2022
3 zonesTWO HALLS AND THE FOYER

Open the Opera House in the reading tool →Loads the three zones as read here. The halls are scaled boxes; finding 1 says what that does to the sound. · See the building → · Wikipedia →

The northern foyer under the concrete ribs, glass walls onto the harbourimages/research-sydney-interior.jpg · 1920 × 1080Credit: Larry Koester, CC BY 2.0
Photograph: Larry Koester, CC BY 2.0, via Wikimedia Commons
The only room in the reading with a view. North-facing, which in Sydney means facing the sun.

What the numbers stand on

The building is published in great detail. The halls' volumes are not given in any source the studio checked, so they are scaled.

KNOWN · PUBLISHED

  • Opened 20 October 1973; 183 × 120 m; the roof rises to 67 m above sea level from 2,194 precast sections, tiled with 1,056,006 tiles
  • Concert Hall 2,679 seats; Joan Sutherland Theatre 1,507; interiors in white birch plywood and brush box
  • The northern foyers are glass walls facing Sydney Harbour
  • The Concert Hall renewal, completed 2022 (ARM Architecture, with Müller-BBM, Arup and others), added 18 reflector "petals" over the stage, a new ceiling and absorbent hangings to reduce reverberation

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The Concert Hall as a 45 × 60 × 25 m box, full, 2,679 people
  • The Joan Sutherland Theatre as 30 × 35 × 18 m, full, 1,507 people
  • The northern foyer as 40 × 20 × 20 m, glazed to the north, four hundred people
  • The hall volumes are the largest uncertainty in this reading

MAPPED · AND WHAT THE TOOL LACKS

  • Birch and brush box → timber on every surface of the halls; upholstered seats → wool at the hand
  • A target for music. The tool has one target for gathering, set for speech. Finding 1
  • A type for a venue. Read as a gallery, the nearest weights the tool has. Finding 3
  • Granite paving → stone in the foyer; the harbour → sky

Research card

Study 06 · Read

Problem
Utzon's halls under the shells. The 2022 renewal of the Concert Hall added reflectors and absorbent hangings.
Question

How does a tool built around speech read two halls built for music?

Method and analysis
Method
Both halls read full as scaled boxes, the northern foyer at an interval. Reverberation swept against hall volume; noon sun traced on three dates.
Analysis
Compared: Hall volume; season, in the southern hemisphere. Measured: Reverberation, winter circadian dose, how far the sun reaches.
Finding
Both halls read 38. The Concert Hall rings 4.96 s as a box and would reach 2 s at about 20,500 m³. The north foyer gets 0.66 in June, twice the threshold.
Design implication
The tool needs a target for music and a type for a venue. North glass in Sydney takes the winter sun and keeps the summer out, without shading.

THE ZONESA foyer that faces the sun, and a hall of unknown volume

The two main halls are read as full, as they are when they matter. The foyer is read at an interval, with four hundred people in it. The halls are scaled boxes; the real volumes are shaped by the shells and are smaller.

The northern foyer cut through, to scale, at solar noon on three dates. At 33.86°S the winter sun comes low from the north: on 21 June it stands at 32.7° and crosses the whole 20 m foyer to the back wall. On 21 December it stands at 79.6° and reaches only 3.7 m in. The glass is drawn upright; the real walls lean out from the shells. The figure is the median adult, 1.685 m.
Above, the Concert Hall as the tool reads it: a 45 × 60 × 25 m box of timber with 2,679 people, schematic. Below, what the same finishes and audience give as every dimension shrinks. The box gives 4.96 s; the curve reaches the two seconds concert halls are built for at about 20,500 m³. The real hall's volume is not in any source the studio checked, so the curve is the honest answer: the reading depends on a number nobody has published here.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Concert HallGather45 × 60 × 25nonetimber · timber · timberwooloak · 3000 K
Joan Sutherland TheatreGather30 × 35 × 18nonetimber · timber · timberwooloak · 3000 K
Northern foyerGather40 × 20 × 20north, 90% · skyconcrete · concrete · stonesteelcream · 3000 K

The halls have no windows. The foyer faces north, the sun side in the southern hemisphere, and the tool reads June as its winter.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a gallery because the tool has no type for a performance venue. Both halls come back 38 for the same two reasons.

WHAT THE READING FOUNDThree things about two halls and a view

14.96sConcert Hall, read as a box, full
target for gathering 0.6–0.9 s
the wrong target

A concert hall is meant to ring, so the reading asks for a music target.

The tool has one target for a gathering, 0.6 to 0.9 seconds, which is the right target for a lecture. A symphony hall is designed to ring for far longer than that, so a hall that met the tool's target would be a failed concert hall. The 4.96 seconds here is also an upper bound, because the hall is read as a box larger than the room under the shells.

