PercepxiON · Studies
Sixteen real public buildings, read from their published plans with the studio's own tools. Each was chosen because it was never designed to pass the method, which makes it the fairest test of where the method holds.
Why read them
A model tested only on its own clients agrees with itself. Buildings that were never designed to pass it show where it holds and where it breaks.
Scroll
Open the reading →A basilica built around coloured light. Read side by side, its two halves differ in winter sun, not in colour: the warm side keeps its daylight, the cool side barely gets enough.
Open the basilica in the reading tool →Loads the four zones as read here. The colour reading will not move; finding 1 is why. · See the building → · Wikipedia →
images/research-sagrada-vault.jpg · 1920 × 1080Credit: Julian Lupyan, CC0The geometry is published to the metre and the glass is published as a scheme, not as a spectrum, which is the gap finding 1 sits in.
Research card
Study 01 · Read
The reading splits the nave down its axis so that each half faces one glass. Everything else about the two halves is identical: same stone, same floor, same height, same pews, same crowd. Any difference the tool returns between them is a difference the glass made, and that is the experiment. The section is drawn to scale across the nave; the plan is schematic, turned so that it reads the same way round.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Nave, Nativity side | Gather | 22.5 × 45 × 45 | north-east, read as east, 45% · city | stone vault · stone · stone | oak pew | cream · 3000 K |
| Nave, Passion side | Gather | 22.5 × 45 × 45 | south-west, read as west, 45% · city | stone vault · stone · stone | oak pew | cream · 3000 K |
| The crossing | Gather | 45 × 30 × 60 | south, 25% · sky | stone vault · stone · stone | oak pew | cream · 3000 K |
| Gaudí's crypt | Rest | 25 × 25 × 9 | south, 10% · blank | stone vault · stone · stone | oak pew | beige · 2700 K |
Heights are taken at the crown, which the Kimbell reading shows to be the wrong line for a body. Sagrada Família has the same two-height problem at nine times the size. The Eixample grid sits about 45° off north, so the aisle walls face north-east and south-west, exactly between two of the tool's four cardinals; finding 4 reads them both ways.
Six models per zone, weighted for worship. The two nave halves come back identical on five of six, and the one that moves is not the one you would expect.
Vila-Grau's glass is cool on the east and warm on the west, and every visitor who has walked from one side to the other in an afternoon can tell you the two halves are different rooms. The tool returns 44 for both. It is not a rounding. The colour model multiplies a wall pigment by a lamp temperature, which is the right arithmetic for a painted room under a bulb, and this building colours the light before it reaches any pigment at all. The term does not exist to be wrong.
This is the most useful result in the set, because it is specific enough to build. A seventh input, the spectrum of the light arriving rather than the temperature of the lamp emitting, would read stained glass, coloured film, a green courtyard and a red brick lightwell with the same model. Until it exists, the studio's rule is to say so on the face of the reading rather than publish 44 as though it meant something.
Sabine on 45,600 m³ of stone gives ten and a half seconds for each half of the nave; the crossing, read as a 60 m box, gives seventeen. The real figures should sit lower, for three reasons that all run the same way: the hyperboloid vaults scatter where a box reflects, the columns break the field, and the tool counts the crowd only as bodies in a number rather than as the largest absorber in the room. So the figure is an upper bound and is labelled one.
What the number does say honestly is the shape of the problem. A basilica is the one building type where a very long reverberation is part of the brief for one use, singing, and fatal to another, speech, and the tool has a single target for both. That is the second specification this building writes.
Forty-five metres is 26.7 median bodies stacked; the crossing is 35.6. Both come back 72, scored as a hall with an abstract prime. So does the Kimbell vault, at 3.6 bodies. The scale model stops distinguishing somewhere around four and returns the same figure for a gallery vault, a cathedral nave and a crossing eight storeys taller than the nave.
That is defensible as far as it goes, since the research the model rests on measured rooms, not cathedrals, and refusing to extrapolate is the honest move. It is worth saying out loud rather than leaving in the number: 72 here does not mean the crossing is as generous as a museum vault, it means the model declined to have an opinion and said so in the only vocabulary it has.
The Eixample grid runs about 45° off north, so the nave's side walls face north-east and south-west, exactly on the boundary between two of the tool's four cardinals. Its own notes say to read a wall like that both ways, and this is what comes back for December, averaged across the working day: the Passion side reaches 0.42 read as west and 0.63 read as south, clear of the 0.30 a body needs either way. The Nativity side reaches 0.32 read as east and 0.17 read as north. That is the difference between just clearing the threshold and the same winter shortfall the demonstration library has.
So the honest reading is that the cool side is marginal and the warm side is not, and the gap between them is the sun, not the glass. South-west takes the afternoon, and in December the afternoon carries the dose. The one measurable difference the tool found between the two sides of the nave has nothing to do with the colour everyone comes for.
The crypt is nine metres high rather than forty-five, and it comes back 35, the lowest of the four. Scale 0 at a ratio of 5.34, sound 10.34 s in a room a tenth the volume of half the nave, view 19 because there is almost nothing to see out of. Every zone above it scores 55 on the strength of a daylight dose and a scale reading that the model admits it cannot resolve.
Read that as a warning about ranking rather than about the crypt. Three of the four zones share a total to within a point because two of their six readings are pinned at their ceilings and two are pinned at zero. When half a reading is at a limit, the total stops being a comparison and becomes an artefact, and this building produces that artefact four times.
Run the sweep and it proposes 6500 K lamps, heavy planting and textile walls, for a gain of fourteen points. In a UNESCO basilica under a continuing works programme those are not moves, they would harm the building, and the studio refuses them in the same terms it refuses the Kimbell's. The table is printed anyway, because a reading that only shows the moves it likes is not a reading.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Nave, either side | 6500 K lamps · heavy planting · textile walls | 55 | 67 |
| The crossing | 6500 K lamps · heavy planting | 55 | 61 |
| Gaudí's crypt | 6500 K · planting · slatted ceiling · textile walls | 35 | 58 |
Refused, all of it. The one move worth even a conversation is the crypt's lamp temperature, which is reversible and invisible by day, and the studio would want to stand in the room at dusk before saying so. Everything the sweep offers above the crypt line is a generic move, and a protected basilica is exactly where a reading has to know when to stop.
What it can show is what an instrument does when it meets a building outside its range. It does not fail loudly, it returns a plausible number. Four of these six models returned plausible numbers about the wrong thing, and the only reason you can tell is that the two nave halves came back identical when everyone who has stood in them knows they are not.
The quietest-looking building in modern architecture. It scores well on light and scale, badly on sound, and the sound problem turns out to be about a curtain.
Open the pavilion in the reading tool →Loads the four zones exactly as read here. Draw the curtain yourself. · See the building →
A real building read from published sources is only as honest as its inputs, so they are sorted here before anything is computed.
Research card
Study 16 · Read
Redrawn from the published plan on the 1.1 m module. The building has no rooms, only planes, so the plan is read the way a visitor reads it: by what is in sight. From any point on the route, 720 sightlines are cast against the stone and the onyx; glass is seen through. Zones are the rectangles the reading tool needs.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Onyx hall | Gather | 12 × 8 × 3.1 | east, 85%, ground | plaster · polished marble · travertine | chrome, glass | golden onyx · daylight |
| Green room | Gather | 8 × 6 × 3.1 | west to the court, 70% | plaster · Tinos marble · travertine | chrome, glass | deep green · daylight |
| Glass passage | Move through | 3 × 12 × 3.1 | east, 85% | plaster · marble · travertine | chrome, glass | travertine · daylight |
| Annex | Focus | 4 × 8 × 3.1 | west, 30% · a wall | plaster · plaster · travertine | steel | white · 4000 K |
Occupancy for the acoustic reading: twelve in the hall, six in the green room, four in the passage, two in the annex, a quiet afternoon. Empty figures are given where they matter.
Six models per zone, weighted for a gallery. The ring is the overall; the bars are light across the year, sound, scale, material, colour under light, and view.
Three readings the tool cannot give, wayfinding, circulation rhythm, the emotional map, are taken from the plan by hand in finding 5, and said to be.
Every surface in the hall is polished stone, glass or chrome; the plaster ceiling is the softest thing in it. Sabine's formula on 298 m³ with fourteen square metres of absorption, most of it people, gives five seconds of tail on every footstep and a clarity index of 8, the one number on this page most visitors would confirm from memory.
Then the curtain. Lilly Reich's red velvet along the east glass is 37 m² of the only absorbent material in the building; drawn, it takes the occupied room to 1.58 s. The black carpet recorded in 1929 takes it to 1.17 s on its own. Together they give 0.84 s, inside the band for a room people gather in. In 1929, with the King in it, the room was acoustically right. What the reconstruction shows with the curtain open is the photograph.
Mies took the height from the stone: one block, split twice, stacked. 3.1 m is above the body-scaled comfortable ratio for every stature in the population sweep, the tallest adult in the model has 1.1 m of air over the head, and it sits at the ratio the ceiling studies associate with abstract rather than concrete thinking. For a room built for a ceremony and now used for looking, that is the right prime, and the model says so without help.
The one place it argues is the annex: the same 3.1 m over a 4 m wide room for focused work reads as a mismatch, because a small room wants a lower sky. Nobody photographs the annex; that is where the mismatch is.
Everything the hand can meet in the pavilion is chrome or glass: the columns, the door, the Barcelona chair's frame. On the skin-response integral those are the coldest contacts in the tool, and because the hand returns to them far more often than the eye rests on any one wall, they carry two-thirds of the modelled cost, the same contact-frequency finding as dimension 07, on a building that has no handrail because it needs none.