The drawing puts a number on how wrong the box is: with the same timber and the same audience, the hall would ring for two seconds at about 20,500 m³, less than a third of the box. The one thing the tool and the building agree on is the direction. The 2022 renewal added absorbent hangings to reduce reverberation. The tool would have asked for that too, and for a much larger amount, which is exactly why it needs a target for music before it reads another hall.

GENERATED FROM Sabine T60 on the scaled volume and stated finishes · dimension 02 · no music target in the tool
20.66winter dose, the northern foyer
read for June, the southern winter
the hemisphere, handled

In Sydney the sun is in the north, and the tool knows it.

Every other building on this page is in the northern hemisphere, where a north window is the dim one. Here the foyer's glass faces north into the sun, and the model reads June as winter. It gives 0.66, more than twice the threshold, and a light score of 100. The section shows what that means in the room: at noon on 21 June the sun stands at 32.7° and crosses all twenty metres of the foyer to the back wall; on 21 December it stands at 79.6° and gets 3.7 m in. The glass lets the winter in and keeps the summer out, without a single shading device.

It is worth saying because it is the first time the page has tested that part of the model on a real building, and it passed.

GENERATED FROM solar geometry for 33.86°S · winter taken as June · circadian stimulus 09:00 to 17:00 · dimension 03
338 · 38total reading, both halls
light 0 · view 18 · sound 0
the type is missing

A 38 for a concert hall writes the brief for a performance building type.

Both halls lose their light and view readings because they have no windows, which is correct for a hall, and their sound because the target is for speech. Weighted as a gallery, which is the nearest type the tool has, that is enough to put two of the best-known halls in the world at 38.

The tool needs a performance type, with no weight on daylight or view and a music target for sound. Until then its totals for halls should not be published without this paragraph, so this paragraph is published.

GENERATED FROM the three zone readings, gallery weights · nothing corrected

WHAT I WOULD CHANGENothing the renewal did not already do

The sweep proposes 6500 K lamps, heavy planting and magnolia walls in both halls, and wool at the hand in the foyer. All of it is refused.

ZoneWhat the sweep proposesNowAfter
Concert Hall6500 K lamps · heavy planting · magnolia walls3848
Joan Sutherland Theatre6500 K lamps · heavy planting · magnolia walls · textile walls3859
Northern foyer6500 K lamps · heavy planting · wool at the hand5264

The building's own renewal is the better answer than anything the sweep has: acoustic work designed by specialists, tested with musicians, and reversible where it can be. The tool would have painted the birch.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. Seat counts and the building's size are published; the hall volumes are scaled and are the largest uncertainty here.
  • Music. There is no target for it, finding 1, so every sound figure in the halls is measured against the wrong line.
  • The renewal's reflectors and hangings are not in the reading. The halls are read as timber boxes.
  • The harbour. Read as sky, because the tool has no water.

What it can show is the same honest failure the Sagrada Família showed at the top of the page, now in its purest form: an instrument built for rooms people work in, reading rooms built for music, and returning precise numbers that should not be used.

15 · INDEPENDENT STUDYCopenHill

A waste-to-energy plant with a ski slope on its roof. Most visitors are outside on the slope, and its clean energy is a separate question from how it feels.

BIGPLANT 2017 · ROOF PARK 2019
Amager, Copenhagen · 55.68°NDENMARK · A PUBLIC ROOF
CampusTHE TOOL HAS NO TYPE FOR A POWER PLANT
BuiltWORLD BUILDING OF THE YEAR 2021
3 zonesA MACHINE HALL, A BAR, A SLOPE

Open CopenHill in the reading tool →Loads the three zones as read here. The slope is outdoors and is read as a box; finding 2 is why that figure is set aside. · See the building → · Wikipedia →

The plant from the water, its roof rising as a ski slopeimages/research-copenhill-facade.jpg · 1920 × 1080Credit: kallerna, CC BY-SA 4.0
Photograph: kallerna, CC BY-SA 4.0, via Wikimedia Commons
The building's public face, which is also its roof, and outdoors.

What the numbers stand on

The plant is published as a plant: tonnes, megawatts, metres of height. Its interiors are not, so the zones are scaled.

KNOWN · PUBLISHED

  • A combined heat and power plant burning about 400,000 tonnes of waste a year, for electricity and district heating
  • 85 m tall; a year-round artificial ski slope, a hiking trail and an 80 m climbing wall on the façade
  • The plant opened in 2017 and the recreation areas in 2019
  • World Building of the Year at the World Architecture Festival, 2021

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The boiler hall as 40 × 100 × 60 m, ten people, scaled from the building's height
  • The rooftop bar as 20 × 15 × 4 m, eighty people, glazed to the west
  • The slope read as a 60 × 400 × 20 m box, a hundred and fifty people; it is outdoors
  • Every interior dimension here is an estimate

MAPPED · AND WHAT THE TOOL LACKS

  • Steel, concrete and aluminium → concrete for sound; the slope's artificial surface → concrete
  • The bar assumed timber throughout, from photographs; not confirmed
  • Machine noise. The tool reads decay, not sources. Finding 1
  • Energy and carbon. None of the six models reads either. Finding 3

Research card

Study 15 · Read

Problem
BIG's waste-to-energy plant: 85 m tall, a public slope on the roof, and best known for its energy.
Question

What can a perceptual reading say about a power plant with a ski slope on its roof?

Method and analysis
Method
Three zones, the boiler hall, the rooftop bar and the slope, scaled from the building. The published energy figures drawn separately.
Analysis
Compared: Indoor against outdoor zones. Measured: Reverberation, light and view; heat and electricity from published figures.
Finding
The rooftop bar is the one zone the six models describe well. The slope is outdoors, so its sound figure is set aside. None of the six models reads energy or carbon.
Design implication
How a space is perceived and how it performs are separate claims, and a study should keep them apart.

THE ZONESA hill read as a room, and the energy beside it

The plant is read once for the people who work in it, the bar for the people who come for the view, and the slope for the people who come to ski. Only the bar is the kind of room the tool was built for.

CopenHill as a hill, schematic. Heights are published, lengths are not. The slope, in amber, is where most visitors are, and it is outdoors. Dashed over it is what the reading tool actually reads there: a room with a 20 m ceiling, because it has no outdoors. The boiler hall and the bar are the zones as read. The figure is drawn six times the building's scale so it can be seen at all: at true scale the building is 50 bodies tall.
What the building is for, drawn only from its published figures: about 400,000 tonnes of waste a year in, and at maximum 247 MW of district heat and 63 MW of electricity out. Four fifths of what it can produce is heat for the city. Band widths are shares of the published maximum output, not of any year's actual output.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Boiler hallCreate40 × 100 × 60west, 30% · builtconcrete · concrete · concretesteelgrey · 4000 K
Rooftop barGather20 × 15 × 4west, 80% · skytimber · timber · timberoakoak · 2700 K
Ski slopeMove through60 × 400 × 20south, 90% · skyconcrete · concrete · concretesteelgrey · 6500 K

The slope is outdoors. It is read as a box because the tool has no outdoors, and its sound reading is meaningless. The boiler hall's occupancy is a guess.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a campus, the nearest type the tool has. The bar is the one zone the readings describe well.

WHAT THE READING FOUNDThree things about a power plant with a park on it

176sreverberation, the boiler hall
read as a sealed box, ten people
the wrong question

The loudest room here is loud because of what is in it, not how long it rings.

Sixty metres of concrete and steel read as a box gives 76 seconds, the longest figure on this page. It is also the least useful: in a working hall the question is the noise of the machines, and the tool reads how long a sound lasts, not what is making it.

Jewel's waterfall made the same point from the other side. Twice now, the loudest thing in a building has been a source the tool does not have.

GENERATED FROM Sabine T60 on the scaled volume and stated finishes · dimension 02 · no sound sources in the tool
254.95sreverberation, the ski slope
outdoors, read as a box
meaningless

The busiest zone is outdoors on the slope, and its sound figure is set aside.

A hillside open to the sky cannot ring for fifty-five seconds, and the tool says it does because it can only read a room. The Garden of Exile at the Jewish Museum was the first outdoor zone read as a box on this page; this is the second, and the more important, because it is where most of CopenHill's visitors are.

The other readings for the slope, light 100 and view 69, are reasonable because they do not depend on walls. Sound and scale do, and both are printed here only to show what the tool does when it meets an outside.

GENERATED FROM the slope zone as run · dimension 02 and dimension 09 · no outdoor case in the tool
30 of 6models that read energy or carbon
the claim the building is known for
the sustainable pillar

The building is famous for its energy, which a perceptual reading leaves to other tools.

CopenHill is known as a clean waste-to-energy plant that gives the city a park. The six models read light, sound, scale, material, colour and view. None reads energy, emissions or carbon, so the building's main claim is invisible in every number above. The second drawing shows what that claim is, from the published figures alone: up to 247 MW of heat and 63 MW of electricity from about 400,000 tonnes of waste a year. Four fifths of it is heat for the city, which is a fact about how Copenhagen lives in winter and not about any room in this building.

This is the gap the studio's own Pillars page names: sustainable design is the thinnest of the four pillars, with no dimension of its own yet. A building like this is the argument for building one.

GENERATED FROM the six models as they stand · see the Pillars page · no energy or carbon model yet

WHAT I WOULD CHANGEAn absorbent ceiling in the bar

The sweep proposes warm lamps, planting and wool in the boiler hall, and wool on the slope. Both refused. In the bar it proposes daylight lamps, planting and a slatted ceiling.