The eye does no better than 46 on the restorative scale: the surround is polished stone on every side, and the view is the pool and the travertine wall, no plant, no tree, no sky to speak of. The most evidenced move in the whole literature, greenery in the sightline, is structurally absent. The pavilion replaces it with water, and no model here has a term for water. That is in the limits.
Both are lit by the same daylight. The onyx is warm under cool light, a true mismatch, which both colour studies found to be the comfortable corner. The Tinos marble is cool under cool light, a matched pairing, which they found raises tension. Same ceiling, same floor, same glass; the wall colour alone moves the reading by thirteen points, and against the intuition that the green room, facing the court and the sculpture, is the restful one.
This is a prediction, not a measurement. It is exactly the kind of prediction the pilot protocol exists to test, and finding 5 says where.
Wayfinding. There are no signs and there is no need for one. Every freestanding plane is placed so that the next destination is partly visible past its edge, the onyx shows the court opening, the glass shows the pool, which is Lynch's edge and landmark doing the entire job. The one decision the plan makes hard is the branch behind the onyx: from the door, the green room does not exist. Read from the plan; the dimension 08 tool is built around its own hospital plan and was not run here.
Circulation. Three right-angle turns between the steps and the court, none of them a corridor. The corridor study measured the pace drop at exactly this angle. A pavilion that makes you turn every fifteen metres is a pavilion that makes you walk slowly, which is what it was for.
The emotional map. Nobody has walked this building with sensors on, and the studio proposes to. It is open to the public, small enough for the dimension 01 protocol's eight zones, and the reading above makes two testable predictions: the sharpest settle at the door when the curtain is drawn, and the green room reading tenser than the gold one. The route and zones are the ones drawn here.
It is a monument; the finishes are the point. The two reversible moves it already owns take the hall from 61 to 77 for a gallery weighting, and cost a curtain-pull and a carpet. Everything else the tool would suggest, timber, textile, planting, would be a different building.
| Zone | Move | Now | After |
|---|---|---|---|
| Onyx hall | Curtain drawn, carpet laid, as 1929 | 61 | 77 |
| Green room | Left as built · the carpet does not reach it | 58 | 58 |
| Glass passage | Curtain drawn along its length | 62 | 72 |
| Annex | Left as built | 54 | 54 |
The passage figure is the hall's method on the passage's volume: 37 m² of velvet is most of its east wall too. The green room is behind the onyx and gets none of either, which is why the tense room stays the tense room.
What it can show is the method holding on a building it was not designed for: every published fact used, every scaled one labelled, and one finding, the curtain, that the plans contain and the photographs hide.
A library that is also a passage, from the street to a garden, with glass reading rooms bridged above it. Each room feels different depending on which glass wall you sit by.
Open the library in the reading tool →Loads the four zones as read here. Change the ceiling and see finding 2 settle. · See the building →
Less is published about this building than about the pavilion, and the reading says so. The finishes inside the boxes are the weakest input; finding 2 is built around that.
Research card
Study 05 · Read
The building's argument is that every reading room has the street on one glass wall and the garden on the other. The two drawings test what that means for light: the year's sun on each face, and the winter sun at the street glass once the building across the street is in the way.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| The door (ground) | Move through | 8 × 20 × 5.5 | open both ends · garden | steel · steel · stone | steel | charcoal · 4000 K |
| Reading box, garden side | Focus | 14 × 8 × 3.0 | north, 50% through slats · trees | plaster · plaster · resin | steel | white · 4000 K |
| Reading box, street side | Focus | 14 × 8 × 3.0 | south, 50% through slats · street | plaster · plaster · resin | steel | white · 4000 K |
| Children's box (top) | Create | 14 × 8 × 3.0 | north, 50% · trees, upper floor | plaster · plaster · resin | laminate | white · 4000 K |
The garden-side and street-side readings are the same box, read from a desk at each glass wall, the tool reads one window at a time, so a room with two is read twice and said to be. Occupancy: six passing through, twenty-four in a box, twenty children.
Six models per zone, weighted for a library. Sound is read with the hard white ceiling the photographs show; finding 2 reads it again with an absorbent one.
One box, two glass walls, and they do not agree. Facing the garden, a reader has trees filling the sightline, the strongest restorative factor in the literature, and the view reads 80. Facing the street, the reading drops to 34. But the garden face looks north through steel slats, and from October to March the desk there gets 0.23 of a circadian dose against a threshold of 0.30. The street face, south-west through the same slats, gets 0.63. The room that restores the eye under-doses the body clock; the room that doses the clock has nothing to look at.
Without the slats the garden desk would read 0.32, just over the line. The screen that makes the façade is the thing that takes the north desks under it, if it wraps the garden face as the photographs suggest. That is a question for the visit, and the cheapest answer is to put the long-stay desks on the street side in winter and the garden side in summer.
A 14 × 8 × 3 m box with glass on two long sides, plaster on the rest and a resin floor holds 2.3 s of reverberation with twenty-four people in it, a reading room where every chair scrape lasts. Swap the ceiling for an absorbent one and the same box reads 0.55 s, inside the band. Nothing else in the room changes; the sound reading goes from 0 to 100 and the box from 56 to 78.
The sources do not say which ceiling it has. A library completed in 2007 would normally have the absorbent one, and the photographs are ambiguous. So the reading declines to pick: the two states are both on this page, and the first thing the studio does on site is look up.
Three metres over a 14 m wide floor is comfortable for every stature in the sweep, and it primes abstract thinking. For the children's floor, where the use is to make and imagine, the model calls that a good fit and scores 100. For the adult reading floors, where the use is to focus, it calls it a mismatch and takes fifteen points: focused work wants the lower, concrete sky. RCR built one section and stacked it three times, and the model can tell which floor the section was drawn for.
Nothing can be done about it in a built building, and nothing should be. It is worth knowing which floor to put the exam revision on.
Eight by twenty by five and a half metres of dark steel and stone: read as a closed room, Sabine gives nine seconds, a number no passage has ever had. The door is open at both ends to the street and the garden, and an opening is a perfect absorber, 88 m² of it. Put that in by hand and the passage reads 1.43 s, at the edge of the band for a space people move through and not far off what a covered street sounds like. The tool scores it 0 because it cannot see an opening; the honest figure is a pass.
This is the second thing a real building has taught the tool. The pavilion taught it about halls; this one teaches it that a room with no wall on one side is not a room, and the reading tool will grow an "open end" the next time it is revised.
Wayfinding. From the pavement you see the garden through the building; the door is the sign, and Lynch would call the whole library a node. The decision the plan hides is the one that matters to a library user: where the stair is. It sits in a side volume, off the passage, and the passage gives no view of it, one sign at the passage's mid-point, at the height of a walking eye, is the only one the building needs. Read from the plan; the dimension 08 tool was not run here.
Circulation. Two rhythms in one building. The through-route is a straight 20 m, no turns, the pace of a street. The up-route is a stair in a box and then, between the last two floors, a run of steps inside the reading room itself, which the corridor study would predict slows people at exactly the point the library wants them slowed.
The emotional map. The garden is shared by the children's play area and the senior centre, and the reading rooms look down on both. The pilot protocol's route here would run street → door → garden → stair → box, and the prediction on record is the largest settle at the garden threshold, not in any reading room.
A built library at refurbishment stage: finishes and furniture. The ceiling is the large move if it is needed; the tables are the small one; where the desks go is free.
| Zone | Move | Now | After |
|---|---|---|---|
| Reading box, garden side | Slatted timber ceiling · timber floor · oak tables | 56 | 87 |
| Reading box, street side | The same · magazines and short stays here | 51 | 83 |
| Children's box | Absorbent ceiling if absent · oak on the tables | 63 | 87 |
| The door | Left as built, it is the building | 56* | 56* |
* The door's figure carries the tool's sound score of 0; with the hand-corrected 1.43 s it would read in the seventies. It is shown as the tool gave it, because the correction is not in the tool yet. The garden-side figure of 87 assumes the hard ceiling was there to replace; if the box already has an absorbent one, the tables alone take it from 78 to 82.
What it can show is a reading that names its own weakest input instead of hiding it, gives the answer under both states, and turns a visit into a two-minute check: look up, and look at the slats.
Sixteen concrete vaults lit by hidden slits of sky. Its famous light is, by design, too dim for the body clock, and the building changes mood at dusk.
Open the museum in the reading tool →Loads the four zones as read here. The tool has no skylight; finding 1 corrects it by hand. · See the building → · Wikipedia →
images/research-kimbell-galleries.jpg · 1920 × 1080Credit: Andreas Praefcke, public domainThe vault is published to the foot; the light is published as a quality, not a quantity, and that gap is what finding 1 is about.
Research card
Study 10 · Read
The whole building is one drawing repeated: a 6.1 m span on 3.05 m walls, rising to 6.1 m at the crown, with the light coming in where the vault should be strongest and turned back onto it. The section is drawn below with the path the light takes; the plan is schematic, to show the rows, the courtyards and the one route the reading uses, in at the west, along a vault, past a courtyard.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Gallery vault, interior | Gather | 6.1 × 30.5 × 6.1 | rooflight only · no window | concrete · travertine · white oak | steel rail | travertine · daylight |
| Gallery vault at a courtyard | Gather | 6.1 × 30.5 × 6.1 | north end, 50% · courtyard trees | concrete · travertine · white oak | steel rail | travertine · daylight |
| Entrance vault | Move through | 6.1 × 30.5 × 6.1 | west, 80% · portico and trees | concrete · travertine · travertine | steel rail | travertine · daylight |
| Auditorium | Gather | 6.1 × 30.5 × 6.1 | none | concrete · travertine · carpet | steel rail | travertine · 3000 K |
The interior vault is read with no window, which is what the tool sees; its light is then corrected by hand. The vault's height is taken at the crown; its volume is a box, about 20% over the true cycloid.
Six models per zone, weighted for a gallery. The interior vault's light reads 0 because the tool cannot see a rooflight; finding 1 gives the real figure, which is not much better, for a reason.
Twenty-three square metres of sky per vault would light a room hard; the reflector takes almost all of it and gives back a glow off the concrete that sits, at the eye, in the range paintings can tolerate, 150 to 300 lux. On the circadian model that is a dose of 0.15 to 0.26, under the 0.30 a body needs, in a building people rightly call the best-lit room they have stood in. The two claims do not conflict. The light is beautiful because it is dim and even; it is dim and even because oil paint fades.
The tool scores the gallery 0 for light because it has no rooflight; corrected, it would score about 60. Both numbers would be wrong to act on. A gallery is the one room type where the visitor's dose is the wrong target, and the reading tool should say so rather than score it, which is a change to make.
Travertine is warm. Under the sky's light, cool, silver, the thing everyone describes, warm stone under cool light is the true mismatch, which both colour studies found to be the comfortable corner: negative affect 36, colour reads 66. At dusk the reflectors go dark and the lamps come on, and in 1972 lamps were warm. Warm stone under warm light is the matched pairing that tests badly: 56, colour reads 45. The building most admired for its daylight has, on this model, a different temperament after it.
The lamp is the fix, as on every page here: cool white after dark keeps the mismatch and takes the evening room back to 56 on the colour reading. Whether the Kimbell has already made that move in a relamping is a thing to check; the model predicts the evening visitor would feel it.
Sabine on 1,135 m³ of concrete, travertine and oak gives four seconds; open six vaults into one suite and the volume grows faster than the absorption and it reads six and a half. That is the tool's reading and it is an upper bound: it counts no paintings, no partitions, no benches, and a gallery has all three. What it does say honestly is that the finishes do nothing for the ear, and that the hush people report in the Kimbell is people, art and manners, not the room.
Nothing here should change, the finishes are the building, and the tool's fit-out moves are all refused on a listed interior. The reading is recorded to be tested with a clap on site, which is a five-second experiment.
The tool takes one height and reads the crown: 3.6 bodies, a hall, abstract prime, scored as generous. But the eye does not rest on the crown of a cycloid; it rests where the wall stops and the curve begins, at 3.05 m, 1.81 of the median body, just above the comfortable ratio and inside the range where a ceiling is still measured against oneself. Kahn put the human height at the springing and the sky above it. The reading tool has no term for a room with two heights, and this is the building that shows why it should: the 3 m line is the one the body uses, and the 6 m one is the one the light uses.
Wayfinding. Sixteen vaults of the same section, the same finish and the same light are, in Lynch's terms, a plan with no differentiation: every room is the room you just left. What saves it is the three courtyards, glass-walled, planted, the only places the sky comes in sideways, which are the building's landmarks and the reason a visitor can say where they are. The route the reading takes is along one vault and past one courtyard because that is the route the plan gives a memory to. Read from the plan; the dimension 08 tool was not run here.
Circulation. Vaults run north–south, so the building's pace is set by a 30 m straight with the light overhead and a turn at each end. Dimension 04 would predict an even walking rhythm, no corridor, no forced turn, and a slowing wherever a courtyard opens the wall.
The emotional map. The prediction on record: the settle points are the courtyard vaults, not the famous interior ones, view 80 against 18 is the largest gap in the whole reading, and the sharpest change in the building is at dusk, finding 2.
Lamps and rails. Everything else the tool suggests, absorbent ceilings, textile, carpet, would harm the building here, and the reading refuses it. The two moves below are reversible and cost nothing the building would notice.
| Zone | Move | Now | After |
|---|---|---|---|
| Gallery vault, evening | Cool white lamps after dark (5000 K) | 38 | 41 |
| Gallery vault | Oak on the handrails | 41 | 44 |
| Courtyard vault | Oak on the handrails | 58 | 62 |
| Entrance vault | Oak on the handrails | 61 | 64 |
Small numbers, on purpose. The building's readings are held down by two things the studio would not touch, the light level, which is for the art, and the finishes, which are the architecture, and the tool is being asked what is left. The evening figure is the gallery read under 2700 K lamps; 4000 K would give the same 41.
What it can show is a building that fails two of the tool's tests deliberately and for good reasons, which is the most useful kind of result a reading can return: not a score, but which of its own targets do not apply.
Five stacked, shifted floors, and a well-known place to get lost: in 2019, 59 people were tracked through it. The plan shows why.
Open the library in the reading tool →Loads the four zones as read here. Two of them need a correction by hand, and finding 3 shows it. · See the building → · Wikipedia →
The building is unusually well published and unusually well studied; the studio has read the plans and the wayfinding study, not walked the floor. That is said here and again at the end.
Research card
Study 11 · Read
OMA explained the building with one diagram: five solid platforms, each a programme that is stable, parking, staff, assembly, books, headquarters, shifted against each other, and the loose spaces the shifts leave between them for the programmes that change: the Living Room, the Mixing Chamber, the Reading Room. The section below keeps that idiom and adds the one thing the diagram never showed: how you get from one to the next. Escalators are on the sides the participants reported, alternating, and there is no escalator down. Dots mark each arrival where the next link is out of sight.
images/research-seattle-exterior.jpg · 1920 × 1080Drawn by the studio. Mark the three arrivals where the next link is out of sight, and that nothing goes down.| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Living Room (L3) | Gather | 60 × 40 × 12 | east, 50% through mesh · city | platform underside · glass, concrete · carpet | steel | pale grey · 4000 K |
| Mixing Chamber (L5) | Focus | 60 × 40 × 3.5 | west, 30% · city | exposed · concrete · carpet | laminate | charcoal · 4000 K |
| Books Spiral (one level of 6–9) | Move through | 60 × 40 × 3.0 | east, 40% · city | exposed · shelving · rubber | steel | pale grey · 4000 K |
| Reading Room (L10) | Focus | 40 × 30 × 9 | east, 60% · sky through mesh, upper floor | glass roof · concrete · carpet | laminate | white · 4000 K |
Occupancy for the acoustic reading: 120 in the Living Room, 200 at the computers, 60 browsing a Spiral level, 200 of the 400 seats taken.
Six models per zone, weighted for a library. Two of the twenty-four bars below are shown as the tool first produced them and corrected in findings 3 and 4; both stay visible, because that is what testing a tool on a real building is for.
The dimension 08 tool's finding on its hospital plan was that a sign only works inside a line of sight, that two well-placed signs beat seven, and that past a point more signs make people worse. Seattle is the same finding at building scale. Each platform is shifted in plan, so the escalator that brought you to a floor and the one that takes you off it are on different sides, the participants' word was "random", and from three of the four arrivals on the route up, the next link is not inside any isovist. Bruce Mau's floor-scale lettering solves the within-floor task, and the study found within-floor tasks easy. Nothing on a wall solves between-floor, and the study found between-floor hard.
Then down. There is no down escalator. The stairs are, in the participants' words, not always visible, so the strategy that got a visitor up cannot be run in reverse; every descent is a new wayfinding task. This is the one reading on the page that was checked against people before the studio made it, and the people had already made it.
Three rises of 3.7 m at a maximum slope of 2° is at least 318 m of floor, more, wherever the slope eases, to get from level 6 to level 9 by the route the shelving takes. At 1.3 m/s that is four minutes; at the 0.7 m/s people browse at, nearly eight. Dimension 04's corridor study found pace drops at right-angle turns and recovers on straights; the Spiral has no right angles at all, which is why it reads as effortless to walk and why, per the study, going up felt easy. What it does not have is a short way. A reader who wants the 900s from the 100s walks the building.
The 2° also does a quieter thing: it takes the floor out of the body's reference. On a ramp that shallow the eye cannot see the slope and the legs can feel it, and the study's adjectives, overwhelming, stressful, sit alongside impressive and stimulating in exactly the proportion a sustained low-grade arousal would produce. That is a prediction for the pilot, not a finding.
Read as a 60 × 40 × 3 m plate of exposed concrete, steel shelving and rubber floor, Sabine gives seven seconds, a car park. But a Spiral level is rows of open shelving every metre and a half, two metres high, both faces lined with paper, and a book face absorbs about a third of what reaches it. Twenty-six rows of 60 m shelving is 6,240 m² of book face, which is 2,300 m² of absorption in a room whose surfaces supply 160. Put the books in by hand and the level reads 0.49 s, just under the 0.6 to 1.3 s band for a space people move through, a score of 92 where the tool gave 0. The library is quiet because it is full of books; the tool did not know what a library was.
The pavilion taught the tool about halls, Sant Antoni about open ends, and this one about contents. Shelving goes into the reading tool next, as a wall type with an absorption and a surround value of its own.
The Mixing Chamber and the Spiral score 0 for scale, and that is the visual-angle term: over a 40 m plate, a 3 m ceiling subtends under 6° at the far wall and the model calls it oppressive for every stature. The feeling is real, a low ceiling over a deep floor is the big-box feeling, but the model's threshold sits exactly on the value it produces, so 0 is a cliff, not a reading. It will be softened in the next revision and it is reported here as it fell.