ZoneWhat the sweep proposesNowAfter
Boiler hall2700 K lamps · heavy planting · wool at the hand4455
Rooftop bar6500 K lamps · heavy planting · slatted ceiling7388
Ski slope2700 K lamps · wool at the hand5663

The slatted ceiling in the bar is the only move here worth a conversation: 1.75 seconds of reverberation in a room of eighty people is loud, and timber slats fit the room. The rest is the tool furnishing a machine and carpeting a hill.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. Every interior dimension is scaled, and the boiler hall is barely published at all.
  • The slope is outdoors, finding 2.
  • Machine noise, finding 1.
  • Energy and carbon, finding 3: the thing the building is for.

What it can show is the edge of a perceptual tool. It can say that the bar is a good room and the machine hall is a hard one. It cannot say whether CopenHill is a good building, because what makes it one is outside all six models.

08 · INDEPENDENT STUDYHarpa

A concert hall behind coloured glass at 64° north. Its glass foyer gets almost enough winter light, from about four hours of December sun.

Henning Larsen · Batteríið2011 · FAÇADE WITH OLAFUR ELIASSON
Reykjavík · 64.15°NICELAND · ON THE HARBOUR
GalleryTHE TOOL HAS NO TYPE FOR A PERFORMANCE VENUE
BuiltACOUSTICS BY ARTEC
3 zonesTHE MAIN HALL, THE FOYER, A SMALL HALL

Open Harpa in the reading tool →Loads the three zones as read here. The coloured glass reads as clear; finding 2 is why. · See the building → · Wikipedia →

The foyer inside the hexagonal glass façade, under the mirrored ceilingimages/research-harpa-foyer-stair.jpg · 1920 × 1080Credit: Marcos H. Mujunen, Pexels
Photograph: Marcos H. Mujunen, via Pexels
The foyer the façade was made for: hexagonal glass on one side, the mirrored ceiling overhead, and the colour the tool cannot read.

What the numbers stand on

Seat counts and the building's size are published. The halls' dimensions are not, so they are scaled.

KNOWN · PUBLISHED

  • Opened 13 May 2011; Henning Larsen Architects with Batteríið, the façade with Olafur Eliasson, acoustics by Artec
  • About 28,000 m² and 43 m high
  • Eldborg 1,600 to 1,800 seats; Silfurberg 750; Norðurljós 450; Kaldalón 195
  • A façade of geometric glass panels in several colours, drawing on basalt columns, with 714 LED lights

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • Eldborg as a 30 × 40 × 25 m box, 1,600 people
  • The foyer as 60 × 20 × 30 m, glazed to the south, three hundred people
  • Kaldalón as 15 × 20 × 8 m, 195 people
  • All three volumes are estimates

MAPPED · AND WHAT THE TOOL LACKS

  • Eldborg's red interior → timber, and oak for colour: the colour model has no red
  • Upholstered seats → wool; stone floors in the foyer; glass → concrete for sound
  • Coloured glass. Read as clear. The second building on this page, after the Sagrada Família, whose light is coloured before it lands
  • A target for music. As at the Opera House

Research card

Study 08 · Read

Problem
Henning Larsen and Olafur Eliasson's coloured glass façade, at 64.15°N.
Question

How much winter light reaches a glass foyer near the Arctic Circle?

Method and analysis
Method
The sun computed for 21 June and 21 December; the foyer cut through the façade. Both halls read full as boxes.
Analysis
Compared: Date, glass colour (read as clear), hall volume. Measured: December circadian dose, sun angle and where the light lands, reverberation.
Finding
The foyer gets 0.28 in December, just under the 0.30 threshold. The low sun crosses the room and lands on the back wall, coloured. The halls ring 3.79 and 1.98 s.
Design implication
A second building whose light is coloured before it lands. The case for a spectrum input, and for a target for music, is made.

THE ZONESFour hours of sun, and a wall of coloured glass to catch them

The foyer is the space the façade makes, and it is read once, at an interval. Behind it the main hall and the smallest hall are read full. The halls are scaled boxes.

The sun at 64.15°N, in solar time, computed with the same geometry the reading tool uses. On 21 June it is up for more than twenty hours and reaches 49.3°. On 21 December it is above the horizon for about three and a half hours, about four with the bending of light in the atmosphere, and never climbs above 2.4°. The shaded band is the working day the circadian model averages over.
The foyer cut through the façade, scaled, open sky assumed. At December noon the sun stands at 2.4°, so it crosses the whole twenty metres almost level, through coloured glass, and lands on the back wall rather than the floor. In June it comes steeply down and still reaches the back wall. The coloured light is the part the tool cannot read. The figure is the median adult, 1.685 m.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
EldborgGather30 × 40 × 25nonetimber · timber · timberwooloak · 3000 K
Foyer behind the glassGather60 × 20 × 30south, 90% · skyconcrete · concrete · stonesteelcharcoal · 3000 K
KaldalónGather15 × 20 × 8nonetimber · timber · timberwooloak · 3000 K

The halls have no windows. The foyer is entered as a 90% glazed south wall; the glass is coloured, and the tool reads it as clear.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a gallery, the nearest type the tool has. The halls score like the Opera House's halls, for the same reasons.