The Reading Room's 0 is a different thing: an opinion. Nine metres of glass over a room for focused reading is 5.5 bodies of air, the cathedral prime, and the ceiling studies associate it with abstract rather than concentrated thought. The demonstration taught the tool to stop punishing halls for gathering; it still punishes them for focus, on purpose. Whether 400 readers under a glass sky concentrate less is a testable question and one of the better ones the pilot could ask.
At 47.6°N under a diagrid mesh that halves the light, the Living Room reaches the threshold in the worst month and the Reading Room clears it. That is what a glass building is for and the model gives both rooms nearly full marks. The reading assumes a position near the glass; the plates are 40 m deep, and the model has already admitted, on the demonstration, that it reads deep plans too kindly. The Mixing Chamber, read from its west edge, holds 0.34; at a computer in the middle of 338 it will not.
The emotional map, by hand: the study's own adjectives. Impressive, creative, stimulating; inconsistent, overwhelming, frustrating, intimidating, stressful. Those are two ends of one arousal scale, and the prediction on record is that the Living Room and the top of the Spiral give the first set and the arrivals in finding 1 give the second.
The building's largest finding is not fixable: a shifted-platform section decides its wayfinding at concept stage, and no later stage can add a line of sight. That is the argument for reading at concept, made by a building that was not. What fit-out can reach is below.
| Zone | Move | Now | After |
|---|---|---|---|
| Living Room | Absorbent platform underside · oak rails · planting | 49 | 67 |
| Reading Room | 2700 K lamps · oak tables · planting · absorbent soffits | 39 | 59 |
| Mixing Chamber | 2700 K · absorbent ceiling · oak desks · planting | 44 | 65 |
| Books Spiral | Left as built · the books already did it | 33* | 33* |
* The Spiral's figure carries the tool's sound score of 0 and scale score of 0; with the books in by hand and the scale cliff softened it reads in the sixties. Shown as the tool gave it. The lamp move on both work floors is the same one as the demonstration's: white walls under 4000 K are a matched pairing; 2700 K turns it into the comfortable mismatch for the price of a bulb.
What it can show is the one thing this page is for: the reading's biggest finding was made by fifty-nine people before the studio made it, from a section alone, which is the case for making it from the section before the building exists.
A building made of water, stone and warmth, read by tools that measure neither water nor warmth. It scores 44.3, which shows a reading is six questions, not a verdict.
Open the baths in the reading tool →Loads the four zones as read here. The tool believes the pools are empty and the room is at office temperature. · Wikipedia →
images/research-vals-terrace.jpg · 1920 × 1080Credit: Felipe Camus, CC BY 2.0The stone is published in millimetres and the water in degrees, and the tool has a model for one of those.
Research card
Study 12 · Read
Vals is a route before it is a set of rooms: you arrive through a dark passage, meet the large hall, and find the small baths off it. The tool reads rooms, one at a time, with no memory of the one before. Three of the four zones below only make sense in an order, and the reading has no term for order. That is finding 4.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Indoor bath hall | Rest | 30 × 40 × 5 | south, 35% · valley | concrete · quartzite · quartzite | stone | grey · 3000 K |
| Sound Stone | Rest | 3 × 3 × 5 | none | concrete · quartzite · quartzite | stone | charcoal · 2700 K |
| Outdoor pool | Rest | 20 × 12 × 12* | south, 90% · valley | open sky* · quartzite · quartzite | stone | grey · 2700 K |
| Arrival passage | Move through | 2.5 × 40 × 2.6 | none | concrete · quartzite · quartzite | stone | charcoal · 2700 K |
* The outdoor pool has no ceiling and no fourth wall. The tool has no open rooms, a limit Sant Antoni's covered passage found first, so it is read as a tall box and the sound figure it returns is meaningless. Shown as run.
Six models per zone, weighted for a hotel. Read the material, colour and view columns; the rest are reporting on a building that is not there.
Below the demonstration library. Below Seattle. Two points below the Barcelona Pavilion's worst zone. If the number were a verdict the studio would have to argue that Therme Vals is a mediocre building, and the studio will not, because the number is not a verdict. It is the answer to six questions, and the questions that make this building are not among them. There is no model for water, none for temperature, none for steam, none for scent, and none for the way sound arrives when your ears are under the surface.
Every reading on this site carries that caveat in small type. This one is the reason to print it large. A method that will not say where it stops is a method that will eventually be used to condemn something it never measured.
There is a hollowed stone room at Vals that people step into and sing, because it rings. The sound model targets 0.4 to 0.7 seconds, which is the range for a room where you want to hear a person speak, and returns 0 for anything far above it. A room built to sustain a note is measured against a target for conversation and falls outside it.
The fix is a use, not a formula. The tool already knows the difference between rest, focus, gather, create and move through, and weights the six models accordingly. A sixth use, resonate, would invert the sound target instead of raising it, and would also cover a rehearsal room, a stairwell someone sings in and the Sagrada Família nave at the top of this page. That is the second time here that a missing use, rather than a missing model, produced a zero.
Five metres of height over a thirty-by-forty plate reads 0. Seattle's Mixing Chamber, 3.5 m over 40 m, also read 0, and the studio wrote it up there as the scale model's next fix: past roughly forty metres the visual-angle term sits on its threshold and the reading falls off a cliff rather than a slope. Two unrelated buildings, one a library and one a bath, hitting the identical edge is the point at which a limitation becomes a defect worth fixing rather than a caveat worth printing.
It matters here more than it did at Seattle, because at Vals the low ceiling over a wide floor is deliberate and is most of what the room feels like. The model is not merely blunt about it, it is pointed the wrong way.
You reach the baths along a dark stone corridor with no daylight and nothing to look at. The tool scores it as a failed room: no light, no view, a long reverberation, a total of 39. It is not a failed room. It is the instrument that empties your eye before the hall, and the hall works because of it.
The reading has no term for sequence. Each zone is read alone, as though a visitor arrived in it from nowhere, and a room whose whole value is what it does to the next room is invisible to that. Dimensions 04 and 08 read a plan for rhythm and for wayfinding; neither reads a plan for preparation, and this corridor is the clearest case the studio has found for a model that would.
The outdoor pool reads 90 on view, higher than anything at the Kimbell, Sant Antoni or Seattle. Ninety per cent of the field open, a planted edge, an Alpine valley beyond it. Ulrich's work is about exactly this, and nothing in the mapping had to be stretched to get there: the building really does hand a resting body a large, green, distant view, and the model really can read that.
Worth holding next to finding 1. The same instrument that produced a meaningless 44.3 across the scheme produced, in the same run, the single most trustworthy number in this section. That is what a partial instrument looks like from the inside, and it is why the readings are published model by model rather than as one score.
The sweep proposes slatted ceilings, textile walls, timber linings and heavy planting, for a gain of nearly seventeen points across the scheme. In a protected monument made of one stone, every one of those is a refusal, and the refusals are not close. Printed in full, as always.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Indoor bath hall | Heavy planting · slatted ceiling | 52 | 68 |
| Sound Stone | Heavy planting · timber walls | 28 | 48 |
| Outdoor pool | Heavy planting · textile walls | 59 | 70 |
| Arrival passage | Heavy planting · tiled ceiling | 39 | 59 |
Every row refused. Two of them, timber in the singing chamber and a tiled ceiling in the dark corridor, would destroy the exact effect the room exists to produce, which means the sweep is not merely over-eager here, it is inverted. A sweep that can propose the opposite of the brief needs a term for what the room is for beyond its five uses. That is the same specification finding 2 asked for, arriving from the other direction.
What it can show is where the instrument ends. Every other reading on this page found something about a building; this one found something about the tool, four times over, and each of the four came back with a specification attached. A method that only ever gets pointed at buildings it can already read never finds out what it is missing.
Nine square metres of burnt timber in a wheat field, twelve metres tall, lit by one hole in the roof. The best material reading on this page, and the worst for scale.
Open the chapel in the reading tool →Two zones, not four. The tool reads the oculus as no window at all. · Wikipedia →
images/research-bruder-klaus-light.jpg · 1920 × 1080Credit: Axel Kirch, CC BY-SA 4.0The construction is published in unusual detail because it was a hand build, and the dimensions are not, because it was a hand build.
Research card
Study 02 · Read
Every other building on this page was read as four zones because four is what it takes to describe a plan. This one has a chamber and the wedge you come in through, and inventing two more to fill the format would be dishonest. It is read as two, and the index says so.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| The chamber | Rest | 3 × 3.5 × 12 | none* | open sky* · charred timber · lead-tin | stone | charcoal · 2700 K |
| The entry wedge | Move through | 1.2 × 4 × 12 | none | open sky* · charred timber · lead-tin | steel door | charcoal · 2700 K |
* The oculus is the only opening and the tool cannot read it, so glazing is entered as none and the light readings come back 0. Corrected by hand, the chamber's daylight is a narrow, moving, very high-contrast patch, which is a condition the circadian model was not built for either.
Six models per zone, weighted for worship. Two of the twelve readings are the best of their kind on this page and two are the worst, which for a nine-square-metre room is a result in itself.
The raycast census sends sixty by thirty-six rays from a standing eye and asks what fills the visual field; the skin-response integral asks what the hand actually meets. In a room three metres across, 62% of the field is within reach and all of it is burnt timber, hand-poured metal or stone. Surround restorativeness comes back 0.82, which is the figure the model gives a room made entirely of natural material with nothing synthetic in it at all.