WHAT THE READING FOUNDThree things about glass near the Arctic Circle

10.28December dose, the foyer
64.15°N · threshold 0.30
nearly

Nearly enough light, in a month with four hours of sun.

In a Reykjavík December the sun is up for about four hours, low in the south, and the first drawing shows how low: never above 2.4°. The foyer is almost all glass, and the model gives it 0.28, just under the threshold of 0.30. That is a large amount of light for the latitude, and it comes from building a room that is nearly all window.

The model averages 09:00 to 17:00, so the hours before sunrise and after sunset count as darkness, which they are. The number is fair to the room and to the place. What it misses is where that light goes: at 2.4° it does not fall on the floor at all. It crosses the room almost level and lands on the back wall, coloured by the glass it came through, which is the second drawing and the building's real winter event.

GENERATED FROM solar geometry for 64.15°N · circadian stimulus 09:00 to 17:00 · dimension 03
22 of 16buildings on this page whose light is coloured
before it reaches a surface
the Sagrada gap again

The façade colours the light, a second case for the colour model's next input.

The colour model multiplies a wall colour by a lamp temperature. Eliasson's façade colours the daylight itself, the same condition the Sagrada Família reading named as the colour model's next case to build. Harpa is the second building on this page where the main colour event is in the glass.

Two is enough to make it a pattern. The seventh input the Sagrada Família reading proposed, the spectrum of arriving light, would read both.

GENERATED FROM pigment × illuminant · dimension 06 · the coloured-light case is not in the tool
33.79 · 1.98sreverberation, Eldborg · Kaldalón
read as boxes, full
the wrong target

Two more halls make the case for a music target.

The same problem as the Opera House: the tool's target for a gathering is set for speech, and a concert hall is designed to ring longer. Eldborg comes back 3.79 seconds as a scaled box and Kaldalón 1.98, and both lose their sound reading.

Four halls on this page now ask for a music target. The case for it no longer needs making.

GENERATED FROM Sabine T60 on the scaled volumes · dimension 02 · no music target in the tool

WHAT I WOULD CHANGENothing

The sweep proposes daylight lamps, planting, magnolia paint and textile walls in both halls, and planting and wool in the foyer. All of it is refused.

ZoneWhat the sweep proposesNowAfter
Eldborg6500 K lamps · heavy planting · magnolia walls · textile walls3857
Foyer behind the glassHeavy planting · wool at the hand5661
Kaldalón6500 K lamps · heavy planting · magnolia walls · textile walls4464

Painting Eldborg magnolia would remove the one thing everyone remembers about it. The tool has no reason to know that, which is why a sweep is a list of options and not a list of recommendations.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. The halls are scaled boxes.
  • The coloured glass, finding 2.
  • Music, finding 3.
  • The façade at night. 714 LED lights make the building's winter face, and the tool reads daytime only.

What it can show is a building that answers its latitude with glass, and a tool that can measure how well it worked. That part it gets right. The colour and the music it cannot hear or see.

07 · INDEPENDENT STUDYVanDusen Botanical Garden Visitor Centre

A visitor centre shaped like an orchid, with a planted roof. It scores well for material and view, badly for sound, and one ceiling change fixes it.

Perkins&Will2011 · LANDSCAPE BY CORNELIA OBERLANDER
Vancouver · 49.24°NCANADA · IN THE BOTANICAL GARDEN
CampusTHE NEAREST TYPE FOR A VISITOR CENTRE
BuiltLEED PLATINUM · NET ZERO ENERGY TARGET
3 zonesTHE ATRIUM, THE CAFÉ, THE LIBRARY

Open the visitor centre in the reading tool →Loads the three zones as read here. The oculus is a rooflight and the tool cannot see it; finding 1. · See the building → · Wikipedia →

The entrance hall under the slatted timber roof and its oculusimages/research-vandusen-oculus.jpg · 1920 × 1080Credit: Daderot, CC0
Photograph: Daderot, CC0, via Wikimedia Commons
The entrance hall: the slatted timber underside of the petal roof, glass to the garden, a polished concrete floor. The slats are the kind of ceiling finding 2 says fixes the sound.

What the numbers stand on

The building is published mostly for its systems. The rooms are not dimensioned in public sources, so they are scaled.