Zumthor has argued in prose for thirty years that material presence is the substance of architecture. This is that argument arriving from a ray census and an ordinal scale fitted to somebody else's experiment, which is the only kind of agreement worth having.
Twelve metres of height in a plan you can cross in four steps. It is the most extreme aspect ratio in the set by a wide margin, and the scale model scores it 0 through the shaft penalty, a term written to catch rooms that are tall because a service riser or a light well made them tall. This one is tall on purpose and the penalty cannot tell the difference.
That is the same shape of problem as the cathedral prime in the Sagrada Família reading at the top of this page, at the other end of the range. The scale model has a ceiling above which it stops distinguishing and a floor below which it stops forgiving, and Sagrada Família and Bruder Klaus sit one on each. Both are deliberate, both are read as faults. A term for whether the height is doing something, rather than only how much of it there is, is what both findings are asking for.
The Sagrada Família's lit vault crowns. The Kimbell's slit vaults. Seattle's roof glazing. This chapel's oculus, which is the only opening it has. Each was written up in its own section as a limitation of the tool, and each time the studio corrected the number by hand and moved on. Four in eight is the point at which that stops being reasonable.
The light model reads windows in walls because solar geometry against a vertical plane is the tractable case and it is what the field data was collected on. A rooflight needs a different integral and an honest treatment of the reflector or the vault under it. It is the largest single piece of work the reading tool is missing, and it took reading eight buildings nobody commissioned to establish that, which is the argument for reading them.
A twelve-metre shaft of hard material ought to ring. It does not, and the tool knows it does not: 1.17 seconds, clarity 37, a score of 72, the best sound reading on this page. The reason is that the mapping entered timber walls, and the walls are timber, charred, fluted by 112 trunks into a surface with far more area than its footprint suggests.
The accident is that the tool is reading a flat timber wall and getting the right answer for a corrugated burnt one. It would be wrong about why. That is worth writing down rather than claiming as a success, because the next building with a deeply modelled hard surface will get the same treatment and the accident will not repeat.
The sweep offers seven points for heavy planting, a tiled ceiling and wool at the hand. There is no ceiling to tile, the room is open to the weather, and the whole argument of the building is that there is nothing in it. Refused.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| The chamber | Heavy planting · tiled ceiling | 36 | 42 |
| The entry wedge | Heavy planting · wool at the hand | 55 | 62 |
The wedge's row is the more interesting refusal. Wool on a handle is the cheapest move the tool knows and it is right about it nearly everywhere else on this site. Here the thing your hand meets is a cold steel plate you have to lean on to open, and that weight is the first thing the building does to you. A move that is correct in most of the buildings on this page is still a move that has to be argued each time.
What it can show is that a nine-square-metre room can produce the best and the worst reading among the studio's first eight buildings at the same time, on two different models, and that neither number is a judgement of the chapel. One is the tool agreeing with the architect and one is the tool meeting the edge of its own range.
The Holocaust Tower scores 21, the lowest on this site, and every number is correct. Acting on it would be a serious mistake.
Open the museum in the reading tool →Loads the four zones as read here. Read finding 1 before you read the scores. · See the building → · Wikipedia →
images/research-jmb-zinc.jpg · 1920 × 1080Credit: Ansgar Wernst, CC BY-SA 4.0The building is described in the literature far more often than it is dimensioned, so the zones here lean harder on photographs than anywhere else on this page except the chapel.
Research card
Study 13 · Read
The four zones were chosen to put the building's extremes next to its ordinary floor, because the argument of this section is about what a low number means and you cannot make it without something normal in the frame. The exhibition floor is the control.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Holocaust Tower | Rest | 4 × 4 × 24 | none | concrete · concrete · concrete | steel door | grey · none |
| Memory Void | Move through | 4 × 17 × 20 | none | concrete · concrete · concrete | steel | grey · 3000 K |
| Garden of Exile | Move through | 15 × 15 × 6* | south, 90% · sky | open sky* · concrete · cobbles | stone | grey · 2700 K |
| Permanent exhibition | Gather | 20 × 40 × 4 | west, 12% · city | plaster · plaster · timber | laminate | white · 3000 K |
* The Garden is outdoors and is read as a box, the same wrong reading the Vals pool gets in its own reading, so its sound figure should be ignored. Its floor also slopes, and nothing in the tool knows that.
Six models per zone, weighted for a gallery. Every number below is correct. Finding 1 is about what follows from that, which is not what it looks like.
No daylight the model can use, 5.61 seconds of reverberation in a concrete shaft, a height-to-body ratio of 14.24, a material reading of 36 and nothing to look at. Five of the six readings are as bad as the models go, and every one of them is accurate. People stand in that room for a few minutes and come out changed, which is the entire brief, and the brief was to make a room that is hard to be in.
An instrument that returned 21 and stopped there would recommend demolishing the best thing Libeskind has built. The studio's rule, written on the purpose page and tested here: the reading says what the perceptual conditions are, not whether the architecture is good. Conditions and intentions are different measurements. This building separates them further than any other on this page, which is exactly why it is on it.
Concrete overhead, concrete on every wall, concrete underfoot, a steel door, and 63% of the visual field within reach. Surround restorativeness comes back 0.32, against 0.82 for the burnt-timber Bruder Klaus chapel. Same census, same integral, same scale, opposite ends of it.
This is the reading to point at when someone asks whether the models actually measure anything. Two small rooms, both hard, both dim, both made of one material, and the model separates them by half its range on the basis of which material. It is not detecting size or light or budget. It is detecting what the surfaces are, which is what it claims to do.
The Tower is 4 m square and scores 0. The Void is 4 m wide and 17 m long, which puts it the other side of the cathedral prime, and it scores 72. Both are bare concrete shafts around twenty metres tall that you enter through a heavy door and want to leave. The model puts seventy-two points between them.
The prime is a step function, and a step in the middle of a continuous quantity will always produce a pair like this eventually. Finding it required two nearly identical rooms in one building, which is not a condition you can arrange on purpose. Recorded as a defect in the scale model, alongside the wide-plate cliff that Vals and Seattle found twice.
Forty-nine pillars on ground sloping about twelve degrees, planted above head height, open to the sky. The tool sees a December dose of 0.57, a view reading of 59 and a total of 61, the highest in the building, and it is not wrong about any of that. What it cannot see is the floor, which is the whole device: visitors report disorientation, and the ground is the reason.
There is no term anywhere in the six models for a floor that is not level, because every room the tool has been pointed at had a flat one. A slope term would also read a ramped foyer, a raked auditorium, a sloping street entrance and half the ground floors in Barcelona. This garden is where to write it.
A facade of slashes comes to about 12% glazing, and the December dose lands at 0.19. That is not a dramatic number and it is not meant to be: it is close to the winter shortfall measured at real desks in real offices, which is the field data the light model is calibrated against. The room works in summer and runs on electric light from November to February.
It was the last of the studio's first eight readings, and the right one to end that set on. Seven extraordinary rooms produced seven findings about the limits of the instrument. This one, an ordinary gallery floor with small windows in a northern city, produced the finding the instrument was built for, on the first attempt, with nothing corrected by hand. That is what the tool is for. The other seven are how you find out what it still needs.
The sweep offers twenty points across the scheme for textile walls, wool at the hand and heavy planting. In the Tower and the Void those moves would delete the building. On the exhibition floor, which is an exhibition floor, most of them are ordinary and some are overdue.
| Zone | Move | Now | After |
|---|---|---|---|
| Permanent exhibition | Absorbent ceiling · planting at the rest points | 55 | 75 |
| Garden of Exile | Left as built · the planting is the artwork | 61 | 61 |
| Memory Void | Refused · textile and wool in the Void | 38 | 38 |
| Holocaust Tower | Refused · every move deletes the room | 21 | 21 |
The exhibition floor's twenty points are real and cheap: 3.6 seconds of reverberation on a gallery floor at eighty people is a room where nobody can hear a guide, and an absorbent ceiling is the least invasive fix in the whole toolkit. The three refusals above it are not close calls, and the studio would put them in writing before starting, because a sweep left running unsupervised would have proposed all four.
What it can show is the difference between a measurement and a judgement, held apart under the hardest possible conditions. Every number in this section is right. Acting on any of the first three zones would be indefensible. Both of those sentences have to be true at once for the method to be worth anything, and this is the building that makes you say so.
A forest of three thousand trees under a glass dome. The best view on this page, and an echo that the trees and a 40 m waterfall change completely.
Open Jewel in the reading tool →Loads the four zones as read here. The dome's sound reading is a sealed box; finding 1 is why. · See the building → · Wikipedia →
images/research-jewel-forest-valley.jpg · 1920 × 1080Credit: Mike Peel, CC BY-SA 4.0The big figures are published and round. The rooms inside them are not published at all, so every zone below is scaled.
Research card
Study 03 · Read
Everything under the glass shares one volume of air, so the dome is read once as a whole room and then again as a trail through the forest. The shops that ring its edge are a different kind of room: lower, air-conditioned, looking in. Below them are floors that see neither sky nor forest. The section is schematic; the width, the fall of the Vortex and the figure are to scale.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| The Rain Vortex floor | Gather | 150 × 200 × 40 | south, 90%* · trees | glass* · glass* · stone | steel rail | sage · 6500 K |
| Forest Valley trail | Move through | 60 × 6 × 30 | south, 90%* · trees | glass* · glass* · stone | steel rail | sage · 6500 K |
| Retail ring | Move through | 80 × 10 × 5 | north, 40% · trees | plaster · plaster · stone | steel rail | white · 4000 K |
| Basement retail floor | Move through | 60 × 40 × 4.5 | none | plaster · plaster · stone | steel rail | white · 4000 K |
* The dome is all glass and mostly roof. The tool reads glass in walls only, so the dome's light is entered as a 90% glazed south wall, and its glass surfaces are entered as concrete, the nearest hard surface the sound model has. At 1.36°N the choice of cardinal barely matters.
Six models per zone, weighted for transport, the nearest type the tool has to an airport's front garden. Every zone scores 0 on sound, and the reason is different in the dome and in the basement.
Read as a sealed box of hard surfaces, 1.2 million cubic metres of air under glass rings for 61 seconds. No room does that, and this one does not either. The sound model knows planting only as something to look at. Counted by hand as what it also is, about 22,000 m² of leaves and soil absorbing somewhere between 30% and 70% of the sound that reaches it, the figure falls to between 8 and 20 seconds, depending on the absorption and on how much smaller the real dome is than a box.
That is still long, and it is still the wrong question. Under this dome there is always a sound, 40 metres of falling water, and a steady sound like that covers the voices and footsteps a long decay would otherwise smear. The engineers say they tuned the acoustics so the water calms. The tool measures how long a sound lasts and has no term for what is making it. Sant Antoni's open ends, Seattle's shelving, and now a forest: the third time a real building has shown the sound model an absorber it cannot count.
The Bruder Klaus reading counted four of the studio's first eight buildings lit by something the light model does not read. Jewel, the ninth read, makes it five of nine, and it is the purest case: nine thousand panels of glass, nearly all of it overhead. The December dose of 0.69 in the table is from a stand-in, the dome's side read as a glazed wall, and it clears the threshold easily, as almost anything would at 1.36°N.
Near the equator the model's own question goes soft as well. It asks whether a room gets enough light in the darkest month, and in Singapore December and June differ by little. The real questions here are heat, glare and whether 3,000 trees get enough light to live, and none of them is a question the tool asks.
The view model multiplies how much of the field of view is outside the room by what is in it, with planting counted in, after Ulrich's 1984 window study and later work on natural views. Under the dome every direction is trees, and both zones score the maximum, the first 100 on this page. The ring of shops, which looks into the forest across a balustrade, still scores 83.
What the model cannot do is tell a forest from a planted atrium, or know that the benefit Ulrich measured was for patients recovering from surgery, not for travellers with a flight to catch. It confirms that the view is there. Whether the view does what biophilic design says it does, for these people, is a question for a study with people in it.
The Forest Valley and the Canopy Park together are about 36,000 m² of a published 135,700 m², about a quarter. The rest is shops, restaurants, a hotel and airport facilities, and the floors below ground see neither sky nor forest. Read as one of those floors, the building scores 30: no daylight, a view of 18, and the same four seconds of reverberation as any hard-finished mall.
This is not a criticism of the forest. It is the reminder that a building is judged by its photograph and lived in by the square metre. Most of the people in Jewel at any moment are not standing under the glass.
The sweep offers twenty-five points across the scheme. Under the dome it proposes textile walls, on a wall made of glass, and wool at the hand, on balustrades that 300,000 people a day hold. Both refused. The basement row is the one worth taking to a client.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| The Rain Vortex floor | Wool at the hand | 56 | 60 |
| Forest Valley trail | Wool at the hand · textile walls | 57 | 86 |
| Retail ring | 2700 K lamps · heavy planting · wool at the hand · slatted ceiling | 54 | 86 |
| Basement retail floor | 2700 K lamps · heavy planting · wool at the hand · slatted ceiling | 30 | 66 |
Warmer lamps, an absorbent ceiling and planting on the floors that cannot see the forest would bring a little of the dome down to the people who are not under it. The wool is refused everywhere: in a building this busy the hand needs a surface that can be cleaned, not a soft one. The trail's twenty-nine points are the tool asking to line a glass dome with fabric.
What it can show is an instrument meeting a building whose main materials are water, leaves and glass, and getting the one of the three it was built for, the view, exactly right. The other two it reads as concrete. That is the most useful sentence in this section, because it names the next two things the tool needs.
A concrete box with a cross cut into the wall behind the altar. The sun draws the whole cross in light on spring and summer mornings, and never in December.
Open the church in the reading tool →Two zones, as with the Bruder Klaus chapel. The cross wall faces east, as published. · See the building → · Wikipedia →
images/research-church-light-cross-full.jpg · 1600 × 900Credit: Bergmann, CC BY-SA 3.0The box is published to the centimetre. Almost everything else about the room is in the photographs, not in the drawings.
Research card
Study 04 · Read
The chapel is one volume and the way in is a narrow slot beside the angled wall, so it is read as two zones, as the Bruder Klaus chapel was. The drawings go further than the zones: they follow the sun through the cross, because the cross is the building.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| The chapel | Gather | 5.9 × 11.8 × 5.9 | east, 7% · blank | concrete · concrete · timber | oak | grey · 3000 K |
| The way in | Move through | 1.8 × 11 × 5.9 | none | concrete · concrete · concrete | steel | grey · 3000 K |
The cross is the only opening in the chapel and it is read as 7% of an east wall. The way in has no window of its own and reads as none.
Six models per zone, weighted for worship. The chapel is dark by design and the tool scores it as a dark room; the way in is darker still.
Each arm of the cross is a slot through 38 cm of concrete, and a slot only passes direct sun while the sun is nearly square to it. With slots 0.2 m wide, the vertical arm sees the sun only within 27.8° either side of due east. The March and June sunrises are inside that arc, and the whole cross lands in sunlight for about 129 and 133 minutes. The December sun rises at 120°, outside it, and never comes back: the vertical arm carries no direct sun at all, and only the horizontal arm is lit.
The slot width is scaled from photographs, so the result is given with its range: at 0.15 m the December cross never forms, at 0.25 m it forms for 28 minutes. Either way, the cross of sunlight is a spring and summer event, and in winter the cross is seen only as a glowing opening, not as light on the floor.
At sunrise the light through the horizontal arm lands high on the back wall, behind the congregation. As the sun climbs it drops to the floor and moves up the aisle towards the altar: 9.2 m from the east wall at 07:30 solar time, 6.8 m at 08:00, 6.1 m at 08:12. Then the sun rises past 27.8° in profile and the depth of the wall cuts it off.
So the morning light travels towards the altar and never reaches it. Whether Ando meant that, the drawing cannot say. That it happens every clear spring morning, it can.
Averaged over the working day, the cross gives the chapel 0.15 in December, half of what the circadian model wants for a body, and the light reading comes back 54. Every part of that is correct and none of it is useful: a room lit to the model's threshold would lose the cross. It is the position the Jewish Museum reading reached with the Holocaust Tower, a number that is right and a change that would be indefensible.
The sweep offers heavy planting and a slatted ceiling in the chapel, and wool and timber walls on the way in. In a room made of one material and one opening, all of it is refused.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| The chapel | Heavy planting · slatted ceiling | 50 | 70 |
| The way in | Heavy planting · wool at the hand · timber walls | 33 | 62 |
A slatted ceiling would shorten the reverberation, which the tool wants, and flatten the singing, which the congregation does not. Planting in front of the cross is not a move anyone should make.
What it can show is a tool that is right about a room in every number and wrong about what the room is for. It is the clearest case on this page of why a reading has to be read by someone.
A museum that is mostly a walk through a park. Its glass corridor is the best room on this page; a closed gallery is one of the worst.
Open Louisiana in the reading tool →Loads the four zones as read here. The corridor's height is scaled, and finding 1 shows how much it matters. · See the building → · Wikipedia →
images/research-louisiana-glass-corridor.jpg · 1920 × 1080Credit: kallerna, CC BY-SA 4.0The history is published in detail. The rooms are not dimensioned in anything public, so every zone is scaled from photographs.
Research card
Study 14 · Read
The reading follows a visit: the corridor, a gallery that looks out, a gallery that does not, and the café by the water. The dimensions are scaled from photographs, and the corridor's height is the one that matters most.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Glass corridor | Move through | 30 × 3 × 2.6 | west, 90% · trees | timber · plaster · stone | oak | white · 3000 K |
| Giacometti gallery | Gather | 10 × 12 × 5 | north, 50% · trees | timber · plaster · stone | oak | white · 3000 K |
| South Wing gallery | Gather | 20 × 30 × 4.5 | none | plaster · plaster · stone | oak | white · 3000 K |
| Café over the sound | Gather | 15 × 10 × 3 | east, 70% · sky | timber · plaster · stone | oak | white · 2700 K |
The sea is entered as sky, the nearest view the tool has. The South Wing gallery is read as closed; if it has rooflights, the tool could not see them in any case.
Six models per zone, weighted for a gallery. The two zones that look out score 83 and 79; the two galleries score 58 and 42.
Light 99, sound 83, scale 88, material 90, view 100. At the height scaled from photographs, 2.6 m, the ceiling sits at 1.55 median bodies, the comfortable ratio dimension 09 derived. Every model agrees about it, and it is the highest zone on this page.