KNOWN · PUBLISHED

  • Opened November 2011; about 1,810 m²
  • A roof of prefabricated "petals" carrying about 1,486 m² of native planting, over rammed earth and concrete walls and a glulam timber structure
  • A solar chimney with an operable glazed oculus at the centre of the atrium
  • Geothermal boreholes, photovoltaics and solar hot water, targeting net zero energy; rainwater and on-site blackwater treatment; LEED Platinum

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • The atrium as 20 × 20 × 7 m under the oculus, eighty people
  • The café as 15 × 10 × 4 m, glazed to the garden, fifty people
  • The library as 8 × 8 × 3.5 m, six people
  • All three from photographs

MAPPED · AND WHAT THE TOOL LACKS

  • Rammed earth → lime, the nearest porous wall the tool has; timber ceilings; concrete floors; oak at the hand
  • The oculus. A rooflight reads as no window. The atrium's light is entered through a south wall instead. Finding 1
  • Energy, water and air. None of the six models reads them; the stack speeds in the drawing are computed by hand. Finding 3
  • Beige and oak for colour; lamp 3000 K

Research card

Study 07 · Read

Problem
A visitor centre of rammed earth and glulam timber under a planted roof, with a solar chimney at its centre.
Question

Is natural material in conflict with a room people can talk in?

Method and analysis
Method
Three zones scaled from photographs. Every combination of five walls and five ceilings read for the atrium; the stack ventilation computed by hand.
Analysis
Compared: Wall finish; ceiling finish, solid or slatted. Measured: Reverberation, material reading, air speed through the oculus.
Finding
The atrium rings for 4.07 s and scores 0 on sound. Change only the ceiling, from boards to slats of the same timber: 1.36 s, and the material reading moves by one point.
Design implication
The trade-off between natural material and a room you can talk in is one surface wide.

THE ZONESA solar chimney, and a trade-off that turns out to be one surface

The atrium under the oculus is the centre of the building, the café faces the garden, and the library is the one room for sitting still. The dimensions are scaled from photographs.

The atrium cut through the oculus, schematic. Air comes in low, warms, rises and leaves through the oculus, the solar chimney. Its speed there, from the stack formula for a 7 m stack (scaled): 0.41 m/s when the inside is 1 K warmer than outside, 0.71 m/s at 3 K, 0.92 m/s at 5 K. None of this is in the reading tool, which has no air. The figure is the median adult, 1.685 m.
Every combination of five walls and five ceilings for the atrium, read by the tool. Colour is the wall. The solid ceilings sit at sound 0 whatever the walls are made of. Keep the rammed earth and change only the ceiling, from boards to slats of the same timber, and sound goes from 0 to 72 while material drops from 85 to 84. The conflict between natural material and a room you can talk in is in the ceiling, not in the earth.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Atrium under the oculusGather20 × 20 × 7south, 40% · treestimber · lime · concreteoakbeige · 3000 K
CaféGather15 × 10 × 4west, 60% · treestimber · lime · concreteoakoak · 3000 K
LibraryFocus8 × 8 × 3.5north, 30% · treestimber · lime · concreteoakoak · 3000 K

The oculus cannot be read, so the atrium's daylight is entered as a 40% glazed south wall. Rammed earth is entered as lime.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for a campus. Material and view are strong everywhere; sound is weak everywhere.

WHAT THE READING FOUNDThree things about an orchid made of earth and timber

16 of 16buildings on this page lit partly
by a rooflight the tool cannot see
the rooflight again

The centre of the building is a rooflight.

The solar chimney and its oculus are both the building's light and its ventilation. The light model reads windows in walls, so the atrium's daylight is a stand-in, a south wall glazed at 40%, and the December dose of 0.58 describes the stand-in.

That makes six buildings on this page, of sixteen, lit partly by something the light model cannot see. It remains the largest single thing the tool is missing.

GENERATED FROM solar geometry for 49.24°N on a stand-in wall · dimension 03 · the rooflight case is not in the tool
24.07sreverberation, the atrium, eighty people
target 0.6–0.9 s · sound 0
natural and hard

Earth and timber are good to touch and hard to sound.

Material 85 and view 93 in the atrium: the eye meets earth, timber and garden. Sound comes back 0 at 4.07 seconds, because rammed earth, glulam and concrete reflect nearly everything. The finishes that make a building read as natural are, acoustically, the same as concrete.

It looks like a trade-off between two of the studio's own pillars, biophilic material and a room people can talk in, and the second drawing tests it. Of twenty-five wall and ceiling combinations, the ones that fix the sound all change the ceiling. Keep the earth walls, make the timber ceiling slatted instead of solid, and reverberation falls from 4.07 to 1.36 seconds while the material reading moves by one point. The conflict is real, and it is one surface wide.

GENERATED FROM Sabine T60 on the stated finishes · raycast census · dimensions 02 and 07
30 of 6models that read energy, water or carbon
the building's main claims
the sustainable pillar

Net zero energy, rainwater, treated blackwater: a kind of performance read by other tools.

Like CopenHill, this building is known for systems the six models do not read. Its geothermal boreholes, photovoltaics, solar hot water and water treatment are invisible in every number above.

Two buildings on this page are now famous mainly for sustainable design, and the tool has nothing to say about either. That is the thinnest pillar, stated twice.

GENERATED FROM the six models as they stand · see the Pillars page · no energy or water model yet

WHAT I WOULD CHANGEA timber ceiling in the café, and absorption in the atrium

The sweep proposes 6500 K lamps everywhere, textile walls in the atrium and the library, and a slatted ceiling in the café.

ZoneWhat the sweep proposesNowAfter
Atrium under the oculus6500 K lamps · textile walls6584
Café6500 K lamps · slatted ceiling7792
Library6500 K lamps · heavy planting · textile walls5276

The slatted ceiling in the café is the one to take: it is timber, it fits the room, and it answers the sound. The textile walls would cover the rammed earth, which is the point of the building, so absorption in the atrium would have to come from the ceiling. The lamps stay at 3000 K.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. The rooms are scaled from photographs.
  • The oculus, finding 1.
  • Rammed earth is read as lime. Its real absorption is not in the tool.
  • Energy, water and carbon, finding 3.

What it can show is the most useful conflict on this page: a building whose natural materials are exactly what make it loud. That is a question for the next thread, not a criticism of the building.

09 · INDEPENDENT STUDYShanghai Tower

A 632 m tower in two skins of glass. Its ordinary office floor is its best room; the sky garden between the skins echoes for fifteen seconds.

Gensler2015 · MARSHALL STRABALA, JUN XIA
Lujiazui, Shanghai · 31.23°NCHINA · OBSERVATION FLOORS OPEN
OfficeBUILDING TYPE · SETS THE WEIGHTS
Built632 M · 128 FLOORS ABOVE GROUND
4 zonesAN OFFICE, A SKY GARDEN, THE TOP, A LOBBY

Open the tower in the reading tool →Loads the four zones as read here. Every zone is "high" to the tool, at any height; finding 3. · See the building → · Wikipedia →

The tower above the Lujiazui skyline, its twisting outer skinimages/research-shanghai-tower.jpg · 1920 × 1080Credit: Stefan Fussan, CC BY-SA 3.0
Photograph: Stefan Fussan, CC BY-SA 3.0, via Wikimedia Commons
The twisting outer skin. Behind it, in the gap between the two skins, sit nine garden atria; this reading is about one of them.

What the numbers stand on

The tower is published in round figures. The rooms inside it are not, so every zone is scaled.

KNOWN · PUBLISHED

  • Completed 2014 and opened 2015; 632 m, 128 floors above ground and 5 below; about 380,000 m² above ground
  • Nine stacked zones, each with an atrium of gardens, cafés and shops between an inner and an outer glass skin
  • The outer skin twists 120° as it rises, which the designers report reduced wind loads by 24%
  • Shuttle lifts to the observation floors at 20.5 m/s

SCALED · AND ONE THING TAKEN FROM PRACTICE

  • An office bay as 40 × 12 × 3.2 m, core to glass, a hundred people
  • A sky garden atrium as 30 × 8 × 55 m between the skins, sixty people
  • The observation floor as 40 × 40 × 5 m, three hundred people
  • A lift lobby as 10 × 6 × 4 m with no window, thirty people

MAPPED · AND WHAT THE TOOL LACKS

  • Office: acoustic tile ceiling, carpet, laminate at the hand, white at 4000 K
  • Atrium: glass → concrete for sound, stone floor, steel rail; the gardens → a few plants
  • The view from 500 m → sky
  • Height. The tool has one band for "high". Finding 3

Research card

Study 09 · Read

Problem
A 632 m tower with nine garden atria held between two skins of glass.
Question

Do the spaces designed to be remembered read better than the ordinary ones?

Method and analysis
Method
Four zones, an office floor, a sky garden, the observation deck and a lift lobby, scaled. Horizon distance computed from four heights.
Analysis
Compared: Zone type, finishes, height. Measured: Reverberation, total reading, distance to the horizon.
Finding
The office floor reads 0.46 s and totals 71, the best room in the tower. The sky garden rings for 15.6 s.
Design implication
Ordinary fit-out already solves what these models measure. The signature spaces need the same care, and height needs its own model.

THE ZONESA garden between two skins, and a view eighty kilometres long

The reading takes one room from each kind of space the tower has: where people work, the garden between the skins, the top, and the windowless lobby every journey passes through.