The honest caveat is in the stat: the height is scaled, and the scale reading is steep near that ratio. At 2.4 m the corridor totals 73; at 2.8 m, 85. The drawing shows why: the scale reading is 88 at 2.6 m, 41 at 2.4 m and 17 at 2.3 m, and it is already 100 by 2.8 m. Thirty centimetres of ceiling is the difference between the best room on this page and an ordinary one, and the corridor sits on exactly that slope. It stays the highest zone here anywhere in the range, but the exact figure is only as good as the photograph it came from.
The gallery is read with a north window, and in a Danish December it passes 0.07, a quarter of what the model wants for a body. The model is right about the body, and its threshold is written for people who spend a working day in a room.
A visitor passes through in minutes, and a gallery often keeps daylight low on purpose. The number describes the room correctly and the target does not fit the use, which is a gallery-weighting question the tool has not been asked before.
Read with no window, hard plaster and stone, the South Wing gallery gives 5.37 seconds of reverberation, no daylight, and a view of 18. It was built in 1982 for larger works, and large works need walls and control of light, which is a real reason.
The tool cannot weigh that reason. What it can show is how much of what visitors say about Louisiana is the corridor and the park, and how little of it is any single gallery.
The sweep proposes 6500 K lamps and magnolia paint everywhere, textile walls in the Giacometti gallery, and carpet in the café. The lamp and wall colours are the curators' decisions, not the tool's.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Glass corridor | 6500 K lamps · magnolia walls | 83 | 85 |
| Giacometti gallery | 6500 K lamps · magnolia walls · textile walls | 58 | 76 |
| South Wing gallery | 6500 K lamps · heavy planting · magnolia walls · slatted ceiling | 42 | 63 |
| Café over the sound | 6500 K lamps · heavy planting · magnolia walls · carpet | 79 | 87 |
The one move worth a conversation is an absorbent ceiling in the closed galleries, which would bring 5.37 seconds down to a room people can talk in without changing a wall the art hangs on. The rest is the tool redecorating a museum.
What it can show is that the highest reading on a page of famous buildings belongs to a corridor. That is a finding about Louisiana, and also about what these six models value: light, a view out, a ceiling at body height, and something warm to touch.
Two concert halls, read by a tool built for speech, and a foyer facing the sun, because in Sydney the sun is in the north.
Open the Opera House in the reading tool →Loads the three zones as read here. The halls are scaled boxes; finding 1 says what that does to the sound. · See the building → · Wikipedia →
images/research-sydney-interior.jpg · 1920 × 1080Credit: Larry Koester, CC BY 2.0The building is published in great detail. The halls' volumes are not given in any source the studio checked, so they are scaled.
Research card
Study 06 · Read
The two main halls are read as full, as they are when they matter. The foyer is read at an interval, with four hundred people in it. The halls are scaled boxes; the real volumes are shaped by the shells and are smaller.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Concert Hall | Gather | 45 × 60 × 25 | none | timber · timber · timber | wool | oak · 3000 K |
| Joan Sutherland Theatre | Gather | 30 × 35 × 18 | none | timber · timber · timber | wool | oak · 3000 K |
| Northern foyer | Gather | 40 × 20 × 20 | north, 90% · sky | concrete · concrete · stone | steel | cream · 3000 K |
The halls have no windows. The foyer faces north, the sun side in the southern hemisphere, and the tool reads June as its winter.
Six models per zone, weighted for a gallery because the tool has no type for a performance venue. Both halls come back 38 for the same two reasons.
The tool has one target for a gathering, 0.6 to 0.9 seconds, which is the right target for a lecture. A symphony hall is designed to ring for far longer than that, so a hall that met the tool's target would be a failed concert hall. The 4.96 seconds here is also an upper bound, because the hall is read as a box larger than the room under the shells.
The drawing puts a number on how wrong the box is: with the same timber and the same audience, the hall would ring for two seconds at about 20,500 m³, less than a third of the box. The one thing the tool and the building agree on is the direction. The 2022 renewal added absorbent hangings to reduce reverberation. The tool would have asked for that too, and for a much larger amount, which is exactly why it needs a target for music before it reads another hall.
Every other building on this page is in the northern hemisphere, where a north window is the dim one. Here the foyer's glass faces north into the sun, and the model reads June as winter. It gives 0.66, more than twice the threshold, and a light score of 100. The section shows what that means in the room: at noon on 21 June the sun stands at 32.7° and crosses all twenty metres of the foyer to the back wall; on 21 December it stands at 79.6° and gets 3.7 m in. The glass lets the winter in and keeps the summer out, without a single shading device.
It is worth saying because it is the first time the page has tested that part of the model on a real building, and it passed.
Both halls lose their light and view readings because they have no windows, which is correct for a hall, and their sound because the target is for speech. Weighted as a gallery, which is the nearest type the tool has, that is enough to put two of the best-known halls in the world at 38.
The tool needs a performance type, with no weight on daylight or view and a music target for sound. Until then its totals for halls should not be published without this paragraph, so this paragraph is published.
The sweep proposes 6500 K lamps, heavy planting and magnolia walls in both halls, and wool at the hand in the foyer. All of it is refused.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Concert Hall | 6500 K lamps · heavy planting · magnolia walls | 38 | 48 |
| Joan Sutherland Theatre | 6500 K lamps · heavy planting · magnolia walls · textile walls | 38 | 59 |
| Northern foyer | 6500 K lamps · heavy planting · wool at the hand | 52 | 64 |
The building's own renewal is the better answer than anything the sweep has: acoustic work designed by specialists, tested with musicians, and reversible where it can be. The tool would have painted the birch.
What it can show is the same honest failure the Sagrada Família showed at the top of the page, now in its purest form: an instrument built for rooms people work in, reading rooms built for music, and returning precise numbers that should not be used.
A waste-to-energy plant with a ski slope on its roof. Most visitors are outside on the slope, and its clean energy is a separate question from how it feels.
Open CopenHill in the reading tool →Loads the three zones as read here. The slope is outdoors and is read as a box; finding 2 is why that figure is set aside. · See the building → · Wikipedia →
images/research-copenhill-facade.jpg · 1920 × 1080Credit: kallerna, CC BY-SA 4.0The plant is published as a plant: tonnes, megawatts, metres of height. Its interiors are not, so the zones are scaled.
Research card
Study 15 · Read
The plant is read once for the people who work in it, the bar for the people who come for the view, and the slope for the people who come to ski. Only the bar is the kind of room the tool was built for.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Boiler hall | Create | 40 × 100 × 60 | west, 30% · built | concrete · concrete · concrete | steel | grey · 4000 K |
| Rooftop bar | Gather | 20 × 15 × 4 | west, 80% · sky | timber · timber · timber | oak | oak · 2700 K |
| Ski slope | Move through | 60 × 400 × 20 | south, 90% · sky | concrete · concrete · concrete | steel | grey · 6500 K |
The slope is outdoors. It is read as a box because the tool has no outdoors, and its sound reading is meaningless. The boiler hall's occupancy is a guess.
Six models per zone, weighted for a campus, the nearest type the tool has. The bar is the one zone the readings describe well.
Sixty metres of concrete and steel read as a box gives 76 seconds, the longest figure on this page. It is also the least useful: in a working hall the question is the noise of the machines, and the tool reads how long a sound lasts, not what is making it.
Jewel's waterfall made the same point from the other side. Twice now, the loudest thing in a building has been a source the tool does not have.
A hillside open to the sky cannot ring for fifty-five seconds, and the tool says it does because it can only read a room. The Garden of Exile at the Jewish Museum was the first outdoor zone read as a box on this page; this is the second, and the more important, because it is where most of CopenHill's visitors are.
The other readings for the slope, light 100 and view 69, are reasonable because they do not depend on walls. Sound and scale do, and both are printed here only to show what the tool does when it meets an outside.
CopenHill is known as a clean waste-to-energy plant that gives the city a park. The six models read light, sound, scale, material, colour and view. None reads energy, emissions or carbon, so the building's main claim is invisible in every number above. The second drawing shows what that claim is, from the published figures alone: up to 247 MW of heat and 63 MW of electricity from about 400,000 tonnes of waste a year. Four fifths of it is heat for the city, which is a fact about how Copenhagen lives in winter and not about any room in this building.
This is the gap the studio's own Pillars page names: sustainable design is the thinnest of the four pillars, with no dimension of its own yet. A building like this is the argument for building one.
The sweep proposes warm lamps, planting and wool in the boiler hall, and wool on the slope. Both refused. In the bar it proposes daylight lamps, planting and a slatted ceiling.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Boiler hall | 2700 K lamps · heavy planting · wool at the hand | 44 | 55 |
| Rooftop bar | 6500 K lamps · heavy planting · slatted ceiling | 73 | 88 |
| Ski slope | 2700 K lamps · wool at the hand | 56 | 63 |
The slatted ceiling in the bar is the only move here worth a conversation: 1.75 seconds of reverberation in a room of eighty people is loud, and timber slats fit the room. The rest is the tool furnishing a machine and carpeting a hill.
What it can show is the edge of a perceptual tool. It can say that the bar is a good room and the machine hall is a hard one. It cannot say whether CopenHill is a good building, because what makes it one is outside all six models.
A concert hall behind coloured glass at 64° north. Its glass foyer gets almost enough winter light, from about four hours of December sun.
Open Harpa in the reading tool →Loads the three zones as read here. The coloured glass reads as clear; finding 2 is why. · See the building → · Wikipedia →
images/research-harpa-foyer-stair.jpg · 1920 × 1080Credit: Marcos H. Mujunen, PexelsSeat counts and the building's size are published. The halls' dimensions are not, so they are scaled.
Research card
Study 08 · Read
The foyer is the space the façade makes, and it is read once, at an interval. Behind it the main hall and the smallest hall are read full. The halls are scaled boxes.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Eldborg | Gather | 30 × 40 × 25 | none | timber · timber · timber | wool | oak · 3000 K |
| Foyer behind the glass | Gather | 60 × 20 × 30 | south, 90% · sky | concrete · concrete · stone | steel | charcoal · 3000 K |
| Kaldalón | Gather | 15 × 20 × 8 | none | timber · timber · timber | wool | oak · 3000 K |
The halls have no windows. The foyer is entered as a 90% glazed south wall; the glass is coloured, and the tool reads it as clear.
Six models per zone, weighted for a gallery, the nearest type the tool has. The halls score like the Opera House's halls, for the same reasons.
In a Reykjavík December the sun is up for about four hours, low in the south, and the first drawing shows how low: never above 2.4°. The foyer is almost all glass, and the model gives it 0.28, just under the threshold of 0.30. That is a large amount of light for the latitude, and it comes from building a room that is nearly all window.
The model averages 09:00 to 17:00, so the hours before sunrise and after sunset count as darkness, which they are. The number is fair to the room and to the place. What it misses is where that light goes: at 2.4° it does not fall on the floor at all. It crosses the room almost level and lands on the back wall, coloured by the glass it came through, which is the second drawing and the building's real winter event.
The colour model multiplies a wall colour by a lamp temperature. Eliasson's façade colours the daylight itself, the same condition the Sagrada Família reading named as the colour model's next case to build. Harpa is the second building on this page where the main colour event is in the glass.
Two is enough to make it a pattern. The seventh input the Sagrada Família reading proposed, the spectrum of arriving light, would read both.
The same problem as the Opera House: the tool's target for a gathering is set for speech, and a concert hall is designed to ring longer. Eldborg comes back 3.79 seconds as a scaled box and Kaldalón 1.98, and both lose their sound reading.
Four halls on this page now ask for a music target. The case for it no longer needs making.
The sweep proposes daylight lamps, planting, magnolia paint and textile walls in both halls, and planting and wool in the foyer. All of it is refused.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Eldborg | 6500 K lamps · heavy planting · magnolia walls · textile walls | 38 | 57 |
| Foyer behind the glass | Heavy planting · wool at the hand | 56 | 61 |
| Kaldalón | 6500 K lamps · heavy planting · magnolia walls · textile walls | 44 | 64 |
Painting Eldborg magnolia would remove the one thing everyone remembers about it. The tool has no reason to know that, which is why a sweep is a list of options and not a list of recommendations.
What it can show is a building that answers its latitude with glass, and a tool that can measure how well it worked. That part it gets right. The colour and the music it cannot hear or see.
A visitor centre shaped like an orchid, with a planted roof. It scores well for material and view, badly for sound, and one ceiling change fixes it.
Open the visitor centre in the reading tool →Loads the three zones as read here. The oculus is a rooflight and the tool cannot see it; finding 1. · See the building → · Wikipedia →
images/research-vandusen-oculus.jpg · 1920 × 1080Credit: Daderot, CC0The building is published mostly for its systems. The rooms are not dimensioned in public sources, so they are scaled.
Research card
Study 07 · Read
The atrium under the oculus is the centre of the building, the café faces the garden, and the library is the one room for sitting still. The dimensions are scaled from photographs.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Atrium under the oculus | Gather | 20 × 20 × 7 | south, 40% · trees | timber · lime · concrete | oak | beige · 3000 K |
| Café | Gather | 15 × 10 × 4 | west, 60% · trees | timber · lime · concrete | oak | oak · 3000 K |
| Library | Focus | 8 × 8 × 3.5 | north, 30% · trees | timber · lime · concrete | oak | oak · 3000 K |
The oculus cannot be read, so the atrium's daylight is entered as a 40% glazed south wall. Rammed earth is entered as lime.
Six models per zone, weighted for a campus. Material and view are strong everywhere; sound is weak everywhere.
The solar chimney and its oculus are both the building's light and its ventilation. The light model reads windows in walls, so the atrium's daylight is a stand-in, a south wall glazed at 40%, and the December dose of 0.58 describes the stand-in.
That makes six buildings on this page, of sixteen, lit partly by something the light model cannot see. It remains the largest single thing the tool is missing.
Material 85 and view 93 in the atrium: the eye meets earth, timber and garden. Sound comes back 0 at 4.07 seconds, because rammed earth, glulam and concrete reflect nearly everything. The finishes that make a building read as natural are, acoustically, the same as concrete.
It looks like a trade-off between two of the studio's own pillars, biophilic material and a room people can talk in, and the second drawing tests it. Of twenty-five wall and ceiling combinations, the ones that fix the sound all change the ceiling. Keep the earth walls, make the timber ceiling slatted instead of solid, and reverberation falls from 4.07 to 1.36 seconds while the material reading moves by one point. The conflict is real, and it is one surface wide.
Like CopenHill, this building is known for systems the six models do not read. Its geothermal boreholes, photovoltaics, solar hot water and water treatment are invisible in every number above.
Two buildings on this page are now famous mainly for sustainable design, and the tool has nothing to say about either. That is the thinnest pillar, stated twice.
The sweep proposes 6500 K lamps everywhere, textile walls in the atrium and the library, and a slatted ceiling in the café.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Atrium under the oculus | 6500 K lamps · textile walls | 65 | 84 |
| Café | 6500 K lamps · slatted ceiling | 77 | 92 |
| Library | 6500 K lamps · heavy planting · textile walls | 52 | 76 |
The slatted ceiling in the café is the one to take: it is timber, it fits the room, and it answers the sound. The textile walls would cover the rammed earth, which is the point of the building, so absorption in the atrium would have to come from the ceiling. The lamps stay at 3000 K.
What it can show is the most useful conflict on this page: a building whose natural materials are exactly what make it loud. That is a question for the next thread, not a criticism of the building.
A 632 m tower in two skins of glass. Its ordinary office floor is its best room; the sky garden between the skins echoes for fifteen seconds.
Open the tower in the reading tool →Loads the four zones as read here. Every zone is "high" to the tool, at any height; finding 3. · See the building → · Wikipedia →
images/research-shanghai-tower.jpg · 1920 × 1080Credit: Stefan Fussan, CC BY-SA 3.0The tower is published in round figures. The rooms inside it are not, so every zone is scaled.
Research card
Study 09 · Read
The reading takes one room from each kind of space the tower has: where people work, the garden between the skins, the top, and the windowless lobby every journey passes through.
| Zone | Use | W × D × H | Glazing | Ceiling · Walls · Floor | Touched | Colour · Light |
|---|---|---|---|---|---|---|
| Office floor | Focus | 40 × 12 × 3.2 | east, 90% · built | tile · plaster · carpet | laminate | white · 4000 K |
| Sky garden atrium | Gather | 30 × 8 × 55 | south, 95% · sky | concrete · concrete · stone | steel | white · 4000 K |
| Observation deck | Gather | 40 × 40 × 5 | south, 95% · sky | plaster · plaster · stone | steel | white · 4000 K |
| Lift lobby | Move through | 10 × 6 × 4 | none | plaster · concrete · stone | steel | grey · 4000 K |
All four zones are entered at the tool's highest floor band, which it uses for anything above a few storeys.
Six models per zone, weighted for an office. The office floor reads best, and the sky garden, the tower's signature, reads worst on sound.
An acoustic tile ceiling, carpet and a hundred people give 0.46 seconds, inside the band for focused work, and a sound score of 100. The office floor totals 71, the best zone in the tower. Nothing about it is unusual, which is the finding.
Commercial office fit-out has spent decades solving exactly the problems these models measure. The rooms that read worst on this page are the ones designed to be remembered.
Between two skins of glass, fifty-five metres tall, the atrium rings for 15.6 seconds. The planting counts toward the view and not toward the sound, the same gap Jewel exposed at a much larger scale.
The atria are where the tower is meant to feel human. As read, they are the loudest rooms in it.
The floor band sets how much sky a window sees, and "high" is the highest band there is. It is right for the light. It says nothing of what five hundred metres does to a body: sway, pressure in the ears, the edge.
None of those is in any of the six models, and neither is the view itself: from near the top the horizon is about 87 km away, eight times as far as from a street window, and the tool reads it as sky, the same as any rooftop. For almost every building the studio will be asked to read, they will not need to be. For this one they are part of the experience, and the reading is honest only if it says so.
The sweep proposes warm lamps, heavy planting and wool at the hand everywhere, textile walls in the atrium, a slatted ceiling on the observation floor and carpet in the lobby.
| Zone | What the sweep proposes | Now | After |
|---|---|---|---|
| Office floor | 2700 K lamps · heavy planting · wool at the hand | 71 | 81 |
| Sky garden atrium | 2700 K lamps · heavy planting · wool at the hand · textile walls | 56 | 78 |
| Observation deck | 2700 K lamps · heavy planting · wool at the hand · slatted ceiling | 53 | 82 |
| Lift lobby | 2700 K lamps · heavy planting · wool at the hand · carpet | 41 | 60 |
Planting and warmer light in the windowless lobbies and an absorbent ceiling over the observation floor are ordinary, reversible moves. Textile walls in the atrium are not: the atrium is glass on both sides. Wool at the hand is refused, as in every busy building on this page.
What it can show is a tower whose ordinary floors are good rooms and whose special spaces are hard ones. That is the opposite of how towers are usually photographed, and it is the kind of thing a reading is for.