The tower to scale, 632 m or 375 median bodies, with the three corners of the outer skin traced in amber as they twist 120° up the height (front solid, back faint) and the nine zones ticked (their heights are schematic). To the right, the plan at three zones, showing the rotation and that the gap for the gardens is widest at the corners (proportions schematic), and one sky garden at nine times the scale: 55 m of air between two skins of glass, the garden at its foot, and a person, very small. As read, it rings for 15.6 seconds.
How far a window sees, from four heights, with the geometry of a sphere: about 11 km from a street window, 36 km at 100 m, 62 km halfway up, 87 km near the top, where the horizon sits 0.79° below level. Above the first few storeys the reading tool puts all of these windows in the same floor band. Heights and the earth's curve are not drawn to scale.

Zone schedule, as read

ZoneUseW × D × HGlazingCeiling · Walls · FloorTouchedColour · Light
Office floorFocus40 × 12 × 3.2east, 90% · builttile · plaster · carpetlaminatewhite · 4000 K
Sky garden atriumGather30 × 8 × 55south, 95% · skyconcrete · concrete · stonesteelwhite · 4000 K
Observation deckGather40 × 40 × 5south, 95% · skyplaster · plaster · stonesteelwhite · 4000 K
Lift lobbyMove through10 × 6 × 4noneplaster · concrete · stonesteelgrey · 4000 K

All four zones are entered at the tool's highest floor band, which it uses for anything above a few storeys.

THE READINGZone by zone, as the tool gives it

Six models per zone, weighted for an office. The office floor reads best, and the sky garden, the tower's signature, reads worst on sound.

WHAT THE READING FOUNDThree things about a tower in two skins

10.46sreverberation, the office floor
target 0.4–0.6 s · sound 100
the ordinary room wins

The most ordinary room in the tower reads best, and that is the finding.

An acoustic tile ceiling, carpet and a hundred people give 0.46 seconds, inside the band for focused work, and a sound score of 100. The office floor totals 71, the best zone in the tower. Nothing about it is unusual, which is the finding.

Commercial office fit-out has spent decades solving exactly the problems these models measure. The rooms that read worst on this page are the ones designed to be remembered.

GENERATED FROM Sabine T60 on the stated finishes · dimension 02
215.6sreverberation, the sky garden atrium
read as a glass slot 55 m tall
the garden, heard

The gardens that justify the double skin read as a hard shaft.

Between two skins of glass, fifty-five metres tall, the atrium rings for 15.6 seconds. The planting counts toward the view and not toward the sound, the same gap Jewel exposed at a much larger scale.

The atria are where the tower is meant to feel human. As read, they are the loudest rooms in it.

GENERATED FROM Sabine T60 on the scaled volume · planting counted in view only · dimensions 02 and 07
3"high"the tool's floor band for every zone
from a fifth floor to the top
height is one number

At the top of the tower, light reads like any high floor; height itself is the next thing to model.

The floor band sets how much sky a window sees, and "high" is the highest band there is. It is right for the light. It says nothing of what five hundred metres does to a body: sway, pressure in the ears, the edge.

None of those is in any of the six models, and neither is the view itself: from near the top the horizon is about 87 km away, eight times as far as from a street window, and the tool reads it as sky, the same as any rooftop. For almost every building the studio will be asked to read, they will not need to be. For this one they are part of the experience, and the reading is honest only if it says so.

GENERATED FROM the floor bands as they stand · dimension 03 · no altitude effects in the tool

WHAT I WOULD CHANGEPlanting in the lobbies, and a ceiling at the top

The sweep proposes warm lamps, heavy planting and wool at the hand everywhere, textile walls in the atrium, a slatted ceiling on the observation floor and carpet in the lobby.

ZoneWhat the sweep proposesNowAfter
Office floor2700 K lamps · heavy planting · wool at the hand7181
Sky garden atrium2700 K lamps · heavy planting · wool at the hand · textile walls5678
Observation deck2700 K lamps · heavy planting · wool at the hand · slatted ceiling5382
Lift lobby2700 K lamps · heavy planting · wool at the hand · carpet4160

Planting and warmer light in the windowless lobbies and an absorbent ceiling over the observation floor are ordinary, reversible moves. Textile walls in the atrium are not: the atrium is glass on both sides. Wool at the hand is refused, as in every busy building on this page.

THE LIMITSWhere this reading stops, and what comes next

  • The studio has not been inside it. Every zone is scaled.
  • Height, finding 3.
  • The double skin's climate. The atria are buffers between inside and out, and there is no thermal model.
  • The view. From five hundred metres the tool sees sky; the city below is not in the view model.

What it can show is a tower whose ordinary floors are good rooms and whose special spaces are hard ones. That is the opposite of how towers are usually photographed, and it is the kind of thing a reading is for.

The demonstration →Read your own roomBring a